User manual DOMETIC BASEMENT INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC BASEMENT. We hope that this DOMETIC BASEMENT user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC BASEMENT.


Mode d'emploi DOMETIC BASEMENT
Download

You may also download the following manuals related to this product:

   DOMETIC BASEMENT PARTS LIST (173 ko)

Manual abstract: user guide DOMETIC BASEMENTINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS RECORD THIS INFORMATION FOR FUTURE REFERENCE BEFORE INSTALLING THE UNIT: Model Number Serial Number Date Purchased Place of Purchase USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center Assistance Call: 800-544-4881 SELF-CONTAINED AIR CONDITIONER & HEAT PUMP FOR RECREATIONAL VEHICLES ROTARY COMPRESSOR SYSTEM MODELS Air Conditioners 39626. 501 & 39626. 506 Heat Pumps 39726. 501 & 39726. 506 !AVERTISSEMENT Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. L'installation de cet appareil doit être effectuée par un réparateur qualifié. Toute modification de cet appareil peut être extrêmement dangereuse et entraîner des blessures ou dommages matériels. THIS UNIT IS DESIGNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT. ! [. . . ] These guidelines give minimum requirements for duct sizing, duct arrangement and register location so that you receive maximum performance from the system. These instructions DO NOT cover or warrant the final installation of the duct work that carries conditioned air within the ceiling cavity. The installer is responsible for the integrity of the insulated duct within the structure to insure that moisture laden air does not condense on duct surfaces. If proper practices are not adhered to, condensation will collect during high ambient conditions. Damage caused by condensation will not be covered by Dometic Corporation warranties. 9 INSTALLATION INSTRUCTIONS 2. 6 WIRING DIAGRAM 39726. 501 & 39726. 506 RED WHT G-Y BLK WHT G-Y BLK DIP SWITCHES ON P1 P2 AMB. SENSOR F1 3 AMP FUSE RED BLK BLU BLU YEL YEL BLK ELEC. COIL ORN P6 12 3 4 5 67 8 CIRCUIT BOARD T4 NC ORN K6 COM T2 T3 RED NO NC HERM C FAN RUN CAP VIO BLK VIO BLK WHT WHT WHT VIO VIO BLK BLK REV. VALVE ASM COMP STARTER START CAP T1 RED WHT RED BLK WHT WHT WHT C BRN BRN RED BLK S OL EVAP. BLOWER MOTOR COMPRESSOR R 115 VAC 60 Hz 1O USE COPPER CONDUCTORS ONLY CIR. #1 K1 COM NO FREEZE CONTROL P3 P4 P5 FIELD WIRING MUST COMPLY WITH THE NATIONAL ELECTRIC CODE BLK WHT REV. VALVE ASM PASSED DIELECTRIC WHT ORN ELEC. BOX BLKHD WHT BRN MOTOR CAP BRN ORN GRY GRY C RUN CAP BRN GRY WHT RED START CAP COMP STARTER BLK WHT COND. BLOWER MOTOR COMPRESSOR BRN BRN C S R 115 VAC 60 Hz 1O USE COPPER CONDUCTORS ONLY ORN G-Y GRY CIR. #2 HERM OL BLK G-Y WHT FIELD WIRING FACTORY WIRING = WIRE NUT 3108345. 095 2. 7 SPECIFICATIONS - HEAT PUMP System Model Nominal BTU Capacity Volts/Phase/Hertz (each circuit) Run Amps Comp LRA Compressor Total Blwr/Fan Motor Run Amps Total Blwr/Fan Motor LRA Amps Duct Static - Min. Water Column) Generator Size Per/Unit - Min. *** Wire Size (Up to 24 ft. )** (Suggested) Circuit Protection Time Delay Fuse or HACR Circuit Breaker Control Voltage Refrigerant System Refrigerant Charge Size (In Inches) Installed Weight * (Circuit 1 = 46. 5) Width 46 Height 18 205 Pounds (Circuit 1 =10. 0) (Circuit 1 = 59. 0) 39726. 501 & 39726. 506* 26, 000 115 AC / 1 / 60 (Circuit 2 = 9. 8) (Circuit 2 = 59. 0) 8. 5 (Circuit 1) 18. 0 (Circuit 1) 0. 40 1. 20 7. 5K (Circuit 1) No. 10 AWG Copper Conductors) (Circuit 2) No. 12 AWG Copper Conductors) (Circuit 1) 25Amp (Circuit 2) 15Amp 12V DC R-22 (Circuit 2 = 38. 5) Depth 22 Models ending with . 506 suffix and manufactured with "SIDE AIR DISCHARGE". ** For wire lengths over 24 ft. consult the National Electric Code for proper sizing. *** The Manufacturer gives only general guidelines for generator requirements. These generator requirements come from experiences consumers have with our equipment in field applications. When sizing the generator, the total electrical power must be taken into consideration. Keep in mind that generators lose power because of altitude increases above sea level , high outdoor temperatures and lack of maintenance. 8 WIRING DIAGRAM 39626. 501 & 39626. 506 EVAP BLOWER . RED WHT G-Y BLK DIP SWITCHES MOTOR COMPRESSOR R WHT G-Y BLK CIRCUIT COMP STARTER START CAP K1 COM BOARD WHT WHT RED BLK RED WHT C OL S BRN BRN RED CIR. #1 115 VAC 60 Hz 1 PHASE USE COPPER CONDUCTORS ONLY P2 P3 FIELD WIRING MUST COMPLY WITH THE NATIONAL ELECTRIC CODE AMB. [. . . ] The location of the Comfort Control CenterTM may create a condition where the normal differential will not maintain the temperature at your comfort level. If this occurs, the Differential can be shortened by placing the Differential dip switch to the "ON" position. The "GEN START" dip switch - leave in the "OFF" position. 3. 5. 2 SYSTEM RESET On new installation the COMFORT CONTROL CENTER TM, and/or any changes made to the dip switches requires the electronic control kit to be reset. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC BASEMENT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC BASEMENT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag