If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PINGUINO PAC290. We hope that this DELONGHI PINGUINO PAC290 user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI PINGUINO PAC290.
Manual abstract: user guide DELONGHI PINGUINO PAC290
Detailed instructions for use are in the User's Guide.
[. . . ] - The Pinguino should not be installed where the atmosphere could contain combustible gases. - Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat. - Wait at least 3 minutes before restarting, after the air-conditioner has been switched off or the thermostat setting changed. - Before moving the air-conditioner, remove tank and empty water from collecting tray (see instructions for drainage at page 12). [. . . ] Important: if you need to use and extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of the Pinguino (Fig. 9
FINAL CHECK
In order to obtain the maximum performance from your air-conditioner make sure that:
fig. 10
-
Doors and windows of room to be airconditioned are closed (with the exception of temporary installation where a partially opened window is necessary).
fig. 13
-
Shade the room as far as possible from direct sunlight by drawing curtains and/or lowering blinds or shutters, for economical and efficient air-cooling.
-
Ensure that intake and outlet vents (fig. Make sure there are no sources of heat in the room.
SPECIAL NOTE
This machine is designed to be used with or without water. Maximum performance is obtained using water. When used without water, Pinguino will maintain a full 88% of its cooling capacity.
HOW TO PREPARE WATER CONTAINER
Use only clean, salt-free tap water. The water is essential for the air cooling operation and si discharged in the form of steam through the exhaust outlet. A container full of water lasts for a period that depends on a number of conditions such as temperature, humidity, insulation, exposure of the room, number of people present, etc. On average it will last approximately 7 to 10 hours. When the container is empty, the appliance automatically changes function from water to air. At the same time, the quantity of air discharged from the rear hose will increase.
fig. 14 Open the water container compartment door, tip the container forwards and lift up to remove. Remove the cap, pull out the extendable tube and fill the container, standing it on the floor. After filling, replace the extendable tube, screw the cap on tightly and return the container to its place, making sure the word FRONT is facing out.
During "water condensation" cooling function and in particularly quiet surroundings (eg. bedroom), a slight gurgling noise may be heard. This may be regarded as perfectly normal. Warning: Do not use water containing salt, eg. seawater or water treated using softening systems that utilize kitchen salt.
9
DESCRIPTION OF PINGUINO PAC 290U CONTROLS
ON/OFF pilot light
ON/OFF button
Thermostat
A B
"Alarm" pilot light Timer Timer ON/OFF pilot light Timer ON/OFF button
C
Selecting fan speed button
SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4. 00 p. m. , turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 is lined up with the arrow pointer (the arrows indicates 4:00 p. m. [. . . ] 5) The Pinguino produces cold air but room does not maintain comfortable temperature:
-
exhaust hose blocked exhaust hose twisted or bent ventilation holes on the rear of the machine or front louvers blocked window open air exhaust hose has become disconnected thermostat set too low air filter blocked water tank empty
-
Check for obstruction of air outlet vent eliminate irregularities remove obstacles to allow proper airflow
-
-
close window re-insert exhaust hose set thermostat number clean filter refill it to higher
SERVICING
In case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance, toll-free number 1-800-322-3848 or 1 - 877-235-1052 in America or no. (905) 238-1313 for Canada.
14
FOR UNITED STATES ONLY:
LIMITED WARRANTY
We warrant each DELONGHI AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR-CONDITIONER is used in accordance with the factory directions which accompany it, and on Alternating Current (AC) circuit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PINGUINO PAC290
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.