If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELK PRODUCTS ELK-9100. We hope that this ELK PRODUCTS ELK-9100 user guide will be useful to you.
Lastmanuals help download the user guide ELK PRODUCTS ELK-9100.
Detailed instructions for use are in the User's Guide.
[. . . ] · Selectable X-10 signal repeater functionality. · Single or Dual Commands may be programmed to turn the relay On/Off. · On-site programming of X-10 signal(s). · Manual On/Off Push Button Control. [. . . ] Do not remove the cover of the unit without first turning off the electrical supply. Except for the configuration jumpers there are no user servicable components inside.
J1 RELAYS GROUPED [Default] Both relays activate together for control of 220/240 Volts A. C. RELAYS SEPARATED Each relay can be commanded separately for control of 110/120 Volts A. C. 1 (single phase) [Default] For typical residential installations 3 (3 phase) For commercial 208 Volts A. C. /3 P power systems this must be selected. REPEATER YES [Default] Received X-10 signals will be transmitted onto both sides of a residential electrical system. Signals will be amplified to 5V P-P maximum. Note: Actual signal boost is highly dependent upon the electrical system. This feature cannot be used in the 3 phase or commercial systems. REPEATER NO Disables the repeater functionality.
J2
J3
OPERATION MANUAL CONTROL
Pressing the button on the front of the ELK-9100 sends a local signal to change the state of the relay(s). As long as Jumper J1 is set to RELAYS GROUPED, both relays will toggle. If Jumper J1 is set to RELAYS SEPARATED the relays will toggle through the four possible states of ON/OFF, OFF/ON, ON/ON, OFF/OFF with each button press.
CONTACT CLOSURE OPERATION
The relays may also be controlled from the hardwired terminal inputs located inside the unit. In the RELAYS GROUPED operation mode, if the "Trig 1 Relay" terminals are closed together (shorted), both relays will go to the "off" state. In the RELAYS SEPARATED operation each relay is individually controlled by closure (shorting) the the appropriate trigger terminals. A relay which is hardwired triggered to be "OFF" cannot be turned ON via X-10.
X-10 OPERATION
The ELK-9100 has been factory programmed to respond to X-10 House Code "C" and Unit Code "16" (in grouped mode only) and can be reprogrammed by the user to respond to other House and Unit Code(s) if desired. To restore factory default C16 code, hold the On/Off switch pressed, power up the 9100, hold switch until Circuit 2 led flashes, release switch and press once more, Circuit 2 led will go out and the 9100 is now programmed for House Code "C" and Unit Code "16". Note: the same House Code must be used for both relays.
PROGRAMMING THE X-10 CODES
For GROUPED MODE, J1 must be set to RELAYS GROUPED. With power applied, press and hold the On/Off switch until the CIRCUIT 1 LED begins flashing. From an X-10 transmitter, send an ON signal of the desired House and Unit Code, then send an OFF signal to the same House and Unit Code. The LED will stop blinking and both relays are now programmed. Example: Enter program mode, send A1 ON and then A1 OFF. You now must send A1 ON to activate both relays (Circuit 1 & 2 On). [. . . ] After disconnecting power, mount the 9100 and a 4" electrical junction box near the load. (water heater, motor, etc. ) Disconnect the existing wiring from the load and route it into the junction box. Add wiring from the junction box to the load and wire according to the diagram. ELK-9100
ELK-9100
ULTRAMATE LINE SIGNAL PUSH ON PUSH OFF CIRCUIT1 CIRCUIT2 240V - 30A HEAVY DUTY
Not Suitable for Wet Locations
BLACK
BLUE
L1
L2 GND
ORANGE
Electrical Junction Box
LOAD
4" Electrical Junction Box
RED
Electrical Circuit Breaker Panel
Remote from Load Existing Wiring to the Load
FROM BREAKER PANEL
TO (i. e. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-9100
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.