User manual DELONGHI SRI M QUATTRO PLU S METROPOLI S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI SRI M QUATTRO PLU S METROPOLI S. We hope that this DELONGHI SRI M QUATTRO PLU S METROPOLI S user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI SRI M QUATTRO PLU S METROPOLI S.
Manual abstract: user guide DELONGHI SRI M QUATTRO PLU S METROPOLI S
Detailed instructions for use are in the User's Guide.
[. . . ] If the cylinder valve appears to be leaking when turned off, refit the Black Branch Cap or Orange valve Cap. - This appliance MUST NOT be used in a basement, high rise flats, bathrooms or bedrooms and in rooms having volume less than 15 m3 (30m3 in living rooms) for three burner models; 18m3 (36m3 in living rooms) for two burner models. - Be sure installation is complying to local standard. - Do not install the appliance in a room which might contain gas, oil or sulphur, or near sources of heat. [. . . ] With no flame on, remove the seal cap on the cylinder automatic valve, place the Quick-on onto the automatic valve and push down firmly and vertically. You will hear a "click" sound which means the regulator is securely latched (fig. Note: Quick-on is so designed as to prevent it from being fitted to the valve, unless the regulator handle is in the closed position; therefore, never attempt to mount or dismount it, if the handle is not in this position.
OPEN
Handle vertically flame On
Handle horizontally flame Off CLOSED
fig. 3
Operation
Once the Quick-on is correctly mounted on the valve, gas supply is possible by turning the regulator handle upwards (counterclockwise). To shut off the gas supply, reverse above procedure; an arrow engraved on the handle indicates the closing direction (fig. 3). Symbols engraved on the bonnet show how to operate the regulator handle. CAUTION: if you are unable, to open the regulator handle, this means that your Quikon is not correctly connected to the valve. Do not force the handle to open, instead start again the operations described above in 3.
GAS OFF
Replacement of a cylinder
Make sure that: - all taps on the consuming appliance are in the closed position. - the Quick-on regulator handle is in the closed position. Then, dismount the Quick-on by pressing horizontally on the handle and pulling upwards at the same time (fig. 5). Do not attempt to carry out this operation with the regulator handle in the open position.
fig. 4
2
1
GAS OFF
fig. 5
3
GENERAL SAFETY INSTRUCTIONS
Type
Category
Low output Kw 1. 50 g/h 109
Max. output Kw 4. 2 g/h 305
Med. output Kw 2. 85 g/h 207
Gas Presure
Gas combustion air quantity 8. 4 m3/h
INJECTORS 0, 82+0, 59
G30
I3B
28-30 mbar
this appliance is designed to operate with butane, at nominal pressure: 28÷30 mbar
CYLINDER VALVE
If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier. Regulators, Hoses and clips Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or damaged. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B. S. Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas cylinder. 3016 SET AT 28 MBAR (11. 2 IN W. G. ) for butane must de connected to the appliance with the above tubing, using suitable tube clips.
VENTILATION
USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is use. This ensures removal of the products combustion and allows the entry of replacement air. Adequate ventilation should considerably reduce the possibility of condensation accurring. The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided.
Heating Setting
Room Size 15 m3
Room Vent
MIN
MAX
42 m3
105 cm2
MED
28, 5 m3
MAINTENANCE
Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. [. . . ] FROM POSITION, fully depress the control knob, and turn to position (small flame). If pilot does not ignite return to starting position and repeat). Continue to fully depress the knob for a further 10 seconds to allow the thermocouple probe to heat up, then turn the knob to the required heat setting. CONTROL OF THE HEAT OUTPUT: For low output - leave control knob in position (small flame) For full output - slightly depress knob and rotate to position (big flame) For medium output - slightly depress knob and rotate to position (medium flame)(only on some models) TURNING-OFF THE HEATER The heater will only be totally "OFF" when the supply of gas from the cylinder has been turned "OFF" at the regulator valve. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI SRI M QUATTRO PLU S METROPOLI S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.