Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE DMS-1183-64. We hope that this ELECTRO-VOICE DMS-1183-64 user guide will be useful to you.
Lastmanuals help download the user guide ELECTRO-VOICE DMS-1183-64.
Manual abstract: user guide ELECTRO-VOICE DMS-1183-64DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Das robuste Stahlblech-Chassis ist besonders verwindungssteif und speziell auf die Belastungen des harten Tourbetriebs ausgelegt. Die thermische Stabilität wird durch zwei 3-Stufen Lüfter (off/slow/fast) mit sehr niedrigem Geräuschpegel gewährleistet. Die Front-to-Rear Luftführung, erlaubt den Betrieb auch in großen und schmalen Endstufen-Racks. Die Eingänge sind elektronisch symmetrisch auf XLR-Buchsen geführt. [. . . ] Auf der Frontblende sitzen die in dB skalierten Levelregler, die als besonders präzise, bediensichere Rastpotis ausgeführt und zum Schutz vor mechanischer Beschädigung in der Frontblende versenkt sind. Die CP-Serie bietet intern die Möglichkeit zur Nachrüstung einer analogen Signalprozessorkarte mit Frequenzweichen- und Filterfunktionen. Eine schnelle Übersicht über den aktuellen Betriebszustand der Endstufen vermittelt das leicht ablesbare LED-Display. Die Leistungsausgänge CHANNEL A, CHANNEL B und BRIDGED OUT sind als extrem zuverlässige SPEAKON-Buchsen ausgeführt. Ebenfalls auf der Rückwand befinden sich ein Groundlift-Schalter, der bei Bedarf das Gehäuse der Endstufe von der Schaltungsmasse trennt und somit Brummschleifen verhindern hilft. Alle CP- Endstufen können im Normalbetrieb an Lasten bis hinab zu 2 Ohm und im Brückenbetrieb bis zu minimal 4 Ohm eingesetzt werden.
DESCRIPTION
The audio performance of CP power amps are simply extraordinary. Optimised power supply units employing low-leakage toroidal transformers and the consistent use of Class-H technology provide extensive headroom far above the stated nominal output. At the same time this contributes to a reduction in weight and power dissipation. The CP-Series is designed in Class-H technology, i. e. the power amp provides extremely fast, signal-dependent operating voltage switching, which results in doubling the regular supply voltage when needed. Compared to Class-AB power amps, Class-H power amps generate by far less power dissipation at identical output. In normal operation, all CP-Series power amps are capable of driving loads as low as 2ohms. In Mono-Bridged mode the allowable minimum load is 4ohms.
SPECIFICATIONS
- Amplifier at rated conditions, both channels driven, 8 loads, unless otherwise specified. CP 1800 Load Impedance Maximum Midband Output Power
THD = 1%, 1kHz, Dual Channel
2 900W -1450W 1200W --
4 600W 500W 850W 720W 1800W 62V 10Hz . . . 60kHz 32, 0 dB +3. 2 dBu (1. 12 Vrms) < 0. 05% < 0. 02% < 0. 01% +22dBu (9. 76 Vrms) <- 80dB 15Hz . . . 40kHz (+/- 1dB) > 300 30 V/ms 105. 5dB Class H
8 350W 250W 450W 410W 1200W
Rated Output Power
THD < 0. 1%, 20Hz . . . Single Channel Output Power
IHF-A
Max. Single Channel Output Power
Continuous, 1kHz, THD-1%
Max. Bridged Output Power
THD = 1%, 1kHz
Maximum RMS Voltage Swing
THD = 1%, 1kHz
Power Bandwith
THD = 1%, ref. 1kHz, half power @ 4
Voltage Gain
ref. 1kHz
Input Sensitivity
at rated output power
THD at rated output power,
MBW = 80kHz, 1kHz
IMD-SMPTE
60Hz, 7kHz
DIM30
3. 15kHz, 15kHz
Maximum Input Level Crosstalk
ref. 1kHz, at rated output power
Frequency Response
ref. [. . . ] 60 Hz (factory configured) 500W Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turn-on delay Front-to rear, 3stage-fans I 483 x 88, 1 x 386, 8 15 kg (33 Ibs) Rear-rackmount 15, 5" (NRS 90262) 112930 Rear-rackmount 18" (NRS 90264) 112933
Protection Cooling Safety Class Dimensions
(W x H x D), mm
Weight Optional
- Depending on the ambient temperature, the unit might not operate continuously at 2 ohms load in Dual Mode or 4 ohms load in Bridged Mode.
SPECIFICATIONS
- Amplifier at rated conditions, both channels driven, 8 loads, unless otherwise specified. CP 2200 Load Impedance Maximum Midband Output Power
THD = 1%, 1kHz, Dual Channel
2 1100W -2200W 1500W --
4 800W 700W 1200W 950W 2200W 72V 10Hz . . . 60kHz 32, 0 dB +4. 7 dBu (1. 33V rms) < 0. 05% < 0. 02% < 0. 01% +22dBu (9. 76 Vrms) <- 80dB 15Hz . . . 40kHz > 300 35 V/ms 107dB Class H
8 500W 350W 625W 550W 1600W
Rated Output Power
THD < 0. 1%, 20Hz . . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE DMS-1183-64
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE DMS-1183-64 will begin.