Manual abstract: user guide DSC CLASSIC PC585INSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] WARNING
This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
Installation Manual
Software Version 2. 3 / DLS-1 v6. 7 and up
See Back Cover for New Features in Version 2. 3
WARNING
Please Read Carefully
Limited Warranty
Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security Controls Ltd. [. . . ] NOTE: Any zone with the wireless attribute enabled will not cause an alarm for a fault condition when armed (or any time for 24-hour zones). Sections [101] - [108]: [1] - [8]
5. 4
Assigning Keypad Zones
"Z" keypads have zone inputs to which devices--such as door contacts--can be connected. (See 2. 11 "Keypad Zones" on page 6 for wiring information. ) Once the keypad zones are installed, assign the zone in programming section [020] Keypad Zone Assignments. Enter the 2 digit zone designated for each keypad (slot) from 01-08. [020]
5. 5
Communicator Dialing
If the Communicator Disable option is selected, the panel will not attempt to call central station. If communication is enabled, the panel will attempt to call central station when an event with a valid reporting code occurs. (See 5. 8 "Communicator Reporting Codes" on page 18. ) The Communicator Call Direction options are used to select which telephone number the panel will dial when an event occurs. If the DTMF Dialing option is enabled, the panel will dial using DTMF (touch tone). If the Switch to Pulse Dial option is enabled, the panel will switch to pulse dialing on the fifth attempt to call the central station. When this option is disabled, the panel will always dial using DTMF. If DTMF Dialing is disabled, the panel will always pulse dial. When the Force Dialing option is enabled, the panel will dial out regardless of the presence of dial tone. Each dialing attempt will follow this pattern: a) the panel picks up the telephone line and searches for dial tone for 5 seconds b) if no dial tone is found, the panel hangs up and waits for 20 seconds c) the panel picks up the telephone line again and searches for a dial tone for 5 seconds d) the panel will then dial regardless of the presence of dial tone If there is no initial handshake recognized within 40 seconds the panel will then hang up the line. If the Force Dialing option is disabled, each attempt will still follow the above pattern, except that the panel will not dial in step d if no dial tone is detected. The Delay Between Dialing Attempts timer adds a delay before the next call is dialed. If the Busy Tone Detection option is enabled, the panel will hang up after detecting busy tone for 5 seconds and will
redial after the amount of time programmed in the Delay Between Dialing Attempts section. Maximum Dialing Attempts determines the maximum number of attempts the panel will make to send a signal to the central station before indicating a Failure to Communicate (FTC) trouble condition. The 3rd Telephone Number can be used to back up the 1st in this situation. (See 5. 7 "Communicator Telephone Numbers" on page 17. ) If a later communication attempt is successful, the FTC reporting code(s) programmed in section [351] will be transmitted along with the unreported events from an earlier unsuccessful communication. When Bell on FTC when Armed is enabled in programming section [702], option [8], an FTC during the armed period will sound an Audible Alarm for the length of Bell time-out or until the system is disarmed. If FTC Trouble Only when Armed is enabled, only the keypad buzzer will sound trouble beeps every 10 seconds until a key is pressed. Post Dial Wait for Handshake determines the amount of time the panel will wait for a valid handshake from the receiver. [. . . ] Enter the Number corresponding to the label to be programmed. · Use the arrow keys (<>) to move the underline bar underneath the letter to be changed. · Press the number key [1] to [9] corresponding to the letter you require. The first time you press the number the first letter will appear. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC CLASSIC PC585
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.