Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNACORD LX 3000. We hope that this DYNACORD LX 3000 user guide will be useful to you.
Lastmanuals help download the user guide DYNACORD LX 3000.
Manual abstract: user guide DYNACORD LX 3000REV 11-2010
Detailed instructions for use are in the User's Guide.
[. . . ] The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficent magnitude to constitute a risk of electric shock to persons. install in accordance with the manufacturer's instructions. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or the grounding-type plug. [. . . ] The recessed mounted dB-scaled level controls ensure reliable protection against mechanical damage. These particularly precise, secure to operate detent-potentiometers are located on the front panel. LX power amps provide the opportunity for retrofitting an internal analogue signal processor board with x-over and filter functions. The easily readable LED display provides a quick overview of the power amp's current operational status. The power outputs CHANNEL A, CHANNEL B and BRIDGED OUT are carried out as extremely durable SPEAKON-type connectors. Also located on the rear panel is a Ground-lift switch, which, when needed, helps eliminating ground-noise loops by separating the power amp's enclosure from the circuit ground. In normal operation, all LX power amps are capable of driving loads as low as 2ohms. in MonoBridged mode the allowable minimum load is 4ohms. This owner's manual outlines and explains several other features of your LX power amplifier. Please, make sure to carefully read all of it and mind the instructions. Carefully open the packaging and take out the power amplifier. Next to the power amplifier itself, the package also includes this owner's manual, a mains cord and the warranty certificate. Keep the original invoice, which states the purchase/delivery date together with the warranty certificate at a safe place. Generally, installing or mounting LX power amps should be carried out in a way that guarantees continuously unopposed front-to-rear air circulation. Installation of appliances with opposite air circulation within one cabinet or closed rack shelf system is not recommendable. When including appliances in a closed cabinet or rack shelf system make sure to provide sufficient ventilation. Leave a gap of at least 60mm x 330mm (up to the cabinet's top ventilation louvers) for air circulation between the rear of the power amplifier and the cabinet's/rack's rear inner wall. Make sure to leave at least 100mm of space above the cabinet or rack shelf system. Since temperatures inside of the cabinet or rack shelf system can easily rise up to 40°C during operation, bearing in mind the maximally allowable environmental temperatures for all other appliances installed in the same rack shelf system is mandatory (also refer to "MAINS OPERATION AND RESULTING TEMPERATURE"). caution: For trouble-free operation exceeding the maximally allowable environmental temperature of +40°C is not permissible. To prevent the front panel from bending, the use of installation rails or optionally available "rear-rackmount" rails is obligatory when installing the appliance in a rack shelf system or cabinet. The power amplifier has to be protected against: dripping or splashing water, direct sunlight, high temperatures or direct influence of heat sources, high humidity, extensive dust and vibrations. [. . . ] The regular output voltage of each amplifier channel A + B is still present at the corresponding output connectors CHANNEL A and CHANNEL B. However, using these signals is not recommendable because of the aforementioned phase inversion. Operating the power amp in Bridged Mode with loads of 2ohms connected is not allowable. CAUTION: Operating the power amplifier in Bridged-Mode may result in extremely high voltages being present at the BRIDGED OUT connector. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNACORD LX 3000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNACORD LX 3000 will begin.