Manual abstract: user guide DURKOPP 120-37SPARE PARTS
Detailed instructions for use are in the User's Guide.
[. . . ] In no event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document.
Printed: December 2010 in Bielefeld, Germany
Operating manual part II
Contents
PART II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1
1. 1 1. 1. 1 1. 1. 2 1. 1. 3
Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parameter of class 272. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operator-level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Technician-level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Developer-level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
© 2010 Dürkopp Adler AG
II-3
Operating manual part II
PART II 1 Parameter
The parameter overview is help a sought-after parameter for finding fast and changing. The construction of the list has already been explained in the list using structure. [. . . ] There are parameters, which can be found in the technicians' and developers' level both different consequences, however, have. All settings in the developers' level aren't accessible for using staff and service technicians but are adjusted by the software developers to the certain hardware once.
1. 1
t 08 04
Parameter of class 272
class: set of parameters: for sub-class: 272 272-140342-01 272-140342-01
1. 1. 1
L C
Operator-level
P Min Max Preset Unity Description
Bobbin thread counter and bobbin thread monitor o 06 00 0 4 0 Activate the bobbin thread counter 0 = off; 1 = Bobbin thread counter A; 2 = Bobbin thread counter B; 3 = Bobbin thread counter C; 4 = Bobbin thread monitor o 06 01 0, 1 999, 9 300, 0 x o0602 Reset value of the bobbin thread counter A o 06 02 0, 1 999, 9 200, 0 x o0604 Reset value of the bobbin thread counter B o 06 03 0, 1 999, 9 100, 0 x o0604 Reset value of the bobbin thread counter C o 06 04 1 255 10 x stitches Factor of the bobbin thread counter A, B, and C o 06 05 0 9999 0 stitches Number of stitches for bobbin thread monitor o 06 06 0 1 0 Stopping motor if the counter has reached the value 0. 0 = off; 1 = on o 06 07 0 1 0 Sewing foot down after thread trimming. 0 = off; 1 = on o 06 08 0 1 0 Display of the bobbin thread counter value 0 = off; 1 = on Needle cooling o 13 00 0 1 0 Needle cooling 0 = off; 1 = on
II-4
© 2010 Dürkopp Adler AG
Operating manual part II
1. 1. 2
Technician-level
The technician's level is unlocked by the following key combination: When switching on the control unit and press the P button time. This allows access to the technician's level. Press A+ to get into the technician's level.
L CP Backtack t 00 00 t 00 01 t t 00 00 02 03 Min 300 0 0 0 Max 2500 254 254 1 Preset 1700 12 14 0 Unity rpm 10° 10° Description Start backtack speed Pre-control angle when switchin g on the backtack magnet. (Switchover of forward backward at the bartack) Pre-control angle when turning th e backtack magnet off. 0 = Position -2; 1 = Position -1 on switching angle t 08 12 <= t 02 10 < t 02 11 off switching angle t 02 10 < t 02 11 <= t 08 13 Delay time for a repeated activation of the Cutting magnet. Delay time for turning the cutting magnet off sewing foot lifting active 0 = No; 1 = Yes Intermediate lag of the machine after switching the sewing foot lifting off Turn-on delay of the sewing foot lifting at speed 0 Turn-on delay of the sewing foot lifting at the seam end Drive time of the sewing foot lifting magnet in the time period t1 Pulse duty ratio in the time period t1 Drive time of the foot lifting magnet in the time period t2 (If you adjust 0s the thread clamp magnet will be driven permanently) Pulse duty ratio in the time period t2 Increasing Umag when the foot lifting magnet will be driven 0 = No; 1 = Yes Soft start speed Number of soft start stitches
t t t t t t
03 03 03 03 03 03
10 11 12 50 51 52
0 0 0 0 5 0, 0
255 255 255 999 100 600, 0
80 40 80 200 100 300, 0
ms ms ms ms % s
t t
03 03
53 54
5 0
100 1
43 1
% -
Soft start t 05 00 t 05 01
120 1
1000 99
800 2
rpm Stitches
II-8
© 2010 Dürkopp Adler AG
Operating manual part II
L CP Seam ways t 07 00
Min 0
Max 2
Preset 0
Unity -
Description Treatment position-2 in seam ways. The next seam way is sewn; The seam is broken off with thread trimmer at the last seam of the program. 1 = Demolition of the seam with thread performances (even if inactive). 2 = Demolition of the seam with thread performances (even if inactive). 0 = off; 1 = on Maximum speed Minimal speed Positioning speed Acceleration ramp Braking ramp Direction of rotation of the motor 0 = on the left; 1 = on the right Motor brake at the normal stop 0 = Brakes for the duration of t0805; 1 = Brake durably actively at the stop 2 = Position will be hold permanently Holding current at the machine stop Reaction rate at changes of the needle position Period of the motor brake Setting the reference position Setting the needle positions Lower needle position (Position 1) Thread lever up position (Posit ion 2) Direction finder position on threading position Calibrating pedal Number of speed steps of the pedal Speed curve Debouncing of the position-1 Debouncing of the position-2 Shows the machine speed 0 = No; 1 = Yes Shows the current needle position 0 = No; 1 = Yes The Needle will move to the upper needle position if the energy is on and the pedal was used. 0 = No; 1 = Yes Speed limitation DB3000
t
07
01
0
1
0
-
Motor t 08 t 08 t 08 t 08 t 08 t 08
00 01 02 03 04 05
500 100 100 1 1 0
9999 400 1000 100 100 1
4800 180 180 30 35 0
rpm rpm rpm rpm/ms rpm/ms -
t
08
06
0
2
0
-
t t t t t t t t t t t t t t t
08 08 08 08 08 08 08 08 08 08 08 08 08 08 08
07 08 09 10 11 12 13 14 15 20 21 22 23 24 30
0, 1 0 0 0 0 0 0 12 0 10 5 0
6, 0 255 999 359 359 359 359 64 4 255 255 1
2, 0 20 200 41 306 350 296 24 1 90 15 0
A ms ° ° ° ° Steps ms ms -
t
08
31
0
1
0
-
t
08
32
-
-
-
-
t
08
40
500
9999
1800
rpm
© 2010 Dürkopp Adler AG
II-9
Operating manual part II
L CP Min Thread tension t 09 00 0
Max 3
Preset 0
Unity °
Description Mode of the thread tension release and thread tension reduction with active foot lifting. [. . . ] 0 = No; 1 = Yes Speed limitation DB3000
t
07
01
0
1
0
-
Motor t 08 t 08 t 08 t 08 t 08 t 08
00 01 02 03 04 05
500 100 100 1 1 0
9999 400 1000 100 100 1
4800 180 180 30 35 0
rpm rpm rpm rpm/ms rpm/ms -
t
08
06
0
2
0
-
t t t t t t t t t t t t t t t
08 08 08 08 08 08 08 08 08 08 08 08 08 08 08
07 08 09 10 11 12 13 14 15 20 21 22 23 24 30
0, 1 0 0 0 0 0 0 12 0 10 5 0
6, 0 255 999 359 359 359 359 64 4 255 255 1
2, 0 20 200 41 306 350 296 24 1 90 15 0
A ms ° ° ° ° Steps ms ms -
t
08
31
0
1
0
-
t
08
32
-
-
-
-
t
08
40
500
9999
1800
rpm
© 2010 Dürkopp Adler AG
II-9
Operating manual part II
L CP Min Thread tension t 09 00 0
Max 3
Preset 0
Unity °
Description Mode of the thread tension release and thread tension reduction with active foot lifting. 0 = No thread tension release; 1 = Thread tension release in the seam; 2 = Thread tension release after thread trimming; 3 = Thread tension release in the seam and after thread trimming. Thread tension release by thread he lp 0 = No; 1 = Yes Delay time of the tread tension release after thread trimming. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DURKOPP 120-37 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DURKOPP 120-37 will begin.