User manual EMERSON FANS MIDWAY II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON FANS MIDWAY II. We hope that this EMERSON FANS MIDWAY II user guide will be useful to you.

Lastmanuals help download the user guide EMERSON FANS MIDWAY II.


Mode d'emploi EMERSON FANS MIDWAY II
Download
Manual abstract: user guide EMERSON FANS MIDWAY II

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS ® MIDWAY IITM 54" Ceiling Fan Owner's Manual Net Weight: Model No. 23. 8 Lbs. CF929BS 00 CF929WW 00 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. Repair and replacement of defective parts on the light fixture housing or electronics (excluding the lamp) for two years from the date of purchase. [. . . ] Pull on the downrod to make sure the clevis pin is properly installed. ! Figure 3 5. Reinstall the hanger ball (Figure 4) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. ! WARNING WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling. It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. PIN HANGER BALL SETSCREW DOWNROD DOWNROD HAIRPIN CLIP SETSCREW CLEVIS PIN CEILING COVER Figure 4 Figure 2 MOTOR COUPLING 6. The fan comes with blue, black and white leads that are 80" long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. Turn fan assembly upside down in preparation for mounting fan blade assemblies. 3. While pulling up on the downrod, securely tighten the setscrew in the motor coupling (Figure 3). Attach the lower housing assembly to the fan motor using the two key slot holes. Secure the lower housing assembly by tightening the two screws. Reinstall the two screws that were removed. NOTE: Make sure wires and terminals are positioned in raised center area of lower housing assembly, and not pinched between fan and light kit. LOWER HOUSING ASSEMBLY The fan must be hung with at least 7' of clearance from floor to blades (Figure 8). CEILING AT LEAST 7' Figure 8 ! FLOOR RAISED CENTER AREA OF LIGHT KIT HOUSING SCREWS (2) KEY SLOT HOLE (2) WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. Figure 7 5 ! WARNING How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. Your ceiling fan is supplied with an Emerson Fan/Light Control. Wire your ceiling fan in accordance with the Owner's Manual supplied with the Fan/Light Control. After splices have been made, carefully push splices up into the outlet box. ! To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. 1. [. . . ] Check to make sure the screws which attach the fan flanges to the motor are tight. Raise coupler cover and tighten the setscrew securely. Tighten the setscrew in the hanger ball/downrod assembly. Check to be sure screws which attach the fan blade flanges to the motor are tight. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS MIDWAY II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS MIDWAY II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag