User manual DIGITECH RP-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DIGITECH RP-10. We hope that this DIGITECH RP-10 user guide will be useful to you.

Lastmanuals help download the user guide DIGITECH RP-10.


Mode d'emploi DIGITECH RP-10
Download
Manual abstract: user guide DIGITECH RP-10

Detailed instructions for use are in the User's Guide.

[. . . ] GROUNDING OR POLARIZATION: Precautions should be taken so that the grounding or polarization means of an appliance is not defeated. POWER CORD PROTECTION: Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance. SERVICING: To reduce the risk of fire or electric shock, the user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel. [. . . ] You can scroll through the Parameter matrix using the Parameter Select buttons. The <UP> and <DOWN> buttons allow you to scroll through the vertical Parameter LEDs, while the <LEFT> and <RIGHT> buttons allow you to scroll through the horizontal Effect LEDs. After selecting a Parameter, you can scroll through its values with the <UP> and <DOWN> Value buttons. When changing Parameter values, a decimal point will flash in the display when the value is not the stored value for the program. The Store LED will light at this time as well. If you return to the original value, the decimal point will stop flashing and the Store LED will go off. If you exit Edit mode after changing the Parameters and then return to Edit mode, the last viewed Parameter will be displayed. STORE MODE Once you have modified the Parameters and Effects, you can store them to a user Program location. When you change an Effect or Parameter in a Program, the Store LED will light, indicating that you have changed a Parameter and need to store the changes. Press the <STORE> button once and the first seven segment LED in the Display window will flash U. Select the User Bank and Program location you want to store your changes to, and press the <STORE> button again to save the changes. 8 User Guide RP-7 Valve Section - 3 Basic Operations BYPASS MODE Allows you to bypass the RP-7 Valve's Effects. Enter this mode by pressing footswitches <3 & 4> simultaneously. · Press foot switches <2> and <3> to enter Learn-a-lick mode. · Cue up to the passage you want to record and hit pause on the CD or tape player. · Release the pause button and press the <4> foot switch when you are ready to begin recording the passage. The display will read: rEC and recording will begin. When recording is completed, the phrase is then set into an auto-loop playback mode. Stop or press pause on the CD or Tape player. · Pressing the <Tempo Dn> foot switch will slow the playback down to 1/2 speed in 1/8th speed intervals. · Pressing the <Tempo Up> foot switch will increase the playback speed to normal speed at 1/8th speed intervals. · Pressing the <Rewind> foot switch steps back through the loop at 1 second intervals. · Pressing the <F Forward> foot switch steps forward through the loop at 1 second intervals. · The Expression pedal will control output level of auto loop. [. . . ] There are ten available type settings: CLub=Club Garg=Garage pLat=Plate HALL=Hall SStg=Sound Stage Chur=Church bAth=Bathroom ArEn=Arena Stud=Studio SPrg=Spring Controls the amount of reverb signal to be mixed in with the dry signal. The amount of time it takes for the Reverb to fade to inaudibility. Ranges from 1 to 10. Level Decay Time User Guide 19 Section - 4 Effects and Parameters RP-7 Valve Speaker Cabinet Emulator Parameters On/Bypass Type Displayed Values On-Byp 1. . . 10 The RP-7 Valve's programmable Speaker Cabinet circuitry allows you to use it in both recording and live situations without lugging heavy amps and/or cabinets around. Just connect the RP-7 Valve's outputs to a mixing console and kick in the Speaker Cabinet. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DIGITECH RP-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DIGITECH RP-10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag