Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELTA-T RHT2. We hope that this DELTA-T RHT2 user guide will be useful to you.
Lastmanuals help download the user guide DELTA-T RHT2.
Manual abstract: user guide DELTA-T RHT2DATA SHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Delta-T Devices
Data Sheet
Relative Humidity & Air Temperature Sensors
Types RHT2nl, RHT2v & AT2
The RHT2 and AT2 sensors are designed for weather station measurements of relative humidity and air temperature. [. . . ] Thermistor output easily logged as temperature with Delta-T loggers. No sensor power requirement.
Shielded RH and Temperature Sensors
The RHT2 comprises an RH and air temperature transducer housed in the solar radiation shield. The transducer requires power and provides two output signals for the RH and air temperature.
RHT2-DS-3a. doc 23/07/03
Plug-in Replacement Modules
Routine checking at least once every year is the minimum for RH sensing elements, since the RH element may show some ageing with time. This is a common feature of all capacitative polymer type sensors. The general recommendation for the replacement interval is every two or three years, in clean atmospheric conditions. If atmospheric pollutants are present, or if the atmosphere is acidic then the replacement must be made every year. Plug-in Replacement Modules minimise the cost and delay of maintenance. They are interchangeable and can be fitted and used without any further calibration.
RHT2nl, RHT2v & AT2 Technical Specifications
Relative Humidity Sensor [RHT2nl & RHT2v models]
RH Output range Sensitivity Ageing characteristic Accuracy at 23°C Humidity linearisation Operating conditions Storage conditions Response time Load impedance Voltage supply Size and Weight Enclosure rating Output range Thermistor resistance Accuracy AT2 probe dimensions Output range Sensitivity Accuracy
specifications are subject to change without notice
0 to 100%RH 10 mV per %RH; 0 to 1 V Typical: ~-1. 5 to -2% first year; ~-1% second year; ~-0. 5% third year. [. . . ] Replacement plug-in RH & Temperature module for RHT2nl sensor Replacement plug-in RH & Temperature module for RHT2v sensor RH/Air Temp Solar radiation shield type SRS2 - suitable for RHT2nl, RHT2v and AT2 units Air Temperature Sensor type AT2 (2m cable) mounted in own solar radiation shield (± 0. 1°C, 0 to 70°C)
Delta-T Devices Ltd
128 Low Road, Burwell, Cambridge, CB5 0EJ, UK
Tel: +44 1638 742922, Fax: +44 1638 743155, E-mail: sales@delta-t. co. uk, Web: www. delta-t. co. uk
RHT2-DS-3a. doc 23/07/03 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELTA-T RHT2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELTA-T RHT2 will begin.