User manual ELK PRODUCTS ELK-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELK PRODUCTS ELK-110. We hope that this ELK PRODUCTS ELK-110 user guide will be useful to you.

Lastmanuals help download the user guide ELK PRODUCTS ELK-110.


Mode d'emploi ELK PRODUCTS ELK-110
Download
Manual abstract: user guide ELK PRODUCTS ELK-110

Detailed instructions for use are in the User's Guide.

[. . . ] VOICE MESSAGES Voice messages are spoken in English, Spanish/English, or Spanish only, depending upon the switch and jumper settings. (See "Switch & Jumper Options"). Each channel has an initial cycle, followed by a repeating cycle. Tone, Intruder, intruder, leave immediately. [. . . ] Siren starts at low volume and steps to full volume in 90 seconds. Great for controls that have limited alarm current. Cutting this jumper deletes the voice message on the BA Burglar channel input. . Note: Disables ComboTrigger Siren Only On Fire. Cutting this jumper deletes the voice and Temporal Coded Bell sound on the Fire channel input, leaving a buzzer or warble. Note: ComboTrigger on +BA or -BA will still play the " Fire" message and Temporal Coded Bell. Cutting this jumper deletes the siren and Temporal Coded Bell sounds from both the Burglar and Fire channels. For Spanish Only, cut the foil jumper marked "Cut Spanish Only" located on the back of the circuit board and then open switch SW2. = = = = = = Voice Driver ELK-110 With Temporal Coded Bell APPLICATION: The ELK-110 is the first voice siren driver to include a Temporal Coded Bell Sound, which meets the ANSI standard for emergency evacuation signaling. The ELK-110 is ideal for residential and commercial alarm jobs and features two input channels, bilingual voices messages, and many unique options. Voice Driver ELK-110 Version 4. 0 With Temporal Coded Bell FEATURES: · Two Input Channels, Burglar & Fire. · Siren only, Voice only, or combined. · Bilingual Voice - English Or Spanish. · Temporal Coded Bell - ANSI standard Audible Emergency Evacuation Signaling. · MilliMiserTM - option reduces current draw for controls with limited alarm output power · ComboTriggerTM - option for single alarm output controls which have the option of steady for burglar and pulsing for fire. · VolumeStepTM - option starts the siren sound at low volume and gradually increases the volume to maximum over a 90 second time period. · Watchdog Microprocessor Monitoring. · Lifetime Limited Warranty, call for details. SPECIFICATIONS: SW4 JP1 JP2 · Nominal Operating Voltage: 10-14 Volts D. C. · Minimum Trigger Voltage: 7 Volts D. C. · Nominal Current Drain: 1. 25 Amps. · MilliMiserTM Current Drain 800 mA. · Maximum Speaker Loading: 4 Ohms. [. . . ] With these 3 connections, the Fire channel may also be activated by pulsing the -BA (BURG) input on/off in . 5 to 1. 5 second intervals. SW1 Closed Open Warble* Buzzer CUT TRACE IC2 RED Closed SW2 Open English* Add Spanish SWITCHES CLOSED 1234 Closed SW3 Open Full Volume* Volume Step ELK-110 VOICE SIREN +12V: To use the pulsing ComboTrigger feature, or to activate the +BA (BURG) or FIRE inputs from low current triggers (5 to 40 milliamps, greater than 7 Volts D. C. ), connect this optional wire to a positive (+) 12 Volts D. C. 24hr auxiliary source rated and fused for 2 Amps or greater. This wire powers the board constantly and supplies the main operating current. If the control doesn't have an auxiliary output rated 2 Amps or greater, one option is to connect this wire directly to the standby battery using a 2 Amp in-line fuse & holder for safety. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELK PRODUCTS ELK-110 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag