Detailed instructions for use are in the User's Guide.
[. . . ] 15178_DCO7_UK_OPS_MAN_COV_v6
<145mm>
23/11/07
09:27
Page 1
<148mm> <148mm>
DCO7 accessories
The following items can be used with your DCO7. For further information please see the order form, or visit the Dyson website at www. dyson. com
Hard floor tool For improved pick-up on hard floors.
Stubborn dirt brush With stiff bristles for dried-in and stubborn dirt.
5 year guarantee
Register now for your free 5 year guarantee
Flexi crevice tool Extends and flexes into awkward gaps.
Soft dusting brush Soft bristles to gently dust around the home.
Mattress tool Removes dirt and dust mites from mattresses and upholstery.
ONLINE
Just visit www. dyson. co. uk/register
PHONE
7 days a week (UK) 0800 298 0298 (IRL) (01) 475 7109
MAIL
Complete and return the freepost registration form
Mini turbine head Picks up pet hair and dirt from stairs and upholstery.
Low reach floor tool For easier cleaning under low furniture.
Carpet cleaning kit Keeps new carpets looking new.
We'll help you choose the right Dyson cleaner and give you any advice and assistance you need when you're using it. You can contact us anytime at www. dyson. com or call our team of experts on UK 0800 298 0298, IRL 01 475 7109 between 7am and 10pm, 7 days a week.
www. dyson. com
Important
· The plug must be removed from the socket outlet before cleaning or maintaining the appliance. [. . . ] · When vacuuming, certain carpets may generate small static charges in the clear bin . These are entirely harmless and are not associated with the mains supply. To minimise any effect from this, do not put your hand or insert any object into the clear bin unless you have first emptied it and rinsed it out with cold water.
TM TM
Ensure you register for your 5 year guarantee today
· Do not carry out any maintenance work other than that shown in this manual or advised by the Dyson Helpline and do not put anything into the openings or moving parts of the machine. · Only use parts produced or recommended by Dyson; failure to do so could invalidate your guarantee.
After registering for your 5 year guarantee, your Dyson vacuum cleaner will be covered for parts and labour for 5 years from the date of purchase, subject to the terms of the guarantee. If you have any query about your Dyson, call the Dyson Customer Helpline with your serial number and details of where/when you bought the cleaner. Your serial number can be found on your rating plate which is underneath the machine beneath the wheels or behind the clear binTM. Most queries can be solved over the phone by one of our trained Helpline staff. If your machine needs attention, we'll aim to send one of our Dyson engineers to fix it within 3 working days. We won't keep you waiting around either: our engineers can visit a home or work address - wherever is most convenient for you.
· Do not continue to use the cleaner if any part appears to be faulty, missing or damaged.
European conformity information: a sample of this product has been tested to conform with the following European Directives: 73/23/EEC Low Voltage (Safety) Directive, 93/68/ EEC CE Marking Directive and 89/336/EEC EMC Directive. NB: Small details may vary slightly.
This product is protected by the following Intellectual Property Rights:
CA 1, 241, 809 US 4, 573, 236 CA 2, 312, 827 US 6, 526, 623 CA 2, 313, 177 US 6, 691, 849 CA 2, 315, 078 US 6, 289, 553 CA 2, 325, 953 AU 2002231965 CA 2, 438, 855 EP 1361813 JP 2002-567126 US 2004-0068829 AU 287872 EP 1320317 JP 2004-509684 US 7069620 AU 2002226556 CA 2, 439, 250 EP 1370172 JP 4002185 US 6991666 AU 2002229966 CA 2, 439, 032 EP 1361812 JP 2004-537336 US 7278181 AU 2002226554 CA 2, 438, 077 EP 01370173 JP 2002-567131 US 6994740 AU 2002241151 CA 2442218 EP 1377196 JP 2004-528087 AU 2002225207 CA 2, 438, 069 EP 1361814 JP 3860541 US 7018439 AU 2002225232 CA 2, 438, 079 EP 1361815 JP 3940082 US 6974488
For your safety
230-240V 50Hz 1400 W
FOR PATENT INFORMATION SEE OPERATING MANUAL 02422-01-04
DYSON LIMITED MALMESBURY SN16 ORP ENGLAND UK
Do not pull on supply cable.
Do not use cleaner above you on stairs.
Do not use cleaner near naked flames.
Do not leave cleaner near heat sources.
US 6, 425, 931 US 6, 461, 508 CA 2, 351, 552 US 6, 572, 078 US 6, 442, 791 AU 2001232024 CA 2400404 EP 1265519 JP 2003-525673 US 7036183
Note your serial number for future reference:
Design registrations: CA 97332, US D475, 820, CA 86192 US D427, 737, US D455, 242
User Guide
Please read this guide carefully before using your DCO7
Do not place hands under brushbar when in use.
Do not use cleaner to pick up water or any other liquid.
Do not run over supply cable.
Do not use cleaner to pick up burning objects of any kind.
Equivalent patents, design registrations and applications exist in other countries.
JN. 15178 PN. 04482-12-01 23. 11. 07
15178_DCO7_UK_OPS_MAN_COV_v6
23/11/07
09:27
Page 2
DCO7
The ratchet noise warns that the brushbar is obstructed. Disconnect the machine from the electrical outlet before removing the obstruction.
Turn power off and unplug before checking for blockages.
1
Turn power off and unplug before changing/fitting the belt.
6
Mini turbine head*
1
Floortool*
2
4
Stair tool
Brush tool Crevice tool
*
Supplied with certain models only, or available as accessories.
2 3
Wand cap
5
7
2
1
Hose release On/off switch Cyclone release catch Bin emptying trigger Upper cable winder
B
Shroud release catch Shroud Wand
A
Airway inspection valve Valve release clips
Assembling DCO7
1 Slide hose into runners at back of machine, making sure tab clicks into place. Press wand release button and slide wand down into hose. DCO7 models without brush control are not suitable for hard floors, as the brushbar cannot be turned off. We recommend models with brush control for homes with mixed and hard flooring.
Changing/fitting your belt
(Models without brush control only)
Soleplate
U-bend airway inspection
Tilt machine forward and slide out U-bend airway inspection A. Make sure all parts have been replaced securely before using your machine.
Airway inspection valve
Squeeze valve release catches to remove airway inspection valve B. Check inside for blockages.
Brushbar
Lie cleaner on its front. [. . . ] Using the back of the cleaner as a lever, loop the belt around your thumb. Belt should be free of twists as shown.
6
Replace the brushbar and check end caps are securely in place. Rest the three tabs on the inside of the bumper strip, before pivoting soleplate into position and tighten fasteners.
2
7 5
Hose
2
3
Filter housing
Lower cable winder U-bend release clip Airway inspection (U-bend)
3
Replace soleplate and tighten fasteners. [. . . ]