If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL. We hope that this DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL user guide will be useful to you.
Lastmanuals help download the user guide DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL.
Manual abstract: user guide DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL
Detailed instructions for use are in the User's Guide.
[. . . ] EL/GL SERIES (Mach 2. 0) CONTROL WITH ML700 PANEL
Note regarding EL and GL systems: Mach 2. 0 EL and GL systems function identically, but conform to different International requirements. This reference card will refer to EL systems for the sake of simplicity, but the information given applies to both EL and GL products.
The ML700 panel can be used with the EL8000, EL5000, EL2000 and EL1000 systems. This reference card lists all features that are available. Your spa may not respond as described in this document as specific operation varies by system and equipment used. [. . . ] The "ECONOMY" icon will display until mode is changed. Pressing "Jets 1" while in Economy mode puts the spa in Standard-In-Economy mode, which operates the same as Standard Mode, then reverts to Economy Mode automatically after 1 hour. During this time, a press of the "Mode/Prog" button will revert to Economy Mode immediately. Sleep mode heats the spa to within 20°F (11°C) of the set temperature only during filter cycles. The "SLEEP" icon will display until mode is changed.
Circ Pump (optional)
If your system is equipped with a circ pump, it may be configured to work in one of three different ways: 1) The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1. 5°C) above the set temperature (most likely to happen in very hot climates). 2) The circ pump stays on continuously, regardless of water temperature. 3) The circ pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when the blower or another pump is on.
Standby Mode
Pressing "Warm" or "Cool" then "Jets 2" will turn off all spa functions temporarily. Press any button to exit Standby mode.
Jets 1
Press the "Jets 1" button once to turn pump 1 on or off, and to shift between low and high speeds (if equipped). If left running, the low speed turns off after 2 hours and the high speed turns off after 15 minutes. * On non-circ systems, the low speed of pump 1 runs when the blower or any other pump is on. It may also activate for at least 2 minutes every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if needed, depending upon mode. When the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started.
Preset Filter Cycles
On all systems, the pump and the ozone generator** will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for 5 minutes.
(The following is specific to all systems that are programmed according time)
There are two filter cycles per day. The start/end times of each cycle are programmable. To program, set time as instructed above, then press "Mode/Prog" to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows: The first filter cycle is automatically activated at 8:00 AM and operates the pump until 10:00 AM. The filter 1 indicator icon will light when filter 1 is running. The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM. The filter 2 indicator icon will light when filter 2 is running.
Jets 2 (optional on EL5000, EL2000 and EL1000) Press the "Jets 2" button once to turn pump 2 on or off, and to shift between low and high speeds if it is a two-speed pump. If left running, the pump will turn off after 15 minutes. * Jets 3 (optional on all EL8000 systems or on EL5000 systems without a blower) Press the "Jets 3" button once to turn pump 3 on or off, and to shift between low and high speeds if it is a two-speed pump. If left running, the pump will turn off after 15 minutes. *
*15-minute timeouts may be changed to 30 minutes and 2-hour timeouts may be changed to 4 hours on some models/installations.
(The following is specific to EL2000 and EL1000 systems that are programmed according to duration rather than time)
The first filter cycle ("day") begins 6 minutes after the spa is powered up. The second filter cycle ("night") begins 12 hours later. [. . . ] The Priming mode will last for up to 4 minutes and then the spa will begin to heat and maintain the water temperature in the Standard mode. After the pump has been running for 2 minutes, the temperature will be displayed. In Economy or Sleep mode, the pump may be off for hours outside a filter. If you wish to see the current spa temperature, either switch to Standard mode or turn Jets1 on for at least two minutes. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNASTY SPAS PARAMOUNT (ELGL) CONTROL WML700 PANEL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.