User manual DOT HILL 2730 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DOT HILL 2730. We hope that this DOT HILL 2730 user guide will be useful to you.

Lastmanuals help download the user guide DOT HILL 2730.


Mode d'emploi DOT HILL 2730
Download
Manual abstract: user guide DOT HILL 2730DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 2730 S P E C I F I C AT I O N S H E E T Leading the way: next-generation performance and flexibility. Built in Redundancy · RAID 0, 1, 3, 5, 6, 10, 50 · Redundant, hot swap components · AssuredSnapTM - Built-in snapshot capability · AssuredCopyTM - Additional data protection with full volume copies · Built-in schedule capability Scalability and Performance · Dual or single RAID controller or JBOD · Data rates up to 4Gb/sec (Fibre Channel) · 1. 7TB base capacity that scales to 112TB (utilizing 2TB SATA drives) · OS Support - Windows, Linux, SuSE, Solaris · Modular design protects your investment · Enterprise-class features and functionality without the enterprise price Environmentally Responsible / Lower TCO · EcoStorTM - Economically and environmentally sound technologies - SimulCacheTM - Low latency cache mirroring - Battery-free cache backup - DC power option - 1 terabyte energy-saving drives · RoHS-5 and WEEE compliant · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · The 2730 features a 12-drive array housed in a 2 rack-unit (RU) enclosure providing 4Gb FC interfaces to internal SAS or SATA-II disk drives. [. . . ] AssuredSnapTM provides the 2730 with built-in volume snapshot capability allowing point-in-time copies that can be used to maximize business continuity. AssuredCopyTM creates a full volume copy (vs. a logical volume copy with AssuredSnap) providing additional protection against vdisk failure and eliminating application I/O contention when accessing the same data blocks. 2730 FC Storage made easy Easily configure and manage the 2730 with RAIDar, the intuitive Web Based Interface (WBI) which provides storage setup and monitoring without the need for host based software. spec 2730 Specifications GENERAL ································································ Product Family Product Type Chassis Configuration Disk Architecture Max Drives per Chassis Total Capacity Total Disks Mounting Options Max Number of Chassis Max Capacity per Chassis Data Management Services (DMS) 2000 Series RAID, JBOD 2U 3Gb SAS/3Gb SATA-II 12 drives 1. 7TB/56TB (with expansion trays) 56 19" Rack, Telco Rack, Rack tray 5 (1 RAID and 4 JBOD) 24TB (2TB SATA-II drives) AssuredSnap, AssuredCopy SHOCK AND VIBRATION. . . . . . . . . . . . . . . . . . . Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-Operational ························· 5. 0G, 10ms, half sine 15G 11ms, half sine 0. 21Grms Random 5Hz to 500Hz flat spectrum/feed forward 0. 5G 1 octave/minute 5Hz to 500Hz to 5 Hz sine sweep 0. 5Grms Random 20Hz to-1000Hz flat spectrum ··································· HIGH-AVAILABILITY FEATURES Redundant Hot-Swap Controllers Redundant Hot-Swap Disk Redundant Hot-Swap Fans Redundant Hot-Swap Power Dual Power Cords Hot Standby Spare Automatic Failover Multi-Path Support Snapshot w/AssuredSnap Volume Copy w/AssuredCopy Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes MODELS ································································· Model Numbers 2730 - 4Gb FC Interface 2730T - High performance 4Gb FC Interface Up to 4 direct connected hosts, 2 or 4Gb Fibre Channel FCP 2/4 Dual Controller HOSTS dire································································ ··· Supported Hosts Interface Type External Ports DRIVES ··································································· Max Number of Drives Drive Options 56 3GB SAS 146GB 15K RPM 3GB SAS 300GB 15K RPM 3Gb SAS 450GB 15K RPM 3GB SATA-II 500GB 7200 RPM 3GB SATA-II 750GB 7200 RPM 3GB SATA-II 1TB 7200 RPM 3Gb SATA-II 1TB 5400 RPM 3Gb SATA-II 2TB 5400 RPM Non-RAID, 0. 1, 3, 5, 6, 10, and 50 Hardware Up to 1GB per controller Battery-free protection with super capacitors 32 128 256 Yes - SimulCacheTM Yes Yes - Non-volatile Mini DB9 RS232, 10/100 Ethernet SNMP, SSL, SSH, SMTP WEB GUI, CLI RAIDar REGULATORY Safety ··························································· UL 60950-1:2003 (USA) CAN/CSA-C22. 2 No. 60950-1-03 (Canada) EN 60950-1 :2001 + A11 (European Union) IEC 60950-1 :2001 (International) CFR 47 Part 15 Subpart B (U. S. A. , Class A) ICES-003 Issue 4 (Canada, Class A) EN 55022 :98 +A1 +A2 (European Union, Class A) EN61000-3-2:2000+A1, +A2, +A14 (Harmonics) EN 61000-3-3 :2001 (Flicker) EN 55024 :1998 +A1 (European Union, Immunity) CISPR 22 :2005 (International, Class A) CISPR 24 :97 (International, Immunity) RoHS-5 Compliance , China RoHS, WEEE Australia/New Zealand, Canada, China (PRC), European Union, Germany (GS Mark), Japan, South Korea, Taiwan, United States Electromagnetic Compatibility RAID ······································································ Levels Supported RAID Type Cache Memory Cache Backup Virtual disks per System Volumes per virtual disk Volumes per System Mirrored Cache Super Capacitor Cache Backup Flash Cache Backup RoHS and WEEE Country Approvals MANAGEMENT ························································· Interface Types Protocols Supported Management Consoles Management Software SUPPORT POWER REQUIREMENTS - AC Input Power Requirements Max Input Power Heat Dissipation ···································· ······························································· · 100­240VAC, 50/60 Hz, 4. 5-1. 9A 475W maximum continuous 1622 BTU/hour ···································· POWER REQUIREMENTS - DC Voltage Max Input Power Heat Dissipation -39 to -72VDC, -48/-60V nominal 500W maximum continuous 1706 BTU/hour Software Warranty Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion 90 days 3 Years SNMP, CLI, RAIDar, SMTP Yes Yes Yes Yes for primary volumes and snapshot volumes PHYSICAL TEMPERATURE AND HUMIDITY RANGES . . . . . . . . . . . . . . . . . . . . . Operating Temperature Shipping Temperature 41°F to 104°F (5°C to 40°C) -40°F to 158°F (-40°C to 70°C) Note: Derate 2°C for every km, up to 3000 meters 10% to 90% RH @ 104°F (40°C), non-condensing Up to 93% RH @ 104°F (40°C) non-condensing <6. 03B Sound Power <55dBA Sound Pressure ······························································· Height Depth (excluding cables) Width Chassis Weight Chassis (w/250GB drives) Weight 3. 5 Inches / 8. 9cm 23. 7 Inches / 60. 2cm 17. 6 Inches / 44. 7cm 44lbs. / 29. 48kg Operating Humidity Non-Operating Humidity DECLARED ACOUSTIC NOISE LEVELS . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound Power Sound Pressure © 2008, Dot Hill Systems Corp. , All rights reserved. Dot Hill, the Dot Hill logo, the R/Evolution logo, R/Evolution, AssuredSnap, AssuredCopy, EcoStor, SimulCache and SANnet are all trademarks of Dot Hill Systems Corp. This document is for informational purposes only, and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Dot Hill. [. . . ] No part of this document may be copied or reproduced without written permission of Dot Hill Systems Corp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOT HILL 2730

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOT HILL 2730 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag