Detailed instructions for use are in the User's Guide.
[. . . ] S S A N n t ®t ® I I F C 3 2 0 ANne e I I U
· · · · · · · · · · · · · · · · · ·
SPECIFICATION SHEET SPECIFICATION SHEET
Powerful, rack-dense, scalable, super-rugged Fibre Channel RAID disk array.
· Adapts to your unique requirements. [. . . ] RAID arrays can be quickly scaled to over 32TB of raw capacity. Our efficient storage design allows you to store over 116TB in a single 42U rack. · Highly ruggedized array meets full NEBS Level 3 certification and complies with MIL-STD-810F specifications.
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
The powerful 2Gb SANnet II FC array provides a modular, building-block approach and high port counts to help reduce costs. Up to four dual-path or eight single path servers can be connected to a dual controller tray without using costly switches and extra cabling. With its highly intuitive management interface, this array is extremely easy to deploy, configure, manage, and monitor. With affordable, enterprise-class features and functionality, the SANnet II FC array leads the industry with dual hot-swap power and cooling, hot-swap redundant RAID controllers with mirrored cache, hot-swap disk drives, global and local hot sparing, dynamic LUN expansion, dynamic capacity expansion, non-disruptive firmware code loading, and remote status monitoring.
· · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ª ·
Adaptable.
spec
SANnet II FC Specifications
GENERAL
································································
Product Family Product Type Chassis Configuration Storage Architecture Supported Hosts Total Capacity Total Disks Mounting Options Max Number of Chassis Max Capacity per Chassis
SANnet II RAID, JBOD 2U, 12 drives SAN or DAS Up to 64 Up to 32. 4TB with 300GB FC drives Up to 108 FC; or up to 72 mixed SATA & FC Rack mount 9 (1 RAID and 8 JBOD) 3. 6TB (300GB FC drives) 6TB (500GB SATA drives)
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
ENVIRONMENTAL - OPERATING
Temperature Humidity Altitude Shock Vibration Noise Heat
·······························
5°C to 40°C (41°F to 104°F) 10% to 90% 27°C (81°F) non-condensing -30m to 3048m (-100ft to 10, 000ft) 5. 0G, 11ms, half-sine 0. 2G, 5-500Hz, swept-sine Less than LwAd 6. 7B (65 dBA) 1200 BTU/hour
· ······················
ENVIRONMENTAL NON-OPERATING
Temperature Humidity Altitude Shock Vibration
HOSTS
···································································
· · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
Host Connection Interface Type External Ports
4/8 Ports - Fibre Channel 2 Gbit Fibre Channel 4 per expansion JBOD
--40°C to 65°C (--40°F to 149°F) 0% TO 90% 38°C (100°F) non-condensing -30m to 12, 192m (-100ft to 40, 000 ft) 15. 0G, 11ms, half-sine 1. 0G, 5-500Hz, swept-sine
·································
HIGH-AVAILABILITY FEATURES
Redundant Hot-Swap Controllers Redundant Hot-Swap Disks Redundant Hot-Swap Fans Redundant Hot-Swap Power Dual Power Cords Multiple Hot Standby Spare Automatic Failover Alternate Pathing Yes Yes Yes Yes Yes Yes Yes Yes
DRIVES
··································································
Max Number of Drives Drive Options
108 FC 73GB, 146GB or 300GB at 10, 000 RPM FC 36GB, 73GB or 146GB at 15, 000 RPM SATA 250GB or 500GB at 7, 200 RPM
RAID
······································································
Levels Supported RAID Type Cache Memory Cache Backup Arrays per System Partitions per Array Volumes per System Mirrored Cache Battery Cache Backup Flash Cache Backup
0, 1, 3, 5, 10, 30, 50 or JBOD Hardware 1GB per controller Battery, 72 hours 1 to 32 1 to 32 1 to 1024 Yes Yes Yes
······················································
· · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
REGULATORY
Safety Emissions
··························································
Harmonics and Flicker Immunity Other Country Approvals
MANAGEMENT
Interface Types Protocols Supported Management Consoles Management Software
Serial, Ethernet, FC SMI-S 1. 02, SNMP, API JAVA, GUI, CLI, API Dot Hill SANscape with MPIO support
UL listed, cUL, CSA-C22. 2 EN 60950:2000, IEC 60950, GS, S-Mark FCC Part 15 Class B, ICES-003, EN 300-386, EN 55022 Class B, VCCI Class B, AS/NZS 3548, Class B, BSMI Class B EN 61000-3, EN 61000-3-3 EN 300-386, EN 55024 NEBS Level 3 (GR-63; GR-1089) MIL-STD-810F, ETSI EN 300 019 USA, European Union (EU), Canada, Argentina, Taiwan, Japan, Australia 2 Years Yes, via SMI-S, SNMP, CLI, API Yes Yes Yes Yes
SUPPORT
································································
· · · · · · · · ·
· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·
ELECTRICAL AC INPUT
Voltage Current Power
·········································
100-240 VAC @ 50/60Hz, single phase 10A maximum per input 360W typical
Standard Hardware Warranty Environmental Monitoring Phone-home Capability Remote Diagnostics Non-disruptive Updates Non-disruptive Volume Expansion
PHYSICAL
·······························································
ELECTRICAL DC INPUT
Voltage Current Power
·········································
-36 to -72 VDC, -48v nominal 20A maximum per input 360W typical
Height Depth Width Chassis Weight Chassis w/Drives Weight
8. 75cm (3. 45 inches) 53. 3cm (21. 0 inches) 44. 7cm (17. 6 inches) 27. 2kg (60lbs. ) 34. 0kg (75lbs. )
· · · · · · · · · · ·· · · · · · · · · ·· · · ·
Corporate Headquarters: 2200 Faraday Avenue, Suite 100 Carlsbad, CA 92008 USA 800-872-2783 760-931-5500 Fax: 760-931-5527
Europe: Marssteden 94 7547 TD Enschede THE NETHERLANDS 31-53-428-4980
Asia-Pacific: Chiyoda Trade Ctr. , Bldg. [. . . ] Specifications and features may change without notice. [. . . ]