User manual DELONGHI PINGUINO PAC400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PINGUINO PAC400. We hope that this DELONGHI PINGUINO PAC400 user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI PINGUINO PAC400.


Mode d'emploi DELONGHI PINGUINO PAC400
Download
Manual abstract: user guide DELONGHI PINGUINO PAC400

Detailed instructions for use are in the User's Guide.

[. . . ] Have your electrical system checked out by a qualified electrician. - Do not use the appliance for other than the intended use. - Do not place any strain on the power cord. - The Pinguino should not be installed where the atmosphere could contain combustible gases. [. . . ] 5) Using a 24-version wrench, unscrew the union on the coupling. At the same time, hold the end of the flexible tube tight by using a 21-version wrench. Repeat this operation for the second union using a 24- and a 19-version wrench. 7 PAC400 24-04-2003 16:29 Pagina 8 Setting up INTERNAL UNIT Install the internal unit inside the room to be airconditioned. This is usually done near a window or at least close to an outside wall. The internal unit must be placed "on the level", with the help of the castor-stops provided. No obstacles should block this unit's in-take (suction grille, rear part of the unit) or out-take (outlet grille, front part of the unit) areas. For temporary installation it is possible to hang the external unit as illustrated in the drawing. In this case, use the included straps by attaching them to the eye hooks. Before inserting the eye hooks remove the rubber plugs. EXTERNAL UNIT The external unit may be placed on a terrace or balcony, in which case the brackets need not to be used. The external unit can be attached to a wall with the accessories included as follows: 1) Attach the bracket to the wall while taking care to place it as indicated in the drawing. Use the included template located on the plastic cover in order to drill the holes. 2) To fix the support blocks to the external unit remove the two screws already inserted in the holes. Then screw the support blocks with the included M4mm screws while taking care to place them so that the hole for the screws is on the upper side. 3) Attach the external unit to the bracket by means of the M6mm screws. 2 The external unit may be installed above or at the same height as the internal unit, on the condition that the difference is no more than 5" (1. 5 m. ) The suction and air-delivery portions of external unit must not be blocked by obstacles of any nature. The distance between the back of the appliance and the wall must be six 2 1/2" (6) cm. The condensation which forms while this appliance is running (summer time operations) is disposed of by evaporation from the external unit. If the humidity is too high (in special cases), you must use the drainage coupling provided to get rid of condensation. This device must be mounted on the bottom of the external unit (see drawing) after the rubber plug has been removed. We strongly recommend that you protect the external unit from rain, snow, direct sunlight and water dripping from the roof. Gasket Castor Drainage Coupling 1 8 PAC400 24-04-2003 16:29 Pagina 9 Recommendations ELECTRICAL CONNECTIONS Check that the power supply voltage is the same as the one indicated in the rating label. Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of Pinguino. Replacement of the power cord must be carried out by qualified personnel. [. . . ] Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions which accompany it, and on Alternating Current (AC) circuit. This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations or liabilities on our part. We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PINGUINO PAC400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PINGUINO PAC400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag