User manual DOMETIC L-2448B INSTALLATION FOR REMOTE ICE-MAKING SYSTEMS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC L-2448B. We hope that this DOMETIC L-2448B user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC L-2448B.


Mode d'emploi DOMETIC L-2448B
Download
Manual abstract: user guide DOMETIC L-2448BINSTALLATION FOR REMOTE ICE-MAKING SYSTEMS

Detailed instructions for use are in the User's Guide.

[. . . ] Eskimo Ice INSTALLATION MANUAL FOR REMOTE ICE-MAKING SYSTEMS For model: · EIR600D Control Panel Condensing Unit Auger Unit EIR600D Components Dometic Marine Division Rev. 20100308 L-2448B English COPYRIGHT © 2008-2010 Dometic Marine Division. No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Marine. Every precaution has been taken in the preparation of this manual to insure its accuracy. [. . . ] A self-draining system, however, allows air in the piping to rise naturally through the pump and be expelled. It also makes winterizing the system much easier. Figure 3, page 8 shows a properly plumbed system and some common mistakes. L-2448B ENGLISH 7 INSTALLATION PROCEDURES Eskimo Ice Installation Manual - Remote System Figure 3: Seawater Piping Recommendations Thru-Hull Inlet Fitting A separate thru-hull fitting must be installed for each seawater pump. Do not attempt to draw water from the thru-hull fitting of an engine, generator, or other device. Install a scoop-type thru-hull fitting: 1. Drill a properly sized hole for the thru-hull fitting as far below the water line and as close to the keel as possible. Make sure the scoop of the thru-hull fitting faces the bow. Bed the scoop with marine sealant designed for underwater use, and tighten the nut onto the thru-hull to secure it. Seacock The seacock must be accessible and easy to close in case of emergency or to clean the strainer. · · · · · · Install a full-flow seacock directly onto the thru-hull fitting. Use Teflon tape or equivalent to seal the threads. Only use reinforced marine-grade hose or other suitable piping (PVC, CPVC, cupronickel, or stainless steel). Use only plastic, bronze, or stainless steel fittings (do not use brass). Make sure enough hose is used to allow for future removal of components. Use the correct size hose, fittings, and components: 5/8" seawater hose, 3/4" inlet. Note that the pump inlet piping (including thru-hull and strainer) may need to be larger than the outlet pipe size. Do not use pump connections to determine hose size. The "pump inlet" recommended pipe size includes all fittings and hose up to the pump connection (thru-hull, seacock, strainer, hose, manifold). The "pump discharge" recommended pipe size includes all fittings and hose from the pump discharge up to the overboard discharge, and should be a minimum of 5/8". L-2448B ENGLISH Seawater Piping · 8 Eskimo Ice Installation Manual - Remote System INSTALLATION PROCEDURES Strainer A seawater strainer must be installed between the seacock and the pump, and should be situated to provide easy access for cleaning. The strainer must be located vertically above the seacock and below the pump so any air that gets into the strainer can get out. Mount the strainer to a bulkhead so it is properly supported before connecting hoses. Make sure the water flow through the strainer is in the correct direction. [. . . ] Set per instructions in "Setting the CPV" on page 14. If under warranty, call for authorization before adjusting CPV, otherwise warranty will be voided. Low-pressure fault. (LPF) L-2448B ENGLISH 15 TECHNICAL ASSISTANCE Eskimo Ice Installation Manual - Remote System PROBLEM Ice-clog fault. (SPT) POSSIBLE REASONS & SOLUTIONS 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC L-2448B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC L-2448B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag