User manual DOMETIC BRISK AIR HP INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC BRISK AIR HP. We hope that this DOMETIC BRISK AIR HP user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC BRISK AIR HP.


Mode d'emploi DOMETIC BRISK AIR HP
Download

You may also download the following manuals related to this product:

   DOMETIC BRISK AIR HP PARTS LIST (207 ko)

Manual abstract: user guide DOMETIC BRISK AIR HPINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46, Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center Assistance Call: 800-544-4881 520 Series DUO-THERM HP 530 Series DUO-THERM HP HEAT PUMP 579 Series BRISk AIR 590 Series BRISk AIR 591 Series HEAT PUMP 595 Series QUICk COOL 600 Series PENgUIN 630 Series PENgUIN Roof Top Air Conditioners & Heat Pumps Used With Part No. 3109226. 005 & 3109407. 001 Comfort Control Center Electronic Control kit Ducted Installation Using 3109228. 001 (White) Comfort Control CenterTM OR 3109228. 019 (Black) Comfort Control CenterTM THIS UNIT IS DESIgNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY DOMETIC CORPORTION This manual must be read and understood before installation, adjustment, service, or maintenance is performed. This unit must be installed by a qualified service technician. Modification of this product can be extremely hazardous and could result in personal injury or property damage. Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. [. . . ] 6. 10 Black Red green Yellow Pin 1 CCC Ducted Installation Instructions FIg. Remove the air conditioner from the carton and discard carton. The unit mounting bolts and literature are in a separate plastic bag. Be sure to place this information in the RV. PLACINg THE AIR CONDITIONER ON THE ROOF This unit weighs approximately 100 pounds. To prevent back injury, use a mechanical hoist to place air conditioner on roof. C. Lift and place the unit over the prepared opening using the gasket on unit as a guide. The roof gasket on the bottom of the base pan goes toward the front of the RV. Sliding the unit on the roof will damage the roof gasket. This may damage the neoprene gasket attached to the bottom and create a leaky installation. D. Install the Air Distribution Ducts in the RV Roof Cavity. System requirements listed in Section 4 on page 6 of this Manual. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/8") opening previously cut. 2, 3 & 4. 11 CCC Ducted Installation Instructions A. 520, 530, 579, 590, 591 AND 595 SERIES 8. Insert the Freeze Control Sensor approximately 1" into the fins of the evaporator coil as shown in FIG. Bend fins over sensor to secure in place. Plug the freeze control sensor cord into the mating connector on the Electronic Control kit. These connectors are polarized and will easily snap together. 9 520, 530, 579, 590, 591 & 595 FREEzE CONTROL 600 & 630 FREEzE CONTROL FIg. 600 & 630 SERIES 1. Insert the Freeze Control Sensor approximately 1" into the evaporator coil fins located at the right side of the evaporator, as shown in FIG. Bend fins over sensor to secure in place. [. . . ] can damage the switch causing loss of connection. Use only a small flat blade screw driver ( wider than the dip switch slot) to move the dip switch. Zone selection - when two or more units are installed and controlled by one Comfort Control CenterTM, the second unit becomes Zone 2, the third unit Zone 3, and the fourth unit Zone 4. The appropriate zone dip switch must be set in each electronic control box for the Zone 2, 3 and 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC BRISK AIR HP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC BRISK AIR HP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag