User manual ELKA ES 40
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELKA ES 40. We hope that this ELKA ES 40 user guide will be useful to you.
Lastmanuals help download the user guide ELKA ES 40.
Manual abstract: user guide ELKA ES 40
Detailed instructions for use are in the User's Guide.
[. . . ] Installation and operating instructions
Barriers
ES 25 ES 25HS ES 30HS ES 30 ES 40 ES 50 ES 60 ES 80
1. Contents Technical data ES 25 - ES 40 Dimensions ES 25 ES 40 Installation ES 25 ES 40 Technical data ES 50 - ES 80 Dimensions ES 50 ES 80 Installation ES 50 ES 80 Controller MO 63 Connections Further connections Visual indication Operating mode MO 63 Photo-cell test Programming Running time and automatic closure Setting personal code for radio remote External connections Layout in the barrier Fault finding Examples for use of loop detectors Maintenance Radio remote control Extra equipment (swinging support, folding boom) General notes to safety page 2 2 3 4 4 5 6 6 7 7 8 9 9 9 10 10 11 12 14 16 16 17 19
Seite 1
© 03. 10. 2001 ELKA-Torantriebe GmbH & Co. Betriebs KG ES 25 ES 40 mit MO63
1.
Technical data ES 25- ES 40
General Data Mains supply Max. current Duty cycle Temperature range Controller Measurements (w/l/h) Foundation (frost-proof) Boom connector Housing Mechanical parts 230V / 50Hz 2, 5A 100% -20°C to +70°C MO 63 350x300x1100 mm 550x500x800 mm left or right aluminium steel, zinc coated
Operative range Application - Parking area, parking garage for . . . [. . . ] Betriebs KG
B3: socket for 1- or 2-channel detector If a detector is used, remove the red jumper.
loop 1: 1-channel detector for safety and closing loop 1: 2-channel detector for safety and closing loop 2: 2-channel detector for opening If a 1-channel detector is used, remove the jumper between 27b-6b. If a 2-channel detector is used, remove the jumper between 25b-25t and set operating mode switch 8 ON. If loop 2 is used for presence, do not remove the jumper between 25b-25t. Set push button between 27b and 6b.
B2: socket for 1-channel detctor loop 3: 1-channel detector for opening
page 11
ES 25 ES 80 (MO63)
9. The closed barrier doesn't react to a signal to open Possible cause
No mains supply. The controller is switched off.
Symptom
The yellow power LED is out. The red diagnostic LED flashes non-stop. The green LED BTS1 is lit.
Possible solution
Check the mains lead and the fuses. b) Switch On/Off switch (X1/4 top and X1/4 bottom off). Release the button (X1/8 top and bottom). Replace the limit switch.
The green LED BTS2 is out.
a) The stop button is pressed.
b) Emergency release in use. The green LED SEA is out and the a) Faulty limit switch 'open`. red Diag. -LED flashes 4 times then a break. b) Wiring faulty The green LED BTZ1 is lit. There is a permanent signal to close.
Check the wiring to the limit switch and plug V6 on the controller. Check the button (X1/2 bottom/top and 7 top).
When the controller gives an error code through the red Diag. -LED see the chapter 9. 4.
9. 2.
The open barrier doesn't react to signals to close Possible cause
No mains supply. b) The red jumper is removed from the terminals 6 and 10 in socket B3, but the loop detector hasn't been inserted. The photo-cell is connected as normally open. There is a permanent signal to open.
Symptom
The yellow power LED is out. The red diagnostic LED flashes non-stop The green LED LS is lit.
Possible solution
Check the mains lead and the fuses. Plug the detector into the socket B3 or replace the red jumper.
The green LED LS is lit when the photo-cell is free, and not lit when an obstacle is present The green LED BTA is lit.
Check it (X1/9 top and X1/9 bottom). Connect the photo-cell as normally closed. [. . . ] It should be read thoroughly by all persons who use, or service the appliances. Improper usage or servicing or ignoring the operating instructions can be a source of danger for persons, or result in material damage. If the meaning of any part of these instructions isn't clear, then please contact ELKA Torantriebe GmbH & Co. Betriebs KG before you use the appliance. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ELKA ES 40 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELKA ES 40 will begin.