User manual ELECTRO-VOICE XI SYSTEM APPLICATIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE XI SYSTEM APPLICATIONS. We hope that this ELECTRO-VOICE XI SYSTEM APPLICATIONS user guide will be useful to you.

Lastmanuals help download the user guide ELECTRO-VOICE XI SYSTEM APPLICATIONS.


Mode d'emploi ELECTRO-VOICE XI SYSTEM APPLICATIONS
Download
Manual abstract: user guide ELECTRO-VOICE XI SYSTEM APPLICATIONS

Detailed instructions for use are in the User's Guide.

[. . . ] power: 2 x 120°-150°, *2 x 150° 20-30 meters, *20-25 meters 3, 000 Watts cont. * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left In 2 Out 1 Main Right Lo L Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #37 (1152/64), #39(1152/94) Comments Options For medium SPL's as stand alone. In higher SPL applications as supplement. P2000 may be used through out (deduct ~3 dB on HF input level). [. . . ] power: 4 x 100° 20 meters 9, 800 Watts (cont. ) * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left #2 Sub Comments In 2 Out 1 Main Right Lo L Sub Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #47 #42 (adjust Level on Out1) Options If no seperate sub signal available, use Sum L+R. MF and HF horns could be rotated for vertical use. System Applications Xi Series 2. 4 2-Way LCR+Sub Small Theatre L C R Xi 1123 Xi 1123 Xi 1123 Left Center Right Sub L: 2 x 12" L:10" + 2" R: 2 x 12 " R:10" + 2 " C: 2 x 12" C:10" + 2" R: 1 x 18 " L:1 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 3 x Xi 1123, 2 x Xi 1191 4 x P 2000 2 Horizontal coverage: Average distance: Total amp. power: 3 x 100° 20-35 meters 4, 400 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left Center #2 Main Right Sub Comments Out 1 Lo L Lo R Out 2 Hi L Hi R Out 3 Lo C Out 4 Hi C Sub Preset * #47 #47(Out1&2), #48 (route Out4 to In2) Options Preset #47 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. MF and HF horns could be rotated for vertical use. System Applications Xi Series 2. 5 2-Way LCR+Sub Small to medium venue, wide · Industrial Presentations L C R Left Center Right Sub L: 2 x 12" L:10" + 2" S: 2 x 18" S:2 x 18" C: 2 x 12" C:10" + 2" R: 2 x 12" R:10" + 2" Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 3 x Xi 2123, 4 x Xi 1191 4 x P 3000 3 x NL8 long, 3 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 3 x 100° 20-25 meters 6, 300 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left Center #2 Main Right Sub Comments Out 1 Lo L Lo R Out 2 Hi L Hi R Out 3 Lo C Out 4 Hi C Sub Preset * #49 #49(Out1&2), #50 (route Out4 to In2) Options Preset #49 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. MF and HF horns could be rotated for vertical use. P2000 may be used for Xi 2123. System Applications Xi Series 2. 6 2-Way Stereo+Sub+Side-Fill Very wide venue, Top 40 Bands Xi 1122 Xi 1122 Sub SF Left Right SF: 12" SF:2" L: 12 " L:10 " + 2 " S: 2 x 18" S:2 x 18" L: 12 " L:10 " + 2 " S: 2 x 18 " S:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 2123, 2 x Xi 1122, 4 x Xi 2181 1 x P1200, 2 x P2000, 3 x P3000 3 x NL8 long, 7 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100° + 2 x 85° 25-30 + 20-25 meters 7, 650 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left #2 Sub Comments In 2 Center Side Out 1 Lo L Sub Out 2 Hi L Out 3 Lo C Lo Si Options Out 4 Hi C Hi Si Preset * #49 #42(Out1), #35 (Out 3&4) Preset #49 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. Xi 2123 could be driven 3-way (+ P1200 + Dx38) System Applications Xi Series 3. 1 3-Way Stereo Clubs/Smaller Venues XI 1152 XI 1152 Left Right Spare Spare L: 2 " R:2 " L: 15 " R:15 " L:2 x 18 " R:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1152/64, 2 x Xi 2181 1 x P 1200, 2 x P3000 2 Horizontal coverage: Average distance: Total amp. power: 2 x 60°-120° 20-25 meters 5, 500 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #38 (change Out1 to 2181-see#42) #38 (change Out1 to 2181-see#42) Xi 1152 could be positioned for dedicated horizontal angles. System Applications Xi Series 3. 2 3-Way Stereo Clubs, Smaller Venues, Top 40 Bands Xi 1122 Xi 1122 Xi 1122 Xi 1122 Left Spare Spare Right L: 12" L:2" L: 12" L:2" L: 2 x 18 " L: 2 x 18 " L: 2 x 18 " L:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1122, 4 x XI 2181 4 x P 3000 2 x NL4 long/short, 2 x NL8 long/short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100°-160° 20-25 meters 6, 400 Watts (cont. ) * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #36 (change Out1 to 2181-see#42) #36 (change Out1 to 2181-see#42) Xi 1122 could be positioned for dedicated horizontal angles P3000 can be used through out. System Applications Xi Series 3. 3 3-Way Stereo Clubs, Smaller Venues, Top 40 Bands Xi 1152 Xi 1152 Xi 1152 Xi 1152 L: 15" L:2" R: 15" R:2" L: 2 x 18" L:2 x 18" R: 2 x 18" R:2 x 18" Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1152/64, 4 x Xi 2181 4 x P 3000 2 x NL4 long/short, 2 x NL8 long/short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100°-120° 20-25 meters 7, 900 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #38 (change Out1 to 2181-see#42) #38 (change Out1 to 2181-see#42) Xi 1152 could be positioned for dedicated horizontal angles P3000 can be used through out. System Applications Xi Series 3. 4 3-Way Stereo Clubs, Top 40 Bands Left Spare Right Spare L: 2 x 12" L:10" + 2" R: 2 x 12" R:10" + 2" L: 2 x 18 " L:2 x 18 " R: 2 x 18 " R:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 2123, 4 x Xi 2181 2 x P2000, 2 x P3000 4 x NL8 long 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100° 25 meters 7, 000 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Mid L Mid R Out 2 Hi L Hi R Out 3 Out 4 Lo L Lo R Preset * #49(Out1&2) #42(Out4, 2181) #49(Out1&2) #42(Out4, 2181) Options Preset #49 is overlapped mode for maximum vertical directivity. [. . . ] power: 2 x 120°-130°, 3 x 100° 60 meters 21, 000 Watts Dx 38 configuration * OS V1. 05, might change w/o prior notice In 1 In 2 Main Left Sub Mono Center Delay L Delay R Main Right Out 1 Sub L Sub M Sub R Out 2 Lo L Out 3 Mid L Lo C Mid R Options Out 4 Hi L Hi C Hi R Lo R Preset * #42 #49 (Out 3&4), #36 (Out1) #49 #42 Comments Preset #49 is overlapped mode for maximum vertical directivity. SPL change to 250 Hz X-Over setting. System Applications Xi Series 8. 0 Specifications X-ArrayTM Xi-Series Full-Range Three-Way Systems S p e c i f i c at i o n s Frequency Response Power Handling Long-term (LF/MF/HF, LF/HF) Sensitivity (1W/1m) Triamp (LF/MF/HF) Biamp (LF/FR) Nominal Coverage Angle Crossover Frequencies Impedance LF-FR/MF/HF: Connectors Size Height Width, Front Width, Back Depth Net weight , , F" indicates the flying Version (L-Track) Xi 1123/106F 60 Hz - 20 kHz 300/300/75 W, 300/300 W 98. 0/109. 0/11. 7 dB 101. 4/106. 7 dB 100 ° x 60 ° 250/550 Hz, 1, 760 Hz 12/16/16 2 Neutrik NL8MPR 801 mm 455 mm 317 mm 463 mm 56. 8 kg Xi 2123/106F 60 Hz - 20 kHz 600/300/75, 600/300 W 101. 4/109. 0/111. 7 dB 101. 4/106. 7 dB 100 ° x 60 ° 250/550 Hz, 1, 760 Hz 6/16/16 2 Neutrik NL8MPR 1, 007 mm 455 mm 317 mm 463 mm 70. 3 kg Xi 1183/64F 50 Hz - 20 kHz 600/300/75 W 93. 5/107. 0/112. 0 dB N/A 60 ° x 40 ° 125, 1, 760 Hz 8/16/16 2 Neutrik NL8MPR 914 mm 586 mm 354 mm 759 mm 93. 0 kg Xi 2183/64F 45 Hz - 20 kHz 1, 200/300/75 W 98. 0/107. 0/112. 0 dB N/A 60 ° x 40 ° 125 Hz, 1, 760 Hz 4/16/16 2 Neutrik NL8MPR 1, 233 mm 586 mm 354 mm 759 mm 113. 4 kg Full-Range Two-Way Systems S p e c i f i c at i o n s Frequency Response Power Handling Long-term (LF/HF - FR) Sensitivity (1W/1m) Biamp (LF/HF) Nominal Coverage Angle Crossover Frequencies Impedance LF-FR/MF/HF: Connectors Size Height Width, Front Width, Back Depth Net weight , , F" indicates the flying Version (L-Track) Low-Frequency and Subwoofer Systems Xi 1191(F) 37 - 160 Hz 600 W 94 dB 300 ° x 270 ° 125 Hz 8/NA/NA 2 Neutrik NL8MPR 914 mm 586 mm 354 mm 759 mm 68. 0 kg Xi 2181(F) 37-200 Hz 1, 200 W 98. 5 dB 240 ° x 300 ° 80-125 Hz 2 @ 8NA/NA / 2 Neutrik NL8MPR 914 mm 586 mm 354 mm 759 mm 79. 9 kg Special Purpose Systems Xi 1082 Under Balcony 50 Hz - 20 kHz 175 W 90. 0 dB 90 ° x 40 ° 3, 500 Hz (passive) 8/NA/NA Barrier Strip 488 mm 235 mm 150 mm 285 mm 13. 3 kg Xi 1122/85F 60 Hz - 20 kHz 300/75 W 99. 0/110. 0 dB 80 ° x 55 ° 1, 500 Hz 8/NA/16 2 Neutrik NL4MPR 584 mm 375 mm 199 mm 356 mm 31. 3 kg Xi 1152/64F-94F 50 Hz - 20 kHz 600/75 W 98. 0/113. 0 dB 60 ° x 40 °/90 ° x 40° 1, 500 Hz 8/NA/16 2 Neutrik NL4MPR 759 mm 450 mm 248 mm 143 mm 40. 8 kg P-SeriesTM Amplifiers S p e c i f i c at i o n s Maximum Output (1 kHz /THD = 1%) @ 8 / @ 4 / @ 8 bridged Maximum Output (20 Hz-20 kHz /THD 0. 1%) @ 8 / @ 4 / @ 8 bridged Slew Rate IMD (SMPTE), 60 Hz, 7 kHz Frequency Response Damping Factor Protection P1200 P2000 P3000 2 x 370 W / 2 x 550 W / 1 x 11000 W 2 x 560 W / 2 x 900 W / 1 x 1800 W 2 x 850 W / 2 x 1, 400 W / 1 x 2, 800 W Cooling Size Height Width Depth Net weight 2 x 350 W / 2 x 500 W / 1 x 1000 W 2 x 500 W / 2 x 800 W / 1 x 1600 W 2 x 750 W / 2 x 1, 200 W / 1 x 2, 400 W >30 V/ms >35 V/ms >40 V/ms <0. 01% <0. 01% <0. 01% 10 Hz - 30 kHz (-1 dB) 10 Hz - 30 kHz (-1 dB) 10 Hz - 30 kHz (-1 dB) >300 (internal, 1kHz) >300 (internal, 1kHz) >300 (any mode) against over-temperaure, overload, shorted outputs, RF-Interference and DC faults, excessive phase shift, excessive output voltage, excessive back EMF, in-rush current limiter, start-up/shutdown transients, infrasonic signals low AC line voltage, nonlinear signal limiter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE XI SYSTEM APPLICATIONS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE XI SYSTEM APPLICATIONS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag