If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELK PRODUCTS ELK-980. We hope that this ELK PRODUCTS ELK-980 user guide will be useful to you.
Lastmanuals help download the user guide ELK PRODUCTS ELK-980.
Detailed instructions for use are in the User's Guide.
[. . . ] It installs easily between the incoming telephone block and the equipment using standard 8 conductor modular cables (not supplied).
Telephone Line Fault Monitor ELK-980
FEATURES:
· Detects a Faulted Telephone Line. · Monitors Phone Line Voltage and Current. · Selectable Time Delay period on the relay. [. . . ] See label on ELK-980 for Canadian DOC Certification Number. Features and Specifications subject to change without notice.
828-397-4200 Voice 828-397-4415 Fax http://www. elkproducts. com email: info@elkproducts. com PO Box 100 · Hwy. 70W · Hildebran, NC 28637 · USA
Instructions Printed On Inside
INSTALLATION
1. Connect the ELK-980 to the incoming phone jack using a standard 8 wire full modular "male to male" phone cord (J2). Connect the security equipment using a second 8 wire cord (J1). Depending on the equipment, this cord may be identical or it may have a male plug on one end and spade terminals on the other end. Connect two (2) wires from the ELK-980 to 12 Volts D. C. To power from 24 VDC, move Jumper JP3 to the 24V position. Connect two (2) wires from the relay output to the device that is to be activated when a dead phone line is detected. Option: Power and relay connections can be made using the four (4) extra wires in modular cord J1. This requires a cord with a male plug on one end and spade terminal wires on the other. This is not possible if the security equipment requires a male plug ended cord. See FIGURES 1 and 2 below for details on the various jumper options and wiring configurations.
OPERATION
A typical on-hook phone line will measure around 48 volts. The voltage is lower during a call in process (off-hook), however the telephone instrument will then draw current on the line. [. . . ] LED should return to 1 blink per second if phone line is OK.
FIGURE 1: USING SCREW TERMINALS AND WIRES FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP2: POWER HOOKUP YES NO SET TO "NO" TO CONNECT POWER USING POS. SCREW TERMINALS JUMPER JP3: INPUT VOLTAGE THE ELK-980 CAN BE 24V 12V POWERED FROM A 12V OR 24VDC POWER SUPPLY JUMPER JP4: SUPERVISION HOOKUP ABC SET JUMPER ON "B" THIS CREATES A CLOSED LOOP ON WIRES 2 & 7 OF J1
SECURITY/PHONE EQUIPMENT
MALE PLUG MAY BE REQUIRED WITH SOME EQUIPMENT TO J1 WIRE WIRE NO. COLOR 3 BLACK 6 YELLOW 2 ORANGE 7 BLUE 4 RED 5 GREEN 1 SLATE 8 BROWN
AB C
ELK-980 Telephone Line Fault Module
JP2 YES NO 8 PIN JACK OUT J1
JP4 5 MIN 30 SEC
NEG POS N/O COM N/C POWER ALARM RELAY
JUMPER JP1: DELAY AFTER FAULT SETS TIME DELAY BEFORE RELAY OPENS AFTER LINE FAULT
K1 RELAY IS ENERGIZED WHILE PHONE LINE IS GOOD (CLOSED CIRCUIT: COM TO NC)
JP1
5 MIN 30 SEC
24V 12V JP3 8 PIN JACK IN J2
K1
3 & 6 (NOT USED) 2 & 7 (OPTIONAL) PLUG TAMPER LOOP RING TIP TELCO R1 T1 AUX POWER NEGATIVE (GND)
JP5 D7 RESET STATUS
RJ31X JACK
(ELK-950 Recommended)
R1 1
2
3
R
4
J1
J2
8 7 T1 6 5
INCOMING TELCO LINE
+12V AUX POWER 24HR N/C ZONE INPUT ALARM ZONE (COM) ZONE
T HOUSE PHONES
CORD MAY BE (MALE TO MALE) OR (MALE TO SPADE)
JP5: MEMORY RESET MOMENTARILY SHORT TO RESET LINE FAULT MEMORY
8 WIRE FULL MODULAR CABLE (MALE TO MALE)
FIGURE 2: USING WIRES IN PHONE CORD J1 FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP2: POWER HOOKUP YES NO SET TO "YES" TO HOOKUP POWER USING WIRES 3 & 6 ON J1 JUMPER JP3: INPUT VOLTAGE 24V 12V THE ELK-980 CAN BE POWERED FROM A 12V OR 24VDC POWER SUPPLY JUMPER JP4: RELAY HOOKUP ABC SET JUMPERS ON "A & C" TO CONNECT RELAY NC & COM USING WIRES 2 & 7 ON J1 (CLOSED CIRCUIT ONLY) RELAY OPENS ON FAULT
AB C
ELK-980 Telephone Line Fault Module
JP2 YES NO
JP4 5 MIN 30 SEC
JUMPER JP1: DELAY AFTER FAULT SETS TIME DELAY BEFORE RELAY OPENS AFTER LINE FAULT 5 MIN 30 SEC THESE TERMINALS ARE NOT USED IN THIS CONFIGURATION RJ31X JACK
(ELK-950 Recommended)
JP1
24V 12V JP3 8 PIN JACK OUT J1 8 PIN JACK IN J2
SECURITY/PHONE EQUIPMENT
RING TELCO TIP R1 T1 24HR N/C ZONE INPUT ALARM ZONE (COM) ZONE NEGATIVE (GND) AUX POWER +12V AUX POWER
WIRE WIRE NO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-980
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.