Detailed instructions for use are in the User's Guide.
[. . . ] 2722
· · · · · · · · · · · ·
S P E C I F I C AT I O N S H E E T
Leading the way: Next-generation connectivity and flexibility.
Built in Redundancy · RAID 0, 1, 3, 5, 6, 10, 50 · Redundant, hot swap components · AssuredSnapTM - Optional snapshot capability · AssuredCopyTM - Additional data protection with full volume copies · Built-in schedule capability Scalability and Performance · Dual or single RAID controller or JBOD · Data rates of 4Gb/sec. [. . . ] With support for a total of 96 attached drives managed by the Dot Hill R/Evolutionary RAID architecture, the 2722 adapts to a broad range of business and mission-critical applications including databases, business analysis, video streaming and email.
· · · · · · · · ·
Revolutionary connectivity, availability, quality and value
The 2722 uses revolutionary SimulCacheTM technology that instantly and simultaneously mirrors cache between RAID controllers, leading to significant performance improvements over traditional implementations. The use of RAID cache batteries has been completely eliminated with the introduction of super capacitors, providing infinite cache backup during a power loss while being environmentally friendly. AssuredSnapTM provides the 2722 with built-in volume snapshot capability allowing point-in-time copies that can be used to maximize business continuity. AssuredCopyTM creates a full volume copy (vs. a logical volume copy with AssuredSnap) providing additional protection against vdisk failure and eliminating application I/O contention when accessing the same data blocks.
2722 FC
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ª · · · · · · · · · · · · · · · · · · · · · · ··
Storage made easy
The 2722 is easy to configure and manage with improved RAIDar 2. 0, the intuitive Web Based Interface (WBI) which provides storage setup and monitoring without the need for host based software.
spec
®
2722 Specifications
GENERAL
································································
DECLARED ACOUSTIC NOISE LEVELS . . . . . . . . . . . . . . . . . . . . . . . .
Sound Power Sound Pressure <6. 75B Sound Power <55dBA Sound Pressure
Product Family Product Type Chassis Configuration Disk Architecture Max Drives per Chassis Total Disks Supported Mounting Options Max Number of Chassis Max Capacity per Chassis Data Management Services (DMS)
2002 Series RAID, JBOD 2U 3Gb SAS 24 drives 96 19" Rack, Rack tray 7 (1 RAID and 6 JBOD) 7. 2TB AssuredSnapTM, AssuredCopyTM
SHOCK AND VIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-Operational 5. 0G, 10ms, half sine 15G 11ms, half sine 0. 21Grms Random 5Hz to 500Hz flat spectrum/feed forward 0. 5G 1 octave/minute 5Hz to 500Hz to 5 Hz sine sweep 0. 5Grms Random 20Hz to-1000Hz flat spectrum
···································
PROTOCOLS AND STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IP (RFC, 894, 1092) SCSI-2 and SCSI-3
HIGH-AVAILABILITY FEATURES HOSTS
······························································
Supported Hosts Interface Type External Ports
Up to 4 direct connected hosts, 2 or 4Gb Fibre Channel FCP 2 Single or 4 Dual Controller 96 SAS 36GB 15K RPM SAS 72GB 15K RPM SAS 146GB 10K RPM SAS 300GB 10K RPM SATA 32GB SSD SATA 64GB SSD SATA 80GB SSD SATA 160GB SSD Non-RAID, 0, 1, 3, 5, 6, 10 and 50 Hardware 1GB per controller Battery-free protection with super capacitors 32 256 256 Yes - SimulCacheTM Yes Yes - Non-volatile
DRIVES
···································································
Max Number of Drives Drive Options
Redundant Hot-Swap Controllers Redundant Hot-Swap Disk Redundant Hot-Swap Fans Redundant Hot-Swap Power Dual Power Cords Hot Standby Spare Automatic Failover Multi-Path Support Snapshot with AssuredSnapTM Volume Copy with AssuredCopyTM
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
REGULATORY
Safety
···························································
UL 60950-1:2001 (USA) CAN/CSA-C22. 2 No. 60950-1-03 (Canada) EN 60950-1 :2001 (EU) IEC 60950-1 :2001 (International)
RAID
Levels Supported RAID Type Cache Memory Cache Backup Virtual disks per System Volumes per virtual disk Volumes per System Mirrored Cache Super Capacitor Cache Backup Cache Backup to Flash
······································································ 6
Electromagnetic Compatibility Emissions
Harmonics Flicker Immunity
MANAGEMENT
·························································
Interface Types Protocols Supported Management Consoles Management Software
Mini DB9 RS232, 10/100 Ethernet SNMP, SSL, SSH, SMTP, SMI-S Provider, HTTP(S) WEB GUI, CLI RAIDar 2. 0
···························
CFR 47 Part 15 Subpart B Class A (USA) IECS-003: 2004 Class A (Canada) AS/NZS CISPR 22: 2006 Class A (Australia/ New Zealand) VCCI: 2008-4 Class A EN 55022: 2006 Class A (European Union) EN 61000-3-2: 2006 EN 61000-3-3: 1995 (Amended by A1: 2001 and A2: 2005) EN 55024: 1998 (Amended by A1: 2001and A2: 2003)Electromagnetic Compatibility RoHS-6 Compliance , China RoHS, WEEE Australia/New Zealand, Canada, European Union (EU), Germany (GS Mark), Japan, United States 90 days 3 years SNMP, CLI, RAIDar 2. 0, SMTP, SMI-S Provider Yes Yes Yes Yes for primary volumes and snapshot volumes 3. 5 Inches / 8. 9cm 21. 3 Inches / 54. 0 cm 17. 6 Inches / 44. 7cm 44 lbs / 20kg 58 bs / 26. 4kg
RoHS and WEEE Country Approvals
POWER REQUIREMENTS - AC INPUT
Input Power Requirements Max Input Power Heat Dissipation
100-240VAC 50/60Hz 4. 51. 9A 436W max maximum continuous 1488 BTUs/hour
···························
SUPPORT
POWER REQUIREMENTS - DC INPUT
Voltage Max Input Power Heat Dissipation
-34 to -72VDC, -48/-60V nominal 436W maximum continuous 1488 BTU/hour
Software Warranty Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion
······························································· ·
TEMPERATURE AND HUMIDITY RANGES . . . . . . . . . . . . . . . . . . .
Operating Temperature Shipping Temperature 41°F to 104°F (5°C to 40°C) -40°F to 158°F (-40°C to 70°C) Note: Derate 2°C for every km, up to 3000 meters 10% to 90% RH @ 104°F (40°C), non-condensing Up to 93% RH @ 104°F (40°C) non-condensing
PHYSICAL
·······························································
Operating Humidity Non-Operating Humidity
Height Depth (excluding cables) Width Chassis Weight Chassis (w/148GB drives) Weight
Specifications are subject to change at any time.
© 2009, Dot Hill Systems Corp. , All rights reserved. Dot Hill, the Dot Hill logo, the R/Evolution logo, R/Evolution, AssuredSnap, AssuredCopy, EcoStor and SimulCache are all trademarks of Dot Hill Systems Corp. [. . . ] No part of this document may be copied or reproduced without written permission of Dot Hill Systems Corp. [. . . ]