Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual E-MU AUDITY 2000. We hope that this E-MU AUDITY 2000 user guide will be useful to you.
Lastmanuals help download the user guide E-MU AUDITY 2000.
You may also download the following manuals related to this product:
E-MU AUDITY 2000 2.0 SOFTWARE ADDENDUM (1476 ko)
Manual abstract: user guide E-MU AUDITY 2000
Detailed instructions for use are in the User's Guide.
[. . . ] Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
User Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Radio and Television Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The summing amp is located before the lag processor as shown in the following illustration.
Sum Node Lag 0
Lag
Lag 0 sum
Audity 2000 Operations Manual 77
Programming Basics Modulation Processors
Using the Modulation Processors
Modulation processors are inserted into a modulation routing as shown in the following diagram. The modular analog synthesizers of yesteryear were incredibly flexible, partly because processing devices could be connected in any order. Modulation processors are designed according to this modular concept. They can be linked and used in a wide variety of ways limited only by your imagination. Consider the following example:
Velocity ~
Cord
Switch
Cord
Switch On when Velocity > 0 Switch value is Scaled by Cord Amount
Pitch
The patch illustrated above is programmed by setting the PatchCord screens as shown below.
PATCHCORD Vel+- -> Switch
L1
#01 +100
PATCHCORD Switch -> Pitch
L1
#02 +022
This particular modulation shifts the overall pitch up a fifth when the key velocity exceeds 64. Velocities below 64 play at normal pitch. Velocities of 64 and above are raised a perfect fifth. The Velocity "~" source scales the played velocity around zero. In other words, low velocities (below 64) will have negative values and high velocities (64 and above) will be positive. The Switch module only outputs a "1" if the input value is greater than zero. This digital "1" value can be scaled through the attenuator on the PatchCord to raise or lower the pitch by any amount. In this case, a scaling value of +22 raises the pitch by a perfect fifth. The amount of the PatchCord on the input to the switch is unimportant because ANY velocity value equal or greater than 64 will flip the switch. If the input PatchCord amount were a negative value however, the action of the velocity would be reversed and velocities less than 64 would raise the pitch and velocities equal or greater than 64 would play the original pitch.
78 E-mu Systems, Inc.
Programming Basics Modulation Processors
But what if you want the velocity switch point to be something other than 64?Thanks to modulation processors, it can be done. Here's how.
Velocity ~
Cord
Switch
21 Cord
Switch On when Velocity > 0 Switch value is Scaled by Cord Amount
Pitch
DC
Cord
Connect the DC level to the input of the switch along with the velocity value. Note that more than one modulation source can be applied to the input of a processor. DC offset adds a fixed value based on the PatchCord Amount setting. If applied to the switch along with the velocity, it changes the velocity value required to trip the switch. By setting the DC amount to a negative amount, higher velocity values are required to trip the switch. Setting the DC value to a positive value would bring the velocity switch point down. The PatchCord screens for this patch are shown below.
PATCHCORD Vel+- -> Switch
L1
#01 +100
PATCHCORD DC -> Switch
L1
#02 -021
PATCHCORD Switch -> Pitch
L1
#03 +022
More Examples
To derive a smooth random function you could route the Pink Noise generator through one of the Lag Processors. [. . . ] You will be responsible for any damage or loss sustained during shipment in any direction.
E-mu Systems does not cover:
· Damages due to improper or inadequate maintenance, accident, abuse, misuse, alteration, unauthorized repairs, tampering, or failure to follow normal operating procedures as outlined in the owner's manual. · Deterioration or damage of the cabinet. · Damages occurring during any shipment of the product for any reason. · An E-mu product that has in any way been modified by anyone other than E-mu Systems, Inc.
186 E-mu Systems, Inc.
Credits
Limitation of Implied Warranties
This limited warranty is the sole and exclusive warranty provided by E-mu. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE E-MU AUDITY 2000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual E-MU AUDITY 2000 will begin.