Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DYNATEK DFS1-10P. We hope that this DYNATEK DFS1-10P user guide will be useful to you.
Lastmanuals help download the user guide DYNATEK DFS1-10P.
Detailed instructions for use are in the User's Guide.
[. . . ] Pass them on to possible new owners of the appliance. Also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc. It is advisable to keep only the cylinder being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. [. . . ] connection with a rigid pipe (copper or steel) !Connection to the gas system must be carried out in such a way as not to place any strain of any kind on the appliance. There is an adjustable L-shaped pipe fitting on the appliance supply ramp and this is fitted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe fitting (seal provided with appliance). The hob can only be installed above built-in ovens with a cooling ventilation system. Electrical connection
Hobs equipped with a three-pole power supply cable are designed to operate with alternating current at the voltage and frequency indicated on the data plate (this is located on the lower part of the appliance). The earth wire in the cable has a green and yellow cover. If the appliance is to be installed above a built-in electric oven, the electrical connection of the hob and the oven must be carried out separately, both for electrical safety purposes and to make extracting the oven easier. Connecting the supply cable to the mains Install a standardised plug corresponding to the load indicated on the data plate. The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations). DATA PLATE Electrical see data plate connections This appliance conforms to the following European Economic Community directives: - 2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments - 2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments - 93/68/EEC dated 22/07/93 and subsequent amendments. 78 MJ/m3
A R S
PZ PZ PZ PZ 640/HA 640 GH/HA 640 N/HA 640 GH N/HA PZ PZ PZ PZ 640 640 640 640
A
S
RR S
TC
T/HA T GH/HA T N/HA T GH N/HA
16
Description of the appliance
Overall view
GAS BURNERS
GB
Support Grid for COOKWARE
Control Knobs for GAS BURNERS
SAFETY DEVICES*
Ignition for GAS BURNERS*
• GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most appropriate burner to cook with. Control Knobs for GAS BURNERS adjust the power or the size of the flame. • GAS BURNER ignition* enables a specific burner to be lit automatically. SAFETY DEVICE* stops the gas flow if the flame is accidentally extinguished. The position of the corresponding gas burner is shown on every knob. Gas burners Each burner can be adjusted to one of the following settings using the corresponding control knob: • Off • Always use cookware with a flat base and a cover. Maximum Minimum To light one of the burners, hold a lit match or lighter near the burner and, at the same time, press down and turn the corresponding knob anti-clockwise to the maximum setting. Since the burner is fitted with a safety device, the knob should be pressed for approximately 2-3 seconds to allow the automatic device keeping the flame alight to heat up. [. . . ] This procedure must be performed by a qualified technician authorised by the manufacturer. Do not use abrasive or corrosive detergents such as stain removers, anti-rust products, powder detergents or sponges with abrasive surfaces: these may scratch the surface beyond repair. Never use steam cleaners or pressure cleaners on the appliance. It is usually enough to wash the hob with a damp sponge and dry it with absorbent kitchen roll. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DYNATEK DFS1-10P
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DYNATEK DFS1-10P will begin.