[. . . ] A S S E M B LY
I N S T RU C T I O N S GB
Mod.
FUSION
advanced mobular stair system
MC
Code
MD. K. 100
Rev
02
Edition 06/2008
advanced mobular stair system
- FUSION -
CONTENTS
PART 1 Wooden components. Components PART 2 configuration Useful height measurement Using the rule Tracing Calculating the number of steps Page 2 " " 2 3 Preparing and drilling the steps Assembling the steps Assembling the final step PART 3 Preparing the columns Assembling the columns Assembling the handrail Assembling the baluster handrail Completion and checks Page 8 " " 9 10
Page 5 " " " ". " 5 6 6 7 8
Page 15 " " " " " 15 16 20 22 23
PART 1
WOODEN COMPONENTS
Before proceeding to the various assembly stages, empty the cardboard package and arrange all parts on a flat surface to check that all components included in the list attached are present, and that no damaged parts are present. pcs
L11
12
L15
1
L12
1
B16
2
L13
1
D1
1
L14
9
K82
1
-2-
Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. [. . . ] In this case, we suggest to group together those of the same size starting from above.
K50
K45
K50 K45 L11 K45
K44
K49
Fig. 8
"A" 225 "A" 220 "A" 215 "A" 210
"A" 230
"A" 235
K50
K50
K50
K50
K50
K50
Fig. 9
FUSION
Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 www. ehleva. com ehleva@ehleva. it By Mobirolo S. p. A.
-9-
advanced mobular stair system
- FUSION -
ASSEMBLING THE FINAL STEP
After completing the operation and all steps, washers and spacers have been mounted and inserted into the pile, the L12 final step must be prepared. The first operation to be carried out consists in shaping the step according to the opening/hole, which may either be round or rectangular.
K51
L12
K5 K50
Fig. 10
To cut precisely, insert the L12 step into the K5 screw as shown in fig. To place the final step correctly, use the K51 washer to centre it. (Fig. 10) Trace the border of the hole by using the opening as a reference. It is strictly forbidden to climb up and use the staircase before having completed the "Mounting the columns as anchoring the final step" stage.
Fig. 10a
Cut the step by following the marks obtained previously by means of an alternative electric saw or any other cutting tool. (Fig. 11) Trim by eliminating any scraps or chips.
Fig. 11
- 10 -
Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 www. ehleva. com ehleva@ehleva. it By Mobirolo S. p. A.
FUSION
advanced mobular stair system
- FUSION -
The final step included in the package has four Ø11 holes to mount the columns. To assemble the FUSION model, three additional Ø11 holes must be drilled between those already present. Measure the distance between holes and mark the intermediate point where the additional holes must be drilled as shown in fig. 12. While drilling, make sure to place the step on a soft surface, preferably wood, so as to avoid damaging the drill at the end of the operation and obtain a hole free from scraps and chips.
Ø11
Fig. 12
After having moved the final step in the desired position, trace the points to be drilled to anchor the bracket. In the bottom side of the step, identify the most suitable position to anchor the bracket, which should not interfere with the holes to mount the columns. Trace the point to be drilled as shown in fig. 13
FUSION
Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 www. ehleva. com ehleva@ehleva. it By Mobirolo S. p. A.
- 11 -
advanced mobular stair system
- FUSION -
Temporarily disassemble the
final step to drill the points marked previously as shown in fig. 14 - 14a.
K58
25 mm
Ø13 Ø13
Ø12
25 mm
Fig. [. . . ] To join the sectors, proceed as follows: on the L14 sector to be joined to a previously mounted sector, mount the K71 washer and the K72 element into the end without connection and lock through a K73 screw by tightening fully. Mount the unit obtained by inserting it into the end with connection of the sector already assembled to the columns. The end with the connection has a Ø5 hole. Insert the K74 dowel into the hole and lock; check it faces downwards. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EHLEVA FUSION
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.