User manual DOMETIC NDR1292-S INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC NDR1292-S. We hope that this DOMETIC NDR1292-S user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC NDR1292-S.


Mode d'emploi DOMETIC NDR1292-S
Download
Manual abstract: user guide DOMETIC NDR1292-SINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Ill Dometic NDR 1292-S INSTALLATION AND OPERATING INSTRUCTIONS REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION NDR1292-S FOR YOUR SAFETY If you smell gas: 1. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier. NEWDIMENSIONS Contents: Installation Operating Instructions Maintenance & Sewice Page 4 0 12 AVIS Cet appareil doit 6tre repark seulement par un reparateur autorise. [. . . ] The GAS mode indicator lamp (C)will illuminate. Within 45 seconds the burner should be ignited and operating normally. On the initial refrigerator start-up, it may take longer than 45 seconds to allow air to be purged from the gas line. If the gas does not ignite within 45 seconds the CHECK indicator lamp (D) will illuminate and the GAS mode indicator lamp (C)will go off To reset when the CHECK indicator lamp (D) is illuminated, press the main power ON/OFF button (1) to the OFF and then ON position. NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries. Press the TEMPERATURE SELECTOR button (3) until the lamp at the desired position is illuminated. 9 E F G DESCRIPTION OF OPERATING MODES AESlAUTO MODE When operating in the AES/AUTO mode, the AES/AUTO mode indicator lamp (6) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. Either the AC indicator lamp (A) or the GAS indicator lamp (C) will illuminate depending on the energy source selected by the control system. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS. As soon as AC becomes available again the control will switch back to AC regardless of the status of GAS operation. LIMP MODE OF OPERATION This control system contains a feature where it will continue to operate the cooling system in the event of a failure of a major operating component. Two different modes of operation can occur in this category If for some reason the display module becomes non functional, the control system will revert to full automatic operation selecting the best energy source available with AC, GAS priority The temperature of the refrigerator will be maintained at the MID position within normal temperature tolerances. The power module will continually attempt to reestablish operation of the display module. The second limp mode of operation will execute when a failure of the temperature sensing device or associated electronic circuitry occurs. If this should occur, the control system will operate on the energy source selected via the control panel. The cooling unit will run continuously on the selected energy source. The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed and the system is reset. GAS MODE When operating in the GAS mode theAES/AUTO mode indicator lamp (6) will be off and the GAS mode indicator lamp (C)will be illuminated. This mode provides LP gas operation only. The control system will activate the ignition system and will attempt to light the burner for a period of approximately45 seconds. If unsuccessful, the CHECK indicator lamp (D) will illuminate and the GAS mode indicator lamp(C) will turn off. To restart GAS operation, press the main power ONI OFF button (1) to the OFF and then ON position. The control system will attempt a new 45 seconds ignition S?q"e"CCT If the refrigerator has not been used for a long time or the LP tanks have just been refilled. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. [. . . ] Check to make sure slots are centered under the flue tube and the thermocouple is positioned properly (tip of thermocouple extends over ho slots of burner). Be sure to reconnect the wire to high voltage electrode. Check the electrode for proper location and gap. Turn on manual gas shutoff valve and check all fittings for leaks. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC NDR1292-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC NDR1292-S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag