User manual EHLEVA VECTOR 83

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EHLEVA VECTOR 83. We hope that this EHLEVA VECTOR 83 user guide will be useful to you.

Lastmanuals help download the user guide EHLEVA VECTOR 83.


Mode d'emploi EHLEVA VECTOR 83
Download
Manual abstract: user guide EHLEVA VECTOR 83

Detailed instructions for use are in the User's Guide.

[. . . ] Mod. VECTOR 70 VECTOR 80 advanced mobular stair system MC Code MD. K. 001 Rev 01 Edition 04. 2008 - VECTOR 70 - VECTOR 80 advanced mobular stair system CONTENTS Structure of the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Wooden components VECTOR 70 - VECTOR 80. " Components VECTOR 70 - VECTOR 80. [. . . ] 80 L=740 L=840 X 1340-1430 1500-1590 Y 2040-2130 2300-2390 Z 750 850 L=740 L=840 X 1140-1200 1280-1340 Y 2040-2130 2300-2390 Z 980 1100 L=740 L=840 X 940-970 1060-1090 Y 2040-2130 2300-2390 Z 1180-1210 1320-1350 VEC. 80 L=740 L=840 X 740 840 Y 2040-2130 2300-2390 Z 1380-1440 1540-1600 L=740 L=840 X 1140-1200 1280-1340 Y 2240-2360 2520-2640 Z 750 850 L=740 L=840 X 940-970 1060-1090 Y 2240-2360 2520-2640 Z 980 1100 VEC. 80 L=740 L=840 X 740 840 Y 2240-2360 2520-2640 Z 1180-1210 1320-1350 L=740 L=840 X 740 840 Y 2440-2590 2740-2890 Z 980 1100 L=740 L=840 X 940-970 1060-1090 Y 2440-2590 2740-2890 Z 750 1100 VECTOR 70 = VEC. 80 L=740 L=840 X 740 840 Y 2640-2820 2960-3140 Z 750 850 VECTOR 70 - VECTOR 80 Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 ehleva@ehleva. it By Mobirolo S. p. A. - 15 - - VECTOR 70 - VECTOR 80 advanced mobular stair system TRAKING After having identified and set the parameters identifying the staircase characteristics (H height, P tread and A rise) assembly operations can actually start. On the arrival floor slab, the correct position must be identified to anchor the step support. Position the D03 template on the floor slab, make sure it is aligned with the floor (use a level) and comply with the following references: value V = 260mm min. for the VECTOR 70 model (side without banister) 310mm min. for the VECTOR 80 model (side without banister) value A = corresponding to the value of the "A" rise calculated previously. To anchor the module, two holes are enough. Identify the holes that need to be reproduced: in general refer to those halfway the floor slab width, not too close to the floor surface. 3 1 50 m m Ø1 6 Fig. 5 - 16 - Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 ehleva@ehleva. it By Mobirolo S. p. A. VECTOR 70 - VECTOR 80 - VECTOR 70 - VECTOR 80 advanced mobular stair system PREPARING COLUMNS AND STEPS Before proceeding to assemble the steps, mount the P107 banister column support fig. Drill a Ø4 hole by means of a wood drill in the points identified on the step and achieve a 30 mm depth as shown in fig. Be very careful when operating on the bottom side of the step, where anchoring holes are already present, and on the correct side where the banister will be mounted. Fig. 6 1 st K66 2nd K80 P107 Fig. 6 VECTOR 70 - VECTOR 80 Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 ehleva@ehleva. it By Mobirolo S. p. A. Fig. 9 - VECTOR 70 - VECTOR 80 advanced mobular stair system ASSEMBLING THE STEP L20 B205 P107 Fig. 11 At this point form the P106 - P106a spacer package which will determine the size of the rise set previously. To define the number of spacers to be used, refer to the "table A" attached to the pages 9-10-11. [. . . ] All configurations envisage that an additional column must be mounted on the last straight step before the staircase turns. Figure 41 shows the example of a "U" staircase. L15 B301 K71 L15 K77 L15 m m /50 40 L15 K80 Ø3 K65 Fig. 40 Via C. Colombo, 22/A - 42046 - Reggiolo - Reggio Emilia - Italy Tel. +39 - 0522-97 32 34 - Fax +39 - 0522-97 31 39 ehleva@ehleva. it By Mobirolo S. p. A. VECTOR 70 - VECTOR 80 - 29 - - VECTOR 70 - VECTOR 80 advanced mobular stair system After having assembled the handrail the K68 plug must be mounted at both ends. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EHLEVA VECTOR 83

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EHLEVA VECTOR 83 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag