User manual DSC LC-124-PIMW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DSC LC-124-PIMW. We hope that this DSC LC-124-PIMW user guide will be useful to you.

Lastmanuals help download the user guide DSC LC-124-PIMW.


Mode d'emploi DSC LC-124-PIMW
Download
Manual abstract: user guide DSC LC-124-PIMW

Detailed instructions for use are in the User's Guide.

[. . . ] The effective detection range is the range of which the patterns (PIR & MW) are intersected. the GAIN potentiometer adjustment changes the MW signal intensity so that the effective pattern will be scaled. This Installation Manual shall be used in conjunction with the Installation Manual of the ALARM Control Panel. [. . . ] If the front cover of the detector is opened, an immediate alarm signal will be sent to the control unit. Note: The detector shall be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply. When an intrusion is detected, the alarm relays will switch into alarm condition for 2 sec. Position Down "OFF" (2 Pulses) - High sensitivity for stable environments PET IMMUNITY SETTING Switch 4 of dipswitch marked "PET" ­ provides setting for pet weight 15kg (33lbs) or 25kg (55lbs) Position Up "ON" - Immunity to an animals up to 15 kg (33lbs) Position Down "OFF" - Immunity to an animals up to 25kg (55lbs) Note: Pet immunity feature has not been tested by UL. Ouvrez les trous désirés pour l'installation (Fig 1 -2) pour le support plat ou (Fig 1 -3) pour le support d'angle. For ULC Installations use PIR pulse count set to AUTO (DIP 2 is OFF) and AND/OR function set to AND mode (DIP 5 to OFF) Position Up "ON" ­ OR mode ­ the ALARM relays will activate as a function of PIR OR MW detection ( The first channel that detects will activate the ALARM) Position Down "AND" ­ AND mode ­ the ALARM relays will activate as a function of both PIR AND MW detection. NOTE: Detector must be restart by temporary remove power before the new settings will take effect. rANGE CALIBRATION The "MW" potentiometer (Fig. 5-4) adjusts the MW detection range between minimum and maximum (factory set to middle position). NOTE: The "MW" and "PIR" potentiometer may need to be adjusted to the Maximum positions in order to achieve maximum area of coverage as indicated in Fig. Use the following table to determine required wire gauge (diameter) and length of wire between the detector and the control panel. 656 984 1312 2624 Wire Gauge AWG 22 20 18 16 WALK TESTING IMPORTANT NOTE: Upon installation, the unit should be thoroughly tested to verify proper operation. The end user should be instructed on how to perform a walk test weekly. Make sure detector has been set up: Pulse=1, LED=ON and protected area cleared of all people. Create motion in the entire area where coverage is desired, observe the Green LED for PIR detection, and Yellow LED for MW detection. should the coverage be incomplete , readjust range or relocate the detector. Once coverage is as required, the alarm LED may be disabled. Use the optional LC-L1ST wall mount or ceiling mount brackets to solve placement problems. [. . . ] ) could void the user's authority to operate the equipment. This device complies with part 15 of the FCC rules. Operations are subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC LC-124-PIMW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC LC-124-PIMW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag