User manual DOMETIC L-2514

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC L-2514. We hope that this DOMETIC L-2514 user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC L-2514.


Mode d'emploi DOMETIC L-2514
Download
Manual abstract: user guide DOMETIC L-2514

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH Ice Flow Water Flow High Pressure Low Pressure Comp Auger Ice Bin Full Power On/Off Function Dometic eskimo ice crusheD ice systems oPerAtioN mANuAL For Self-Contained & Remote Systems Using Digital Controls (For b-16 to c-18 Software) Dometic Corporation, Marine Division Rev. 20100730 L­2514 COPYRIGHT © 2007, 2008 Dometic Corporation, All Rights Reserved. No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Corporation. Every precaution has been taken in the preparation of this manual to insure its accuracy. [. . . ] Default setting is off and can be set from 75 to 100 or 175 to 200. 5 eskimo ice systems t-3: cAN iD: Used to set CAN bus ID. t-5: reset Programmable Parameters: Resets all programmable parameters to factory defaults. Set this setting to 1 and unit will reset all values. Setting will change back to 0 on exit of the programming mode or by pressing the On/Off button to scroll through parameters. Note: Changes to technical parameters not listed above should be performed by an authorized service dealer. Please contact Dometic at 800-542-2477 for a dealer near you. Programmable Parameter table No P-1 t-1 t-2 t-3 t-4 t-5 Description High Pressure Restart Delay Low AC Line Voltage CAN ID Group ID Reset Programmable Parameters Default 0 off n/a 5 0 Range 0 - 30 minutes 75-100 or 175-200 1-254 1-254 0 = No, 1 = Yes Figure 1. Programmable Parameter Table eNGLish 6 eskimo ice systems typical operation cycle table ACTION Initial Start Up Via Breaker Pump ON Auger ON Compressor ON Ice Production BIN FULL Auger Clears Machine Shuts Down Ice removed from bin Pump ON Auger ON Compressor ON Ice Production FAULT Trip - HPF, LPF, etc. Clearing Auger Machine Shuts Down Fault Trip Corrected Pump ON Auger ON Compressor ON Ice Production Will continue until sensor reads bin full for 30 sec. , fault trip or unit manually shut down. 30 15 60 30 Will continue until sensor reads bin full for 30 sec. , fault trip or unit manually shut down. 30 15 Sensor reads bin not full, calls for ice production. 30 Will continue until sensor reads bin full for 30 sec. , fault trip or unit manually shut down. Delay before Next Step (in seconds) and/or description of action 60 30 15 Assumed display is in ON position. If not, turn unit on via display. Note: Above is an example of a typical operation cycle based on default values, cycle will change depending on end user parameter changes. Figure 2. Typical Operation Cycle eNGLish 7 eskimo ice systems Figure 3. Wiring Diagram for digital control eNGLish 8 eskimo ice systems Figure 4. Location of Ice Bin Sensor Display Cut Out Dimensions 3. 1875 3. 1875 Figure 5. This warranty gives you, the purchaser, specific legal rights, and you may also have other rights which vary from state to state. You also have implied warranty rights, including an implied warranty of merchantability, which means that your product must be fit for the ordinary purposes for which such goods are used. The duration of any implied warranty rights is limited to the duration of the express warranty as found in Section III. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Section II What does this Limited Warranty not cover?Failures resulting from improper installation or use contrary to instructions. Failures resulting from abuse, misuse, accident, fire, or submergence. [. . . ] Note: Any model or replacement part that has been installed due to a warranty failure will carry only the remainder of the original warranty. All warranties begin when the customer takes possession of the equipment. The warranty is extended to all owners of the equipment commencing the date the original owner takes possession of it. Proof of original purchase may be required. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC L-2514

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC L-2514 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag