Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EARLEX SPRAY PORT HV 7000. We hope that this EARLEX SPRAY PORT HV 7000 user guide will be useful to you.
Lastmanuals help download the user guide EARLEX SPRAY PORT HV 7000.
Manual abstract: user guide EARLEX SPRAY PORT HV 7000
Detailed instructions for use are in the User's Guide.
[. . . ] N0151 07_05. qxd
16/01/2006
10:49
Page 1
HV7000
OPERATING INSTRUCTIONS Thank you for purchasing the Earlex Spray Port. This is a highly versatile spray kit and can be used on a variety of applications. BEFORE USE - PLEASE READ THE SAFETY & OPERATING INSTRUCTIONS. Please retain for future reference
N0151 07_05. qxd
16/01/2006
10:49
Page 2
SAFETY INSTRUCTIONS
WARNING! [. . . ] (See exploded view on page 8 to show the fitting detail for the different spray applicator types. ) Unwind the hose from the Carrier Stand & screw the motor end of the hose to the outlet port at the front of the turbine unit. Connect the spray applicator end of the hose to the spray applicator using the quick release connector. Uncoil the power cord and plug it in to a suitable power outlet. ALWAYS KEEP THE MOTOR UNIT AS FAR AWAY FROM THE SPRAYING AREA AS POSSIBLE TO PREVENT PAINT CONTAMINATING THE MOTOR. Once you have set up ready to spray, switch on the unit. No paint will be sprayed until the trigger on the spray applicator is gently pulled. Before starting any work on spraying actual objects we suggest you spend some time practicing on cardboard or newspaper until you have got used to how the spray applicator works. SETTING UP YOUR SPRAY APPLICATOR Choose the best Needle & Fluid Tip for your application. Your Spray Port is supplied to you with a 2. 0mm diameter Needle & Fluid Tip. This is a good size for most applications. However, there are other sets available to cater for a wider range of materials that you may want to spray. In general, the larger the diameter of the Needle & Fluid Tip, the more suitable it is for higher viscosity materials. The larger diameters also allow a greater volume of material to be applied. The smaller diameters are more suitable for low viscosity materials & lighter application. For the Spray Port type "P", Needle & Fluid Tip sets are available at 1. 0mm and 1. 5mm diameter. For the Spray Port type "A", Needle & Fluid Tip sets are available at 1. 0mm, 1. 5mm and 2. 5mm diameter. NEEDLE SELECTION GUIDELINES Needle/Fluid Tip Size Material 1. 0mm/1. 5mm Acrylics, Synthetics, Polyurethane, Lacquers, Fluorescents, Wood Stains Oil base, Hammers, Oxides, Primers, Air Drying, Enamels, Varnish, Marine Paint, Multi-Colour, Industrial Synthetics, Latex Oils, Polyurethane, Aluminium Emulsions, Chlorinated rubber, Oxides, Zinc Rich Primers, Epoxy Plastic Adhesives, Polyurethane, Floor Paving Paints 4
1. 5mm/2. 0mm
2. 0mm/2. 5mm
N0151 07_05. qxd
16/01/2006
10:49
Page 5
SPRAY PATTERNS
Fig. 4
The spray applicator has 3 different spray patterns Horizontal, Vertical and Round (Fig. 4) The horizontal and vertical are recommended for large surfaces. Vertical Jet Horizontal Jet Round Jet The round spray is used for small objects or for areas - such as corners that are difficult to reach. To adjust the spray pattern, loosen the Air Cap Ring (1), adjust the position of the Air Cap (2) to obtain either a vertical, horizontal or round pattern then re-tighten the aircap ring. PAINT VOLUME Fig. 5(a) shows the Air Volume Control Valve which regulates the flow of air to the gun. When the Valve is fully open you will achieve maximum coverage. To achieve this rotate `fully' anti-clockwise. [. . . ] The turbine unit can only be fully serviced by authorised service agents.
7
N0151 07_05. qxd
16/01/2006
10:49
Page 8
SPRAY APPLICATOR SPARE PARTS DRAWINGS
TYPE P
14 7 6 8
9 5 10 4 3 2 1
Key Description No. Viscosity Cup
Part L0215 L0238 L0206 L0237 L0211 L0236 L0216 L0210 L0208 L0272 L0214 L0212 L0240 N0182 SG243
15
11
Optional Extras: Nozzles & Fluid Tips of different sizes can be obtained as sets under the following accessory numbers. Please call our helpline to order these on +44 (0) 1483 454666. 1. 0mm dia Fluid Tip, Needle & seal HVACC10R 1. 5mm dia Fluid Tip, Needle & seal HVACC15R 2. 0mm dia Fluid Tip, Needle & seal HVACC20R
12
13
TYPE A
10 11 12
9 4 5 6 7 8
1
2
3
7 13
17 14 18 16 26 19 20 21 22 27 23 24 25 15
Key Description 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EARLEX SPRAY PORT HV 7000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EARLEX SPRAY PORT HV 7000 will begin.