User manual EBODE IR LINK C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EBODE IR LINK C. We hope that this EBODE IR LINK C user guide will be useful to you.

Lastmanuals help download the user guide EBODE IR LINK C.


Mode d'emploi EBODE IR LINK C
Download

You may also download the following manuals related to this product:

   EBODE IR LINK C PRODUCTSHEET (907 ko)

Manual abstract: user guide EBODE IR LINK C

Detailed instructions for use are in the User's Guide.

[. . . ] SAFETY WARNINGS • To prevent short circuits, this product (except if specified for outdoor usage) should only be used inside and only in dry spaces. Do not expose the components to rain or humidity. € Avoid strong mechanical tear and wear, extreme ambient temperatures, strong vibrations and atmospheric humidity. [. . . ] This allows them to be “stuck” to the IR sensor “window” on your source equipment. This plugs into a 230V~50Hz outlet to provide power to the IRLP Receiver. The ebode IR Link C system uses the coaxial cable that carries the TV RF signal from the source equipment in the main room to the remote room, to send the IR control signals back to the source equipment. The coaxial cable may be up to 300m in length. If you already have a coaxial cable connecting your video 10-8-2010 4 ebode IR LINK C equipment with a remote room, your current hook-up should be similar to figure 1. If it isn't, run a single length of RG59 or preferably RG6 cable from the Main Room to the Remote Room. NOTE: If RF amplifier(s), splitters or taps are used anywhere in the line of the coaxial cable between the CPL Coupler and the INJ Injector, you must verify if those are DC passive in order to be sure to route the IR commands through the amplifier(s) and splitters. Installing the ebode IR Link C INSTALLING THE IRLP IR RECEIVER Insert the red mini plug attached to the IRLP into the jack marked "IR RECEIVER" on the INJ Injector. Plug the 12VDC Power Supply cord into the jack marked "+12 V" on the INJ Injector. Plug the power supply into a 230V~50Hz outlet after you have made all other connections. Position the IRLP IR Receiver so that the InfraRed beam from the handheld remote control has a direct view at the front of the unit (within 10m). The Receiver can be fixed to the surface by using the double side tape pad or via a slide on screw hole on the bottom of the unit. INSTALLING THE INJ INJECTOR Insert the "TO TV" plug on the back of the INJ Injector into "RF IN" on the TV in the Remote Room. Connect the room-to-room cable to "ANT INPUT" on the INJ Injector. INSTALLING THE CPL COUPLER Insert the "SAT/VCR" plug on the back of the CPL Coupler into "OUT TO TV" on DVR in the main room. Connect the room-to-room cable to "REMOTE/TV" on the CPL Coupler, as shown in Fig. 2 INSTALLING THE 3IREDB TRIPLE IR EMITTER Plug the 3IREDB Emitter into the jack marked "EMITTER" on the CPL Coupler in the main room. The emitters should be installed directly to the InfraRed sensor "window" on the front panel of the satellite Receiver, DVR, cable box, etc. [. . . ] Anslut rum till rum kabeln till “REMOTE/TV” på INJ CPL kopplingen, som visas i fig. 1mm Cavo diodo Emettitore IR: 3 LED IR Lunghezza cavo: 3 m totale da CPL a LED IR Ricevitore: dimensioni 55x40x25mm 10-8-2010 34 ebode IR LINK C DECLARATION OF CONFORMITY Hereby, ebode electronics, declares that this ebode IR Link C is in compliance with the essential requirements and other relevant provisions of the following Directives: Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Directive 2005/32/EC of the European Parliament and of the Council of 6 July 2005 establishing a framework for the setting of eco design requirements for energy-using Technical data and copies of the original Declaration of Conformity are available and can be obtained from ebode electronics: PB 25, NL-4264ZG, the Netherlands. User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) This document contains important information for users with regards to the proper disposal and recycling of ebode products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EBODE IR LINK C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EBODE IR LINK C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag