[. . . ] ValveMateTM 7000 Controller Operating Manual
Steady Test Time Set Clear Fast Slow POWER RUN SETUP CYCLE
®
A NORDSON COMPANY
VALVEMATE 7000
Run Setup
Purge Program
Fast Slow Time Set
Pressure Time
STOP
Electronic pdf files of EFD® manuals are also available at www. efd-inc. com/manuals. html
A NORDSON COMPANY
USA: 800-556-3484 or +1-401-434-1680 Europe: 0800 585733 or +44 (0) 1582 666334 Asia: +86 (21) 5854 2345 technical@efd-inc. com www. efd-inc. com
EFD ONE YEAR LIMITED WARRANTY
All components of the EFD ValveMate 7000 are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions. EFD will repair or replace free of charge any part of the equipment thus found to be defective, on authorized return of the part prepaid to our factory during the warranty period. In no event shall any liability or obligation of EFD arising from this warranty exceed the purchase price of the equipment. This warranty is valid only when oil-free, clean, dry, filtered air is used. [. . . ] The bracket can be mounted either over or under the cabinet and will allow the 7000 to pivot up or down 30 degrees from a horizontal position. The bracket may be permanently mounted, or attach the rubber feet included and use the bracket as a bench-top tilt stand. Four rubber feet on the console are provided if the bracket is not used. For panel mounting, a panel mount bracket kit is available (order #7000PMK).
Input Power
Check the input power cord receptacle fuse cartridge to ensure that the voltage is set properly. The cartridge may be set for input voltages of 100, 120, or 220 VAC. To change voltage, remove the fuse cartridge. Remove the fuse holder from the cartridge, rotate the holder and position the correct voltage to show through the cartridge window. Replace the cartridge into the power cord receptacle and ensure that both sides snap securely into position. Install the power cord.
Spare fuse
Voltage value Cartridge window (check voltage indicated)
8 / Setup
10
0
120
22
0
Fuse T 125mA 250V 100/120/220VAC 50/60Hz 10/9VA Foot Pedal Air Input
220
Air Output
Exhaust
1 2 3 4 5 6 7 8
1. Contact Closure
Initiate Connection
The 7000 can be initiated through a time cycle by the application of 5 to 24 VDC to terminals 1 and 2, by closure of mechanical contacts across terminals 7 and 8, or by using an optional EFD foot pedal (order #2015A), plugged into the foot pedal receptacle. A connection schematic is detailed on page 15. Select one of these methods and install now.
connect one end to the #1116 air tee. Connect the other end of the air line by pushing it firmly into the air input connector on the ValveMate 7000 until it bottoms out. Be sure that the line is inserted all the way into the fitting. Set the pressure at the #2000F755 filter regulator to 70 psi (4. 8 bar). The quick-connect on the air tee is used to provide air pressure to the air pressure regulator on EFD fluid reservoirs. This connection will be made at a later step in the setup.
Air Input Connection
Connect the ValveMate 7000 to plant air by first installing the EFD five-micron filter regulator (#2000F755) to your air supply. Install the air tee with barb fitting (#1116) in the output of the filter regulator. 10 feet of 1/4" OD air line is supplied. Simply push in and twist to the right to lock. Pressure to the 7000 should be set at 70 psi (4. 8 bar). Remember, pressure may be checked by pressing the PRESSURE / TIME button. [. . . ] Voltage Initiate Circuit 5 to 24 VDC Power Source Power Consumption 2. 2mA at 5 VDC 15. 0mA at 24 VDC 2. End-of-Cycle Feedback Circuit 5 to 24 VDC Power Source Maximum Load 250mA A relay and a lamp are illustrated as examples for utilizing the feedback and alarm circuits.
+ _
+
Fuse Opto Coupler Nonvolatile Memory Fuse Opto Coupler Pressure Sensor Power Supply 100/120/ 220 VAC 50/60 Hz 10/9VA +5 VDC
8 5 6 3 4
_
Solenoid Valve
Lamp 7
3. Low Pressure Alarm Circuit 5 to 24 VDC Power Source Maximum Load 250mA
+12 VDC
Protector
4. Mechanical Contact Initiate Mechanical Contact Power Consumption Contact Load = 5. 5 VDC / 100uA NOTE: DO NOT APPLY VOLTAGE
15 / Input/Output Connections
Connecting More than One 7000
Follow these instructions and diagrams when the Voltage Initiate or End-ofCycle Feedback features are used in a multiple 7000 installation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD 7000
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.