[. . . ] English
User's Manual
FlexScan T550
Color Display Monitor
®
CONTENTS
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Controls & Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If a problem occurs when using a non-interlaced signal, try adjusting the graphics board to increase the refresh rate (if possible). Refer to the graphics board manual for information.
Flicker The term "flicker" refers to noticeable shimmering that occurs when the image on the screen is redrawn ("refreshed") too slowly. A refresh rate of 80 Hz means the image is redrawn 80 times per second. Most people will notice flicker at image refresh rates as high as 60 or 70 Hz, whereas refresh rates of 72 Hz or above usually is not noticeable. Flicker is known to be the cause of visual fatigue.
16
3
TROUBLESHOOTING
Problems
10)· The entire screen appears bluish or reddish. (red, green, blue)
Points to check with possible solutions
The CRT is not warmed up. Allow 30 minutes for the monitor to stabilize.
E
Explanation of the Characteristics of CRTs When the monitor is not fully warmed up, the screen may look slightly colored, e. g. This phenomenon is due to the unstableness of the electron gun during its warm-up period. Please wait for about 30 minutes until the monitor stabilizes in order to gain its proper color. 11)· Control Pad "ENTER key" does not operate. · AUTO-SIZING button does not operate. 12)AUTO-SIZING button does not work properly. To unlock: switch off the monitor power, then hold down the AUTOSIZING button and switch the monitor back on. The AUTO-SIZING function is intended for use on the Macintosh and on IBM compatibles running Windows. It may not work properly if either of the following applies. - You are running an AT-compatible PC on MS-DOS (not Windows). - The background color for the "wallpaper" or "desktop" pattern is set to black. Some signals from graphics boards may not function properly. red, green, blue) may appear for an instant while performing the AUTO-SIZING function, althought, this phenomenon is not a failure.
3
TROUBLESHOOTING
17
Problems
13)Two horizontal hairlines are visible on the screen.
Points to check with possible solutions
These are dampening wires. Dampening wires are used to support the CRT's aperture grille, and are visible as thin dark lines across the screen. All EIZO aperturegrille type CRTs include two such horizontal wires. The aperture grille itself is a grid of taut metal filaments that spans the entire screen from top to bottom.
14)Faint black vertical lines are visible on the screen.
The aperture grille may be misaligned. [. . . ] increased risks of skin cancer (malignant melanoma) as a consequence.
Lead**
Lead can be found in picture tubes, display screens, solders and capacitors. Lead damages the nervous system and in higher doses, causes lead poisoning. The relevant TCO'99 requirement permits the inclusion of lead since no replacement has yet been developed.
For Europe, etc. (220-240 Vac) Only
CE Marking
Declaration of Conformity
Kind of equipment/Type-designation: is in compliance with: Council Directive 73/23/EEC Council Directive 89/336/EEC
Monitor/T550
EN60950:1992+A1+A2+A3+A4+A11 EN55022 (classB):1997 EN50082-1:1992 EN61000-3-2:1995 EN61000-3-3:1995
Konformitätserklärung
Geräteart/Gerätetyp : Monitor/T550
den folgenden Normen oder Vorschriften entspricht: EU-Richtlinie 73/23/EEC EU-Richtlinie 89/336/EEC
EN60950:1992+A1+A2+A3+A4+A11 EN55022 (classB):1997 EN50082-1:1992 EN61000-3-2:1995 EN61000-3-3:1995
Déclaration de conformité
Nature de l'équipement/Type-désignation : Moniteur/T550 est en conformité avec : Directive Européenne 73/23/EEC Directive Européenne 89/336/EEC EN60950:1992+A1+A2+A3+A4+A11 EN55022 (classB):1997 EN50082-1:1992 EN61000-3-2:1995 EN61000-3-3:1995
Hinweis zur Ergonomie :
Dieser Monitor erfüllt die Anforderungen an die Ergonomie nach ZH1/618/10. 80 durch die Ansteuerung mit der VGA - Videokarte, 1024 Punkte x 768 Zeilen, RGB analog, 0, 7 Vp-p und mindestens 85, 0 Hz Bildwiederholfrequenz, (non interlaced). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE EIZO FLEXSCAN T550
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.