User manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD. We hope that this DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD user guide will be useful to you.

Lastmanuals help download the user guide DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD.


Mode d'emploi DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD
Download
Manual abstract: user guide DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD

Detailed instructions for use are in the User's Guide.

[. . . ] Press the pad to display the set temperature, and again to make the temperature change in the desired direction. After three seconds, the LCD will stop flashing and display the current spa temperature. Note: If there is not a blower on the system, an alternate panel with separate "Up" and "Down" buttons in place of a "Set" or "Temp" button may be used. Simply press "Up" or "Down" where a "Temp" or "Set" button press is indicated. Mode Mode is changed by pressing the "Temp" or "Set" button, then pressing the "Light" button. [. . . ] In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Aux freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a 4-minute delay in turnoff. See your dealer for details. Blower (optional on VS501 or GS501) This button is used to turn the blower on and off. If left on, the blower automatically turns off after 15 minutes. Jets 2 (optional on VS501 or GS501) If your system has a pump 2 installed instead of a blower, it behaves exactly like a blower would. Light Press the "Light" button to turn the light on and off. If left on, the light automatically turns off after 4 hours. (over) Diagnostic Messages Message Meaning No message on display. "Overheat" - The spa has shut down. One of the sensors has detected 118°F/48°C at the heater. Action Required The control panel will be disabled until power returns. Spa settings will be preserved until next power up. After the circ pump has been running for 2 minutes, the temperature will be displayed. Remove the spa cover and allow water to cool. Once the heater has cooled, reset by pushing any button. If spa does not reset, shut off the power to the spa and call your dealer or service organization. Remove the spa cover and allow water to cool. At 107°F/42°C, the spa should automatically reset. If spa does not reset, shut off the power to the spa and call your dealer or service organization. The pump and blower will automatically activate regardless of spa status. If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools. ) If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools. ) If the problem persists, contact your dealer or service organization. If the water level is okay, make sure the pumps have been primed. If problem persists, contact your dealer or service organization. [. . . ] A significant difference between temperature sensors has been detected. (Displays on the fifth occurrence of " " message within 24 hours. ) Heater is shut down, but other spa functions continue to run normally. Possible inadequate water, poor flow, or air bubbles in detected in the heater. Spa is shut down for 15 minutes. Inadequate water detected in heater. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNASTY SPAS VS500501 GS500501 CONTROL REFERENCE CARD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag