User manual DYNATEK D3K1-5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNATEK D3K1-5. We hope that this DYNATEK D3K1-5 user guide will be useful to you.

Lastmanuals help download the user guide DYNATEK D3K1-5.


Mode d'emploi DYNATEK D3K1-5
Download
Manual abstract: user guide DYNATEK D3K1-5

Detailed instructions for use are in the User's Guide.

[. . . ] Please keep these operating instructions for future reference. Pass them on to possible new owners of the appliance. € Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. [. . . ] Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. In the event of discrete-adjustment knobs with LED visualisation, turn the knob to the minimum power setting them remove it and intervene on the adjustment screw located near the tap pin. Minimum setting adjustment of the DRDA (DCDR) burner with discrete adjustment and LED visualisation: • To adjust the outer ring, turn the knob anticlockwise to the minimum power position. € To adjust the minimum power setting of the inner ring, turn the knob clockwise to the minimum power position. € Remove the knob and intervene on the adjustment screw located near the tap pin. If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres. Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations). 60 72 100x2 20 17 25 86 343 Nominal (mbar) Minimum (mbar) Maximum (mbar) (1) For single-control DRDA (DCDR) burner only (2) For dual-control DRDA (DCDR) burner only * At 15°C and 1013 mbar - dry gas ** Propane P. 10 114x2 390 30 0, 30 0, 90 27 44 65 64 0, 90 69 86 27 1, 50 4, 60 55 44 334 70 x 2 329 5, 00 69 476 113 x 2 Supply pressures Nominal (mbar) Minimum (mbar) Maximum (mbar) 28-30 20 35 37 25 45 20 17 25 (1) For single-control DRDA (DCDR) burner only (2) For dual-control DRDA (DCDR) burner only * At 15°C and 1013 mbar - dry gas ** Propane P. It is possible to turn on only the circular part of the elemement (identified by the letter "A") or the cooking surface * Only available on certain models. GB 24 can be enlarged by turning on both "A" and "B". To turn only the circular "A" element, simply turn the knob in the clockwise direction to any one of the 12 available settings. To add the "B" section, turn the knob to setting 12 and then click it into the setting. Then proceed by turning the knob in the counter-clockwise direction to one of the 12 settings. The figure shows the heating zones, which become red when the element is turned on. Indicator light to show when the cooking zone is above 60°C, even after the heating element has been turned off. Burner Rapid (R) Semi-Rapid (S) Auxiliary (A) Triple Crown (TC) Double Flame (DCDR internal) Double Flame (DCDR external) Ø Cookware Diameter (cm) 24 - 26 16 - 20 10 - 14 24 - 26 10 - 14 24 - 26 GB Pans to be used on 60 - 65 cm hobs Burner Reduced Rapid (RR) Semi-Rapid (S) Auxiliary (A) Semi-Fishburner (SP) Ø Cookware Diameter (cm) 24 - 26 16 - 20 10 - 14 16 - 20 24 - 26 24 - 26 10 - 14 26 - 28 B Triple Crown (TC) Ultra Rapid (UR) A Double Flame (DCDR internal) Oval R ing C Double Flame (DCDR external) Pans to be used on 75 cm hobs When the knob is on any of the settings other than "Off", the Indicator Light for Ceramic Glass Module comes on. Practical advice on using the burners To ensure the burners operate efficiently: • Use appropriate cookware for each burner (see table) so that the flames do not extend beyond the bottom of the cookware. € Always use cookware with a flat base and a cover. € When the contents of the pan reach boiling point, turn the knob to minimum. [. . . ] € Before using the ceramic glass module, the surface must be cleaned, using a damp cloth to remove dust or food residues. The ceramic glass surface should be cleaned regularly with a soultion of warm water and a nonabrasive detergent. Periodically, special products will need to be used to clean the surface. First, remove all food buildup or grease with a cleaning scraper, e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNATEK D3K1-5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNATEK D3K1-5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag