User manual EATON ELLIPSE ECO 1200 USB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EATON ELLIPSE ECO 1200 USB. We hope that this EATON ELLIPSE ECO 1200 USB user guide will be useful to you.

Lastmanuals help download the user guide EATON ELLIPSE ECO 1200 USB.


Mode d'emploi EATON ELLIPSE ECO 1200 USB
Download
Manual abstract: user guide EATON ELLIPSE ECO 1200 USB

Detailed instructions for use are in the User's Guide.

[. . . ] Indd 5 10/12/2010 11:15:08 Operating conditions product is an Uninterruptible Power Supply (UPS) for computers and their peripherals, television sets, stereo systems and video recorders. It must not be used to supply other electrical equipment (lighting, heating, household appliances, etc. L This English automatically deactivated and the peripherals shut down. This function (deactivated by default) is validated and configured using the configuration tool integrated in the software. [. . . ] L Battery backup outlets 9 : Equipment connected to these outlets is supplied as soon as button 12 turns green (see figure E). These outlets can be turned on even if the UPS is not connected to AC power (button 12 flashes). L AC-power disturbance: If AC power is disturbed or fails, the UPS continues to operate on battery power. In normal mode, the audio alarm beeps every ten seconds, then every three seconds when the end of battery backup time is near. In silent mode (see the section on settings), the audio alarm simply beeps once when the UPS transfers to battery power. L If the power outage lasts longer than the battery backup time, the UPS shuts down and automatically restarts when power is restored. Following a complete discharge, a few hours are required to recharge the battery back to full backup time. L To save battery power, it is possible to press button 12 to cut the supply of power to the devices connected to the battery backup outlets. L Lightning protection: All outlets, whether backed up or simply filtered, include surge protection, whatever the position of button 12 . L Shutdown of the battery backup outlets 9 : Press button 12 for more than two seconds. Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals (scanner, printer) in standby mode, the Ellipse ECO is equipped with EcoControl outlets that are dependent on the Master outlet. When the main application supplied by the Master outlet (computer) is shut down, the EcoControl outlets are 6 Ellipse 500 / 650 / 800 Ellipse 1200 / 1600 8 12 10 11 9 8 13 9 13 614-06803-00 614-06803-00. indd 6 10/12/2010 11:15:08 support. ) 1 2 3 Troubleshooting (For further information, visit the www. Com site or contact after-sales Problem l Diagnostic Solution Press button 12 and check that it turns green. L Connect the devices to the battery backup outlets 9 . L Disconnect excess equipment and reset the circuit breaker 13 by pressing the corresponding button. L 4 5 6 The battery backup outlets 9 are l Button 12 is not lighted on. L The connected devices are not l The devices are not connected to supplied when AC power fails. L AC power is available, but the l Circuit breaker 13 , located under UPS operates on battery power. The UPS, has been tripped by an overload on the UPS output. l The filtered outlets 8 are not l Circuit breaker 13 , located under supplied. [. . . ] L Accessing the programming mode: with the device switched off, press button 12 for 11 s and release it when the audio alarm sounds. L Display the programming mode: with the device switched off, press button 12 for 6 s and release it once LEDs 10 11 have come on. Of the 3 possible voltage ranges according to the status of LEDs 10 and 11 : Normal mode (factory configuration): AC supply between 184V and 264V Low range mode: AC supply between 161V and 264V Low and high range mode: AC supply between 161V and 284V l Display l Accessing of the 2 possible audio alarm modes: Normal mode (factory configuration): the UPS emits a beep every 10 s when operating on its battery. Silent mode: the UPS emits a single beep when switching to battery operation and then remains silent. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EATON ELLIPSE ECO 1200 USB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EATON ELLIPSE ECO 1200 USB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag