User manual DOMETIC RM2351 INSTALLATION INSTRUCTIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOMETIC RM2351. We hope that this DOMETIC RM2351 user guide will be useful to you.

Lastmanuals help download the user guide DOMETIC RM2351.


Mode d'emploi DOMETIC RM2351
Download

You may also download the following manuals related to this product:

   DOMETIC RM2351 PARTS LIST (152 ko)
   DOMETIC RM2351 INSTALLATION (3128 ko)

Manual abstract: user guide DOMETIC RM2351INSTALLATION INSTRUCTIONS

Detailed instructions for use are in the User's Guide.

[. . . ] ® INSTALLATION AND OPERATING INSTRUCTIONS REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION RM2351 Contents: Installation Operating Instructions Maintenance & Service Page 4 8 12 FOR YOUR SAFETY If you smell gas: 1. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Pour votre sécurité Si vous sentez une odeur de gaz: 1. [. . . ] NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries. In GAS mode operation, the temperature is controlled by a factory preset temperature setting. AUTO MODE 1. Press the AUTO/GAS mode selector button (2) to the DOWN position. The AUTO mode indicator lamp (A) will illuminate. If 120 volts AC is available, the control system will select AC operation. If 120 volts AC is not available, the control system will automatically switch to GAS operation. Within 45 seconds the burner should be ignited and operating normally. If the CHECK indicator lamp (B) illuminates, the control has failed to ignite the burner on GAS. To reset when the CHECK indicator lamp (B) is illuminated, press the main power ON/OFF button (1) to the OFF then ON position. On the initial refrigerator start-up on gas (120 volts AC is not available), it may take longer than 45 seconds to allow air to be purged from the gas line. If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open. If the problem is still not corrected, contact a service center for assistance. NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries. In AUTO mode operation, the temperature is controlled by a factory preset temperature setting. TO SHUT OFF THE REFRIGERATOR The refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button to the UP (OFF) position. This shuts off all DC power to the control system. 9 Refrigerator control panel A B ON AUTO CHECK 1 OFF 2 GAS AUTOMATIC REFRIGERATOR TEMPERATURE CONTROL DESCRIPTION OF OPERATING MODES AUTO MODE When operating in the AUTO mode, the AUTO mode indicator lamp (A) will illuminate. The control system will automatically select between AC and GAS operation with AC having priority over GAS. If the control system is operating with AC energy and it then becomes unavailable, the system will automatically switch to GAS . As soon as AC becomes available again the control will switch back to AC operation. Gas operation (120 volts AC is not available). The control system will activate the ignition system and will make three attempt to light the burner for a period of approximately 45 seconds with two minutes interval. [. . . ] Disconnect the wall plug, and the 12 volt wires. Control system AC heater 3 Amp 5 Amp !WARNING DO NOT use a wire or pin when cleaning the burner jet as damage can occur to the precision opening. This can cause damage to the refrigerator or create a fire hazard. 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOMETIC RM2351

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOMETIC RM2351 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag