[. . . ] * Try these other fine ELK products * Magic Module Series MM443 Magic Module, 4 Input, 4 Output, Programmable MM447 Automation Controller w/Voice, Caddx Interface MV480 Recordable Voice Module, 400 Channels MKHOME1 Home Control Kit for Caddx NX Controls MK400 Starter Kit, Includes MM443 & MK485 MK485 Programming Kit, MB485, Cables, Software MK410 X-10® Transceiver Kit, Programmed MM443 iButtonTM Access Kit w/ MM443, MA100, MA101 MK420 MA100 iButtonTM `Touchkey' Reader & Interface Pack iButtonTM `Touchkeys', 10 pcs w/keyring holders MA101 MA290 Proximity / Wiegand Data Interface to MM443 MB485 Data Bus Interface, RS232 to RS485 MC100 Clock / Calendar Module for MM443 ML8 Link Interface to Caddx NX Controls MT100 Temperature Sensor Module for MM443 MM220 Magic Module, 2 Input, 2 Output, Programmable Rust Free Sirens / Speakers 1RT Speaker & Stainless Steel Enclosure 150RT Siren & Stainless Steel Enclosure 155RT Voice Siren in Stainless Steel Box Speakers & Sirens 44 Speaker, 30 W, 8 Ohm Compact Horn 45 Siren, Compact Horn, 118db 55 Voice Siren, Compact Horn M120 Siren, Single Tone, 107db, Mini Horn SP15 Speaker, 15 watt, Small Horn SP30 Speaker, 30 watt, Horn SP35 Speaker, 20 watt, Interior SP40 Speaker, 40 watt, Horn SS15 Siren, Dual Tone, 110db, Horn SS30 Siren, Dual Tone, 120db, Horn SS36 Siren, Dual Tone, 105db, Interior ECHOTM Sirens & Speakers 73 ECHO Speaker, 20 Watt, Interior 74 ECHO Dual Tone Siren, Interior 75 ECHO Voice Siren, Interior 870 ECHO Speaker, Self Amplified Siren & Voice Drivers 100 High Performance Siren Driver 110 Voice Siren Driver, English & Spanish 120 Recordable Voice Module and Siren 124 Recordable Voice Module, 4 Channels Surge Suppressors 950 Surge Suppressor, Phone & Power Line 951 Surge Suppressor, Phone - Single Line 955 Surge Suppressor, Phone - Dual Line Relay Modules 912 Compact Relay, 12 Vdc, SPDT 912B Heavy Duty Compact Relay, 12/24 Vdc, SPDT 924 Sensitive Relay, 12/24 Vdc, DPDT 941 Alarm Output Director 960 Delay Timer Relay, 1 sec. Power Products 1240 Battery, Lead Acid, 12v, 5Ah 1270 Battery, Lead Acid, 12v, 8Ah 12100 Battery, Lead Acid, 12v, 12Ah 12170 Battery, Lead Acid, 12v, 18Ah 12250 Battery, Lead Acid, 12v, 25Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1. 5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16. 5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA Accessories 129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 "B" Connectors, Unfilled, 500 pcs 902-2 "B" Connectors, Gel filled, 500 pcs 980 Telephone Line Fault Monitor 998 Warning Alarm System Decals 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes For more information contact your local Distributor or: ELK PRODUCTS, INC 828-397-4200 FAX 828-397-4415 http://www. elkproducts. com Email: info@elkproducts. com 05/03
Sensitive Relay
ELK-924 (Single) ELK-924-4 (4 Pack)
DPDT 12 or 24 VDC w/1. 2mA Trigger
APPLICATION: The ELK-924 is a sensitive relay which offers positive (+) or negative (-) trigger activation on as low as 1. 2 mA of current. [. . . ] · Packed In Reusable Poly Storage Box. · Lifetime Limited Warranty, call for details
SPECIFICATIONS:
· Operating Voltage:12 or 24 Volts D. C. · Trigger Current: 1. 2 mA @ 12 Volts D. C. · Trigger Voltage: 5 to 24 Volts D. C. · Double Form "C" Contacts Rated for: 7 Amps
@ 30 VDC, 10 Amps @ 125 VAC.
· Diode Protection Across Relay Coils. · Size: 1. 5" X 2. 75".
Features or Specifications subject to change without notice.
828-397-4200 Voice 828-397-4415 Fax http://www. elkproducts. com email: info@elkproducts. com PO Box 100 · Hwy. 70W · Hildebran, NC 28637 · USA
Instructions Printed On Inside
APPLICATIONS AND WIRING DIAGRAMS
Wire Jumper: Cut for 24V operation Relay "B" Contacts: COM and N/C are connected when ELK-924 is off (no trigger). COM and N/O are connected when ELK-924 is on.
N/O COM N/C N/O COM N/C A
Trigger Terminals: For positive (+) outputs, use +T. For negative (-) outputs, use -T.
D3
24V OPEN
B
Power Terminals: Connect to Aux. POS = "+", NEG = "-"
POS NEG -T
Control Panel
+12V
Low current "+" Alarm Output
GND
Dual Switch (Simultaneously Switches 12V DC and 120V AC)
B
N/O COM N/C N/O COM N/C
24V OPEN
24V OPEN
B
N/O COM N/C N/O COM N/C
+T
ELK-924
Relay "A" Contacts: COM and N/C are connected when ELK-924 is off (no trigger). [. . . ] Currents as high as 12A can be switched with this hookup. Note: Use heavy-gauge wire for all high current runs.
Hookup Examples for Disabling Sensitive Trigger
Control Panel
POS NEG -T +T
POS NEG -T +T
+T [. . . ]