User manual EINHELL RG-AW 1139

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EINHELL RG-AW 1139. We hope that this EINHELL RG-AW 1139 user guide will be useful to you.

Lastmanuals help download the user guide EINHELL RG-AW 1139.


Mode d'emploi EINHELL RG-AW 1139
Download
Manual abstract: user guide EINHELL RG-AW 1139

Detailed instructions for use are in the User's Guide.

[. . . ] Consequential damage caused by flooded rooms in the event of the pump suffering faults must be prevented by the user by means of suitable measures (for example installing alarm systems or a reserve pump, etc. In the event of a failure, repair work may only be carried out by an electrician or by ISC after sales service personnel. This equipment is not designed to be used by people (including children) with limited physical, sensory or mental capacities or those with no experience and/or knowledge unless they are supervised by a person who is responsible for their safety or they have received instructions from such a person in how to use the equipment safely. Children must always be supervised in order to ensure that they do not play with the equipment. [. . . ] Green and red are lit: The pump is running dry without transport fluid. The flow switch will attempt to rectify the dry running three times before the dry running guard finally trips. Green is lit, red is flashing: The dry running guard has tripped, it is no longer possible to draw in the transport fluid. Find the cause of the fault using the pump's operating manual (for example leaking intake line) and rectify it. Switch off the pump and pull the pump's mains plug. remove the existing output line on the actual pump. Ensure that you bleed the pump correctly (refer to the pump's manual for further details). 2 / Item 5) to the connection adapter and secure it to the connection adapter using the union nut (Fig. The flow switch must be in an upright position, in other words the connector for the pump (Fig. 2 / Item 5) must be at the bottom and the connector for the output line (Fig. If it is in any other position, the flow switch cannot work correctly. 5) and carefully fill the flow switch with the transport fluid up to the bottom end of the thread on the pressure connector (Fig. 2 / Item 6) to prevent the system running dry. Now screw the output line to the connector provided for it (Fig. 2 / Item 6) on the flow switch and ensure that you seal the connection properly, for example with Teflon tape (not supplied). After checking all the connections and lines, connect a consumer to the output line and open it so that any air in the output line can escape when the transport process is started. 1 / Item 3) on the flow switch to an adequately fused (at least 10 A) 230V ~ 50Hz safety mains socket with a ground contact. Switch on the pump if it is fitted with a switch, otherwise the pump will now start automatically and will start to transport the medium. The consumer can be closed as soon as the transport fluid is emitted from it. The flow switch will now switch off the socket (Fig. If you place it into storage, ensure that the flow switch does not contain any transport fluid so as to avoid frost damage. If the power cable for this equipment is damaged, it must be replaced by the manufacturer or its aftersales service or similarly trained personnel to avoid danger. [. . . ] In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies when an on-site service is used. In order to assert your guarantee claim, please send your defective device postage-free to the address shown below. Please enclose either the original or a copy of your sales receipt or another dated proof of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EINHELL RG-AW 1139

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EINHELL RG-AW 1139 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag