[. . . ] Dot Hill 3120 and 3130 JBOD Expansion Arrays 3130 Expand your SAN as your Business Grows with easy, scalable tiered storage As your need for storage increases, Dot Hill provides an easy to deploy and cost ef fective way to extend your fibre channel, SAS or iSCSI SAN. [. . . ] These units easily expand the capacity of a customer's SAN. The 3120 or 3130 JBOD array is controlled by the RAID controller of the primary unit and allows SAN expansion at a lower cost than a full RAID array. Scalable Performance · up to 7 expansion units per system · max 144 drives - 3120, 96 - 3130 Rugged Chassis NEBS Levell 3 Compliant MIL STD 810F Compliant ( Storage Requirements) European Telco Compliant Use the 3120 with. . . The 3120 JBOD expansion units can be deployed with Dot Hill's 2. 5-inch RAID storage arrays: 3720 8Gb Fibre Channel Storage Array 3920 8Gb Fibre Channel & 1Gb iSCSI Storage Array Use the 3130 with. . . The 3120 JBOD expansion units can be deployed with Dot Hill's 3. 5-inch RAID storage arrays: 3730 8Gb Fibre Channel Storage Array 3930 8Gb Fibre Channel & 1Gb iSCSI Storage Array 3120 24-DRIVE ARRAY FEATURES ····························· 3130 12-DRIVE ARRAY FEATURES ··························· Drive size Drives per array Max capacity per chassis PHYSICAL 2. 5-inch drives up to 24 12TB Drive size Drives per array Max capacity per chassis PHYSICAL 3. 5-inch drives up to 12 24TB ······························································· ······························································· Depth (excluding cables) Height Width Chassis weight w/146GB drives 21. 3 Inches / 54. 0 cm 3. 5 Inches / 8. 9 cm 17. 6 Inches / 44. 7cm 44 lbs / 20kg 60 bs / 27. 2kg Depth (excluding cables) Height Width Chassis weight w/500GB drives 23. 7 Inches / 60. 2 cm 3. 5 Inches / 8. 9 cm 17. 6 Inches / 44. 7 cm 44lbs. / 30. 84kg www. dothill. com 3120/3130 JBOD specifications GENERAL ································································ DECLARED ACOUSTIC NOISE LEVELS . . . . . . . . . . . . . . . . . . . . . . . . Sound Power Sound Pressure Shock, Operational Shock, Non-Operational Vibration, Operational Vibration, Non-Operational LWAd=6, 75 B LpAm - 55dB 10G's for 10 ms (3720) 5G's for 10 ms (3730) 15G 11ms, half sine 5Hz to 500Hz, 0. 21Grms flat spectrum 3-365-3Hz, 1. 22 Grms, z-axis, 0. 85 Grms, X&Y axis shaped spectrum ··································· Product Family Product Type Chassis Configuration Disk Architecture Data Management Services (DMS) 3000 Series JBOD 2U 6Gb SAS AssuredRemoteTM AssuredSnapTM, AssuredCopyTM SHOCK AND VIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DRIVES ··································································· Drive Types SAS, SATA, SSD HIGH-AVAILABILITY FEATURES RAID ···································································· Levels Supported RAID Type Cache Memory Cache Backup Virtual disks per System Volumes per virtual disk Volumes per System Mirrored Cache Super Capacitor Cache Backup Cache Backup to Flash 0, 1, 3, 5, 6, 10 and 50 Hardware 2GB per controller Battery-free protection with super capacitors 64 256 256 Yes - SimulCacheTM Yes Yes - Non-volatile Redundant Hot-Swap Controllers Redundant Hot-Swap Disk, Fans, Power Dual Power Cords Hot Standby Spare Automatic Failover Multi-Path Support Snapshot with AssuredSnapTM Volume Copy with AssuredCopyTM Remote Replication with AssuredRemoteTM Yes Yes Yes Yes Yes Yes Yes Yes Yes REGULATORY Safety ··························································· MANAGEMENT ························································· SAS connect to RAID UL 60950-1, 1st edition, 2007-10-31 (USA) CAN/CSA-C22. 2 No. 60950-1-03, 1st Edition, 2006-7 (Canada) EN 60950-1:2006 (European Union) EC 60950-1:2001 (International) EN 60950-1:2001 +A11:2004 (GS Mark, , Germany) CCC Mark (power supply only, China PRC) CFR 47 Part 15 Subpart B Class A (U. S. A. ) ICES-003:2004 Class A (Canada) EN 55022:2006 +A1:2007 Class A (EU) EN 300 386 V1. 4. 1:2008 Class A (EU Telco) AS/NZS CISPR 22:2009 Class A (Australia, New Zealand) VCCI:2009-04 Class A (Japan) GOST R 51318. 22-99 Class A (Russia) KN 22 Class A (S. Korea) CNS 13438:2006 Class A (Taiwan) EN61000-3-2:2006 (EU) EN 61000-3-3:1995 +A1:2001+A2:2005 (EU) EN 55024:1998 +A1:2001+A2:2003 (EU) EN 300 386 V1. 4. 1:2008 (EUTelco) GOST R 51318. 24-99 (Russia) KN 24 (S. Korea) RoHS-6/6 Compliance, China RoHS, WEEE United States, Canada, European Union (EU), Australia/New Zealand, Japan, China (PRC) , Russia, Mexico, South Africa, Germany, South Korea, Taiwan Electromagnetic Compatibility Emissions POWER REQUIREMENTS - AC INPUT Input Power Requirements Max Input Power Heat Dissipation ··························· 100-240VAC 50/60Hz 436W max maximum continuous 1488 BTUs/hour ··························· POWER REQUIREMENTS - DC INPUT Voltage Max Input Power Heat Dissipation -36 to -72VDC, -48/-60V nominal 436W maximum continuous 1488 BTU/hour TEMPERATURE AND HUMIDITY RANGES . . . . . . . . . . . . . . . . . . . Operating Temperature Shipping Temperature 41°F to 104°F (5°C to 40°C) -40°F to 158°F (-40°C to 70°C) Note: Derate 2°C for every km, up to 3000 meters 10% to 90% RH @ 104°F (40°C), non-condensing Up to 93% RH @ 104°F (40°C) non-condensing Harmonics Flicker Immunity Operating Humidity Non-Operating Humidity RoHS and WEEE Country Approvals SUPPORT ································································ Software Warranty Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion 90 days 3 years SNMP, CLI, RAIDar 2. 0, SMTP, SMI-S Provider Yes Yes Yes Yes for primary volumes and snapshot volumes and snapshots © 2009, Dot Hill Systems Corp. , All rights reserved. Dot Hill, the Dot Hill logo, AssuredRemote, AssuredSnap, AssuredCopy, EcoStor and SimulCache are all trademarks of Dot Hill Systems Corp. [. . . ] No part of this document may be copied or reproduced without written permission of Dot Hill Systems Corp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DOT HILL 3130

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DOT HILL 3130 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag