If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTROLUX LAUNDRY SYSTEMS T4250. We hope that this ELECTROLUX LAUNDRY SYSTEMS T4250 user guide will be useful to you.
Lastmanuals help download the user guide ELECTROLUX LAUNDRY SYSTEMS T4250.
You may also download the following manuals related to this product:
ELECTROLUX LAUNDRY SYSTEMS T4250 DATASHEET (202 ko)
Manual abstract: user guide ELECTROLUX LAUNDRY SYSTEMS T4250INSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] Installation manual T4250 / T4350
487 14 22 21. 07 GB
Tumble dryer
3
Safety instructions
This machine is only intended for drying water-washed garments. Clothes that have been cleaned with chemicals/inflammable liquids, must NOT be dried in the machine. Remove clothes from the tumble dryer as soon as they are dry. This prevents them from becoming creased, and reduces the risk of spontaneous ignition. [. . . ] Then the air flows out through a lint filter positioned immediately in front of the ventilator. After this, the air is evacuated through the ventilator and evacuation system. It is very important that the dryer gets enough fresh air, see next section.
1
Fresh-air
Fig. 2 For maximum efficiency and the shortest possible drying time, it is important to ensure that fresh air is able to enter the room from the outside in the same volume as that blown out of the room. 3 To avoid a draught in the room, it is advisable to place the air inlet behind the dryer. The area* of the air inlet opening must be 5 times the size of the vent pipe area. The resistance in the grating/slats on the air inlet cover plate should not exceed 10 Pa (0. 1 mbar). *The area of the inlet opening is the area through which the air can flow without resistance from grating/slatted cover. Note that gratings/slatted covers often block half of the total fresh air vent area. Remember to take this into account.
2
A
5xA
XXXX X
24 05. 01 487 19
3
5xA
487 14 22 21 - 4250/4350 GB
Installation manual Evacuation system for installation of several machines with a shared evacuation pipe
Evacuation pipe
Fig. 1 It is recommended that each dryer be connected separately to a smooth air outlet pipe with the lowest possible friction. For safety reasons it is important that the dryer is connected to a smooth evacuation pipe with a 200 mm diameter. When installing several machines on shared evacuation pipe, increase the area of the pipe with each additional machine so that each dryer will be working at the same air resistance. Fig 1 and the below table show in simplified form how the evacuation pipe should look.
1
15
2
The outlet
The pipe must end outside in the open. The outlet must be protected against rain and foreign objects. In cold areas, condensation may cause frost damage to the building.
Installation in frigid laundries
In frigid laundries and where the air resistance is very low it can be a problem to reach 12°C within the given time (Error code E18 will be displayed). In this case it will be necessary to throttle the outlet air on the damper in the evacuation pipe.
Gentle bends
Fig. To keep the air flowing, ensure proper dryer operation, and minimize lint build-up in the exhaust system, never connect ducts at right angles, always use gentle bends.
The evacuation pipe diameter must not be reduced.
5 400 6 450 7 475 8 500 9 535 10 560
No. By opening / closing the damper B the static pressure at A is either lowered or raised.
1
120
Table with static pressure
The optimum air volume is achieved if the pressure is adjusted according to the table below. After the measuring is done screw the screw into the hole. Type Effect kW Static pressure Pa
A
30 B
4250 4250 4350 4350 4350 4250/4350
9 13, 5 13, 5 18 21 **
760* 660 660 435 435 435
** = Steam heated
* It can be difficult to obtain a static pressure of 760 Pa if the vent pipes are very short. In these cases the damper must be closed as much as possible. The static pressures in this table are not to be mistaken for the counter-pressure from the pressure drop curve.
487 14 22 21 - 4250/4350 GB
Installation manual Steam installation
Before start
The steam pipe must be cut off and must not be under pressure.
19
Steam
Steam 3-10 bar absolute pressure (130180°C).
5
a b
Steam forward
1. [. . . ] Measuring branch, supply pressure
23
5
6
3+4
2
1
487 14 22 21 - 4250/4350 GB
24
Installation manual
Note Because of the differences in gasinstallation regulations in European Union it is important to use the Italian-language manual in Italy and the French-language manual in France ect.
Gas pressure Ø Nozzle Nozzle pressure (Measuring branch 2) mbar
Gas installation
Tables of pressure and adjustments Heat effect: Type 4250 = 13. 5 kW Heat effect: Type 4350 = 21 kW
Countries Heat effect kW Gas type
Upper calorific value Inlet
MJ/m3 Great Britain and Ireland
mbar
13. 5
LPG GNH
126. 4 37. 4 126. 4 37. 4 126. 4 37. 4 33. 4 126. 4 37. 4 33. 4
28/37 20 28/37 20 30 18 18 30 18 18
28/37 10. 0 28/37 10. 5 30 10. 0 15. 0 30 10. 5 15. 2
1. 8 3. 1 2. 2 3. 8 1. 8 3. 1 3. 1 2. 2 3. 8 3. 8
21
LPG GNH
English speaking countries except: Great Britain, Ireland, Australia, New Zealand
13. 5
LPG GNH GNL
21
LPG GNH GNL
487 14 22 21 - 4250/4350 GB
Installation manual Electric installation
To be carried out by qualified personnel The tumble dryer must be connected to its own fuse group and pulti-pole main switch according to IEC 60947.
25
1
Connecting the cable
The cable is led through the cable gland to the terminal block and connected as illustrated. If there is a neutral conductor in the power supply line this must be connected to terminal N: Fig. 1 Gas and steam heating 3/3N connections. 3 Electric heating.
N L3 L2 L1
Demount the cover plate from the supply unit.
Gas heating Steam heating
2
Cable dimension
For calculation of the connection cable dimension, please refer to local guidelines.
Fuse group and effect
L1 L3
3
N
The sizes of the fuse group and the effect are shown on the following page.
Function check
The function check is described in the back of this manual. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTROLUX LAUNDRY SYSTEMS T4250
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.