User manual DYNACORD DSP 260

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNACORD DSP 260. We hope that this DYNACORD DSP 260 user guide will be useful to you.

Lastmanuals help download the user guide DYNACORD DSP 260.


Mode d'emploi DYNACORD DSP 260
Download

You may also download the following manuals related to this product:

   DYNACORD DSP 260 BROCHURE (5994 ko)
   DYNACORD DSP 260 DATASHEET (703 ko)
   DYNACORD DSP 260 SOFTWARE V1.4.0 (61 ko)

Manual abstract: user guide DYNACORD DSP 260

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL DSP 260 Overview. Free Configuration - Full Edit 2 In 6 Out . 4 6 6 8 8 12 14 17 17 17 17 17 18 18 18 18 19 19 19 19 20 21 21 30 30 34 35 36 37 38 39 40 41 42 44 45 46 46 46 47 47 48 48 49 49 50 2 Owner`s Manual DSP 260 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficent magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. 1. [. . . ] Empty locations will display "?" in the name field. You may select an empty location, or a location of a preset that will be over-written. Press the < Select > buttons to navigate down to the preset name field. Use the Value Up and Down buttons to select the field for each letter / symbol character. The DSP 260 provides the complete ANSI character set, including lower-case & upper-case letters, numerals and symbols. Pressing and holding the Value Up and Down buttons will scroll rapidly through the character set. Press the < Select > buttons to move to the next or previous character position. When the preset is named, press Store again. If the preset location was previously empty, the display will prompt "Are you sure?If you are overwriting an existing preset the display will prompt "Overwrite Preset?In either case, press Store again to proceed and store the new preset. To Exit Store without saving the edited preset, press the Edit, Setup or any of the DSP block buttons. (Edit or Setup buttons will return the display to run-time mode. DSP block buttons will display the corresponding DSP block edit screen. ) 20 Owner`s Manual DSP 260 5. 9 Edit Both Factory and User preset can be edited, but edited presets can only be stored in User preset locations. Standard Edit Mode The DSP 260 defaults to Standard Edit mode wherein, input and output channel parameters are appropriately linked. (Refer to "Configurations" illustrations to see which channels are parameter-linked for each configuration. Linked parameters are always identical in value. For instance, setting a graphic eq curve for Input A, sets the same curve for Input B, if the configuration has linked stereo inputs. Either input channel can be edited; changes will be reflected in both. The same is true for parameters of linked output channels. The only exception to the linking of parameters is the Mute buttons. Output channels can be individually muted at any time, either from the DSP 260 front panel or the Graphic User Interface application. Full Edit Mode In the Setup menu, the edit mode can be changed to Full Edit. In Full Edit, no parameter links are enforced, regardless of the configuration selected. [. . . ] Crossover channels are fed from IN A, full range channels are fed from IN B. OUT 1 is a mono Sub frequency channel, OUT 2 the mono Very Low-frequency, OUT 3 is the mono Low-frequency channel, OUT 4 is the mono Mid-Frequency channel , OUT 5 is the mono High-frequency channel and OUT 6 is the Full-range channel. Note: On Input channels, all Parametric EQ and Graphic EQ parameters are not linked. For Output channels, linking applies to Crossover Highpass and Lowpass filters (see page 42 for details). 38 Owner`s Manual DSP 260 7. 5 Free Configuration - Full Edit 2 In 6 Out In this configuration, all 6 outputs are configured for full range operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNACORD DSP 260

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNACORD DSP 260 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag