Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PINGUINO PAC GSR. We hope that this DELONGHI PINGUINO PAC GSR user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI PINGUINO PAC GSR.
Manual abstract: user guide DELONGHI PINGUINO PAC GSR
Detailed instructions for use are in the User's Guide.
[. . . ] - The Pinguino should not be installed where the atmosphere could contain combustible gases. - Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat. - Before moving the air-conditioner, empty water from collection tray. - Do not place hot or heavy objects on the appliance. [. . . ] The internal unit must be perfectly leveled. If necessary, use the castor stops supplied with the machine. The air intake and outlet grilles should not be obstructed in any way.
The external unit can be installed above or at the same level as the internal unit, provided that the difference in height between the two units does not exceed 1. 5 m. The intake and outlet vents must not be obstructed. between the rear of the unit and the wall. CONDENSATION DRAINAGE The condensation which forms when the unit is used for air-conditioning (i. e. in summer) evaporates from the external unit. If the humidity is particularly high, it may be necessary to fit the condensation discharge tube (supplied with the machine). In this case, fit the hose to the coupling on the bottom section of the external unit (remove the rubber cap from the coupling). When specific applications require it, the condensation drainage can be done directly from the discharge pipe on the back of the unit. Should this happen, water will be collected into a tank and automatically removed through a pump system. Such a pump has to be installed separately and is available at any air conditioning contractors in your area.
EXTERNAL UNIT
The external unit can be positioned on a terrace or balcony. In this case, it is not
necessary to use the fixing brackets. The external unit can also be mounted on a wall.
334 mm
Rubber cap Ring
Coupling
249 mm
8
ELECTRICAL CONNECTIONS
Before plugging the unit into the power supply, check the following: · the power supply voltage must be the same as the voltage shown on the rating plate · the power socket and the voltage circuit must be suitable for the power requirements of the unit · the socket must be suitable for the plug; if not, have the socket replaced.
· · ·
Do not place objects of any kind on the airconditioner. Ensure that the air intake and discharge vents are not obstructed. Make sure that there are no sources of heat in the room.
FINAL CHECK
In order to ensure that your air-conditioner operates with the maximum efficiency, make sure that: · all doors and windows in the room to be airconditioned are closed (except for temporary installation, in which case a window must be left partially open).
Close the door
Close the windows · Draw the curtains and/or partially close the blinds to protect the room against direct sunlight. This will increase the efficiency and economy of the air-conditioner.
Lower the blinds
Do not cover Draw the curtains YOUR AIR-CONDITIONER IS NOW READY FOR USE
9
CONTROL PANEL
TIMER ON signal lamp "Alarm" warning light "Fan" signal lamp "Air-conditioning" signal lamp
1 2
O I
OFF
4 5
6
MIN
Min. airconditioning signal lamp
3
ON
7
MAX
A
B
C
D
Timer notches
Thermostat knob ON/OFF main switch key Timer key
Fan speed selection key Fan/conditioning selection key
SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4:00 p. m. , turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 (4 p. m. ) is lined up with the arrow pointer (the arrows indicates 4:00 p. m. PROGRAMMED MODE 1) Release timer button B . 2) Set the operating times by pushing out the notches on the dial corresponding to the period required (each notch represents 15 mins. ). 3) Check that the timer indicates the correct time (see instructions on setting).
Funzionamento Operating time
11
10
9
eg. [. . . ] Park 80 West Plaza One, 4th floor
GARANTIE
Nous garantissons que tous les appareils électriques DE'LONGHI sont exempts de tout défaut de matériaux et de manufacture. Notre obligation sous cette garantie est limitée au replacement ou à la réparation, gratuit en notre usine, de toutes les pièces défectueuses autres que les pièces endommagées durant le transport, qui nous seront retournées transport payé d'avance - endèans un an après la livraison à l'acheteur-utilisateur. Cette garantie ne sera applicable que si l'appareil a été utilisé selon les instructions du fabriquant qui accompagnament l'appareil, et sur courant alternatif (AC). Cette garantie remplace toutes autres garanties et représentations, exprimées ou impliquées, et toutes autres obligations ou responsabilités de notre part. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PINGUINO PAC GSR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PINGUINO PAC GSR will begin.