User manual ELKA SYNTHEX SCHEMATIC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELKA SYNTHEX. We hope that this ELKA SYNTHEX user guide will be useful to you.

Lastmanuals help download the user guide ELKA SYNTHEX.


Mode d'emploi ELKA SYNTHEX
Download
Manual abstract: user guide ELKA SYNTHEXSCHEMATIC

Detailed instructions for use are in the User's Guide.

[. . . ] - Company entrance - Safety area - Toll-station Drive pulse - Push-button, card reader, key switch, from . . . - Handsfree data-capture - Induction loop Safety - Reversing on obstacle - Best protection against vandalism - Ergonomic emergency release Typical Data Drawn power Running time Maximum boom length Effective length Reversing on obstacle Boom weight / Barrier weight ES 25 * 0. 37 kW ca. 1. 4 s 2500 mm 2280 mm switchable 4 / 2 kg 47. 5 kg ES 25 HS * 0. 37 kW ca. 0. 9 s 2500 mm 2280 mm switchable 4 / 2 kg 47. 5 kg ES 30 HS * 0. 37 kW ca. [. . . ] 3 seconds ­ the red Diag. -LED starts flashing. Keep the learn button pushed for approx. The red Diag. -LED lights for 2 seconds ­ the personal code is erased and the learning is finished. 7. External connections For the power supply of the external equipment (e. g. photo-cells, induction-loops. . . . ) the controller provides stabilised 24 Vdc and 12 Vdc. 500 mA can be drawn from the 12 V source and the 24 V source, but together max. The supply of the photo-cell transmitter during photo-cell test comes from the 24 V source and has to be considered. red jumper loop 1 (B3/1) loop 2 (B3/2) loop 3 (B2) Barrier open (green light) Barrier moving, or about to move (amber, or flashing light) Barrier closed (red light) Photo-cell X1/9t X1/9b Stop X1/8t X1/8b No boom (option) Boom open Boom closed ON / OFF Serial switching Barrier open Barrier close Important instructions when using loops for safety and closing When using a loop-detector for safety remove the red junper between contects 6 and 10 on the socket B3. The socket B3 is always for the loop under the barrier boom, and is prewired for safety and for closing when leaving the loop. When B3 is equipped with a 2-channel-detector, the second channel may be used for an opening loop or a loop detecting that a vehicle is present. The socket B2 is prewired for an opening loop in connection with a 1-channel-detector. Please see chapter 10 "Examples for use of loop detectors". b) The red jumper is removed from the terminals 6 and 10 in socket B3, but the loop detector hasn't been inserted. The photo-cell is connected as normally open. There is a permanent signal to open. Symptom The yellow power LED is out. The red diagnostic LED flashes non-stop The green LED LS is lit. Possible solution Check the mains lead and the fuses. Plug the detector into the socket B3 or replace the red jumper. The green LED LS is lit when the photo-cell is free, and not lit when an obstacle is present The green LED BTA is lit. Check it (X1/9 top and X1/9 bottom). Connect the photo-cell as normally closed. a) Check the 'open` button (X1/2 bottom and X1/6 top) b) Check the loop detector in socket B2 Replace the limit switch. The green LED SEZ is out and the a) Faulty limit switch 'closed`. red diagnostic LED flashes 4 times ­ then a break. The green LED BTZ2 is lit. Check the wiring and plug V6 in the control box. There is a permanent signal to the Check the button (X1/7 bottom and terminals BTZ2. X1/2 bottom/top) When the controller gives an error code through the red Diag. -LED see the chapter 9. 4. © 26. 07. 2006 ELKA-Torantriebe GmbH u. [. . . ] Push the rubber tube into the slot and cut off the protruding part. A fine adjustment of the length can now be made on the foot 'D'. Screw a 4 mm screw into the hole `E'. d) e) f) g) The foot can now be screwed to the appropriate position. A2 11 21 14 top 1 14 bottom bottom 2 top Magnet © 26. 07. 2006 ELKA-Torantriebe GmbH u. Betriebs KG page 18 ES 25 ­ ES 80 (MO63) 14. General notes of safety These operating instructions must be available on site at all times. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELKA SYNTHEX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELKA SYNTHEX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag