Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DUCATI CTR32. We hope that this DUCATI CTR32 user guide will be useful to you.
Lastmanuals help download the user guide DUCATI CTR32.
Detailed instructions for use are in the User's Guide.
[. . . ] Any inaccuracies or errors found in this manual will be corrected in the next edition. Electronic board controlling 1 or 2 230 Vac single-phase asynchronous motors for the automation of a single or two-wing gate. Caution : Before operating the electronic unit make sure the following operations have been carried out. Note 1 Note 2 Note 3 Note 4 Note 5 Note 6 Note 7 Note 8 Note 9 Note 10 Note 11 Note 12 Note 13 Note 14 Note 15 Caution: Read carefully the whole technical documentation supplied. [. . . ] Dip switch 1 It chooses whether the unit will operate in the mode determined by dip-switch 2 or in condominium mode : ON=Condominium OFF=No effect Dip switch 2 It chooses whether the unit will operate in step-by-step mode or in automatic mode : ON =Automatic OFF=Step by step Dip switch 3 It enables the operation with a single-wing gate : ON=Single wing OFF=Double wing Dip switch 4 It enables or excludes the kickback (during the opening phase with closed gate) and extra-push (during the closure phase) procedures : ON= Kickback enabled OFF=No effect Dip switch 5 It enables or excludes the delay between the wings' starts : ON= 0 sec Delay OFF=Delay enabled P1 Allows to insert/cancel the radio-command codes in the memory P2 Allows to set the motors' work time and the M2 motor's closing delay time P3 Allows to set the pause time F1 Mains power fuse (5A) It disconnects the electronic unit from the power supply mains in case of short-circuit or electric current consumption anomalies. F2 Low voltage fuse (1A) It protects the electronic unit in case of short circuits or overcurrents on photo-cells, electric lock or any other accessory devices connected to the 24 Vac power supply Power regulator Regulating the RV1 trimmer it is possible reduce the power supplied to the motors during the normal speed phase. Caution: In case failure or anomaly of the power regulator card the motors may operate at their maximum power value. This is why n° 7 note in the previous chapter "limits to use" must absolutely be put into practice. Starting of maximum start up power When any of the motors starts the unit supplies the maximum power value for approx. Radioreceiver The electronic unit contains a two-channel radio receiver allowing remote control of the gate by means of the radio transmitter. the radio receiver channel 1 acts as Start control and channel 2 acts as Pedestrian start. The radio receiver operates with a self-learning logic and can store up to 12 different codes from the radio-commands. Each code may be addressed on the desired channel (Start or Pedestrian start). The memory contents is preserved in absence of power supply. The memory contents may be erased (total cancellation). in alternative the electronic unit is pre-set for the optional connection of an accessory radio receiver card. The channel 1 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the start input. The channel 2 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the pedestrian start input. Quick flashing light : it signals the opening phase Slow flashing light : it signals the closing phase Fixed light : it signals that the gate is blocked in wait that the obstacle that covers the photocell or photostop to be removed. Open gate lamp The electronic card controls a lamp that displays the gate's position. The lamp is off when the gate is completely closed and is lit in all other cases. Work time The motors' work time is controlled by two independent digital timers. If any command interrupts the wing's travel before its end, the Timer stops and the elapsed time is stored in memory. Therefore the unit can determine, with a fair approximation, the partial working time necessary to the wing to end its travel. Thanks to this feature it is possible to avoid that the motor works for a long time after the end of the wing's travel, thus reducing overheating to the minimum. Warning : In case of absence of power supply the stored position will be lost. [. . . ] The pedestrian start command has no effect during a start cycle and up to the end of the closing phase (closed gate). During a pedestrian start cycle the start command is always active and causes the start of an opening cycle for both wings. Dimensions and weight : 177 x 247 x 92 mm - 1, 2 Kg Mains power supply : 230 Vac +/- 10% Stand-by power consumption : approx. 1 W Operating temperature range : 0 to + 60 °C Single-phase motors power supply : 230 Vac 1 HP max Blinker power supply : 230 Vac 40 W max Courtesy light power supply : 230 Vac 40 W max Open gate lamp power supply : 230 Vac 40 W max Electric lock power supply : 12 Vac 15 W max Accessories power supply : 24 Vac 0. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DUCATI CTR32
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DUCATI CTR32 will begin.