User manual EMERSON HD13002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON HD13002. We hope that this EMERSON HD13002 user guide will be useful to you.

Lastmanuals help download the user guide EMERSON HD13002.


Mode d'emploi EMERSON HD13002
Download
Manual abstract: user guide EMERSON HD13002

Detailed instructions for use are in the User's Guide.

[. . . ] HD1300 3 US manual 11/14/00 1:40 PM Page 1 CAUTION: Read all instructions carefully before installation. Save this Owner's Manual for future reference. Model No. HD1300 3 EMERSON MoistAIRTM HD1300 Evaporative Console Humidifier Owner's Manual Part No. SP6305 ® Printed in Canada HD1300 3 US manual 11/14/00 1:40 PM Page 2 Limited Warranty All products covered by this Owner's Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years. [. . . ] Familiarize yourself with the controls and reference the diagram of the control area for the correct naming used within this manual. Fan Control Your Emerson humidifier allows a choice to be made for single or dual fan control. The slide switch located closest to the front of the cabinet allows one or two fans to be used. Slide the switch to the "1" position to operate one fan and the "2" position to operate both fans. The "FAN" slide switch, positioned in the #1 position will operate the humidifier with one fan only in any speed position and provides reduced output at a lower noise level. The "FAN" slide switch positioned in the #2 setting will operate the humidifier with both fans and provides greater output than the single fan settings. Maximum output is provided by the humidifier in the #2 position with the speed control set at high. This combination of infinite number of fan/speed settings allows you to determine the noise level and output level that best suits you. To Operate the Controls Humidity Control: Adjust the amount of humidity depending on your needs. The humidifier will turn on and off as required to maintain level of humidity selected. A medium setting (half way between MIN and MAX) is recommended, but there are times when a low or high amount of humidity may be preferred. For constant operation of humidifier, MAX allows for the maximum amount of humidity to be evaporated into the air continuously. IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humid ity MIN MAX Relative Humidity Operating Tips for Best Performance 1. Position the humidifier at least 2 inches from any wall and away from any heat registers. Do not restrict airflow from entering or exiting the humidifier. Use Emerson recommended bacteriostat WT-BC to retard bacteria growth that may cause odors and may be harmful to your health. Regular cleaning as instructed in "Cleaning Your Humidifier" section of this manual is recommended. Replace the evaporative wicking filters at least once per humidification season or more depending on water conditions in your area. 8 HD1300 3 US manual 11/14/00 1:40 PM Page 9 Replacement and Care of Filters WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: To help retard bacteria growth and keep maximum efficiency, the filters should be replaced at least once a season, or more often under hard water conditions. Use Emerson HDC-12 recommended replacement filter. All filters may be rinsed in clear water only. To replace the evaporative wicking filters in your Emerson humidifier, follow the instructions below. Unplug humidifier, and proceed to clean. [. . . ] Follow bi-weekly maintenance instructions at end of humidification season. Let humidifier dry completely before storing. Install new filters into a clean humidifier before next season begins. "Bi-Weekly Maintenance" is also recommended if you do not plan to run the humidifier for one week or more. 12 HD1300 3 US manual 11/14/00 1:40 PM Page 13 Troubleshooting TROUBLE PROBABLE CAUSE REMEDY · Raise humidistat setting if desired · Check 120 volt source for power Unit will not run · Selected humidity level has been established and Fill Light is · No power not illuminated. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON HD13002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON HD13002 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag