User manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP. We hope that this ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP user guide will be useful to you.
Lastmanuals help download the user guide ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP.
Manual abstract: user guide ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP
Detailed instructions for use are in the User's Guide.
[. . . ] Operating Instructions
Proline t-mass 65 PROFIBUS DP
Thermal Mass Flow Measuring System
8
BA113D/06/en/02. 06 71021608 Valid as of version V 3. 02. XX (Device software)
Proline t-mass 65 PROFIBUS DP
Table of contents
Table of contents
1
1. 1 1. 2 1. 3 1. 4 1. 5
Safety instructions . Installation, commissioning and operation . 4. 2. 1 Connecting connecting cable for sensor/transmitter . 4. 2. 2 Cable specification, connecting cable . [. . . ] HOLD VALUE: The totalizer remains at the last value.
!
Note!The device can't calculate negative flow portions.
53
Commissioning
Proline t-mass 65 PROFIBUS DP
7.
Select the operating mode: Select the operating mode (GSD file) which should be used for cyclic data transmission with the PROFIBUS Master. COMMUNICATION SELECTION GSD Selection of one of the following options: MANUFACT. (factory setting): the complete device functionality is available. PROFILE-GSD: The device is operated in the PROFIBUS Profile mode.
!
Note!For PROFIBUS network configuration, make sure that the right device master file (GSD file) of the measuring device is used for the selected operating mode Page 54 ff. Configuration of cyclic data transmission in the PROFIBUS master: A detailed description of the cyclic data transmission is contained on Page 57 ff.
6. 5
6. 5. 1
PROFIBUS DP system integration
Device master file (GSD file)
For PROFIBUS network configuration, the device master file (GSD file) is needed for every bus participant (PROFIBUS slave). The GSD file contains a description of the properties of a PROFIBUS device, such as supported data transmission rate and number of input and output data. Before configuration takes place, a decision should be made as to which GSD file should be used to operate the measuring device in the PROFIBUS DP Master (class 1) system. The measuring device supports the following GSD files: t-mass GSD file (manufacturer-specific GSD file, complete device functionality) PROFIBUS Profile GSD file: Below you will find a detailed description of the GSD files supported. t-mass GSD file (manufacturer-specific GSD file, complete device functionality) Use this GSD file to access the complete functionality of the measuring device. In this way, devicespecific measured variables and functions are thus completely available in the PROFIBUS master system. An overview of the modules available (input and output data) is contained on Page 57 ff. GSD file with standard or extended format The GSD file with either the standard or the extended format must be used depending on the PROFIBUS Master used. When installing the GSD file, the GSD file with the extended format (EH3x15xx. gsd) should always be used first. However, if the installation or the configuration of the measuring device fails with this format, then use the standard GSD (EH3_15xx. gsd). This differentiation is the result of different implementation of the GSD formats in the master systems. Note the specifications of the PROFIBUS Master. PROFIBUS DP 1545 (Hex) GSD file Bitmaps
Extended Format (recommended): EH3x1545. gsd EH_1545_d. bmp/. dib Standard Format: EH3_1545. gsd EH_1545_n. bmp/. dib EH_1545_s. bmp/. dib
Source Internet (Endress+Hauser) www. endress. com ( Download Software Device Drivers) CD-ROM with all GSD files for Endress+Hauser devices Order No. : 56003894
54
Proline t-mass 65 PROFIBUS DP
Commissioning
Contents of the download file from the Internet and the CD-ROM All Endress+Hauser GSD files (standard and extended format) Endress+Hauser bitmap files Useful information relating to the devices PROFIBUS Profile GSD file: The function scope of the profile GSD file is defined by the PROFIBUS Profile Specification 3. 0. The function scope is restricted compared to the manufacturer-specific GSD file (complete device functionality). However, similar devices from different manufacturers can be interchanged with the profile GSD file without the need to reconfigure (interchangeability). The following modules are supported with the Profile GSD file: "AI Flow" module Analog Input function block 1/output variable: mass flow "Totalizer" module Totalizer function block 1/output variable: totalized mass flow Name of the PROFIBUS Profile GSD file
ID No. [. . . ] 96 Printed circuit boards (installation/removal) Field housing . 43
103
Proline t-mass 65 PROFIBUS DP
Index
PROFIBUS DP cyclic data transmission AI (Analog Input) module. .
T
59 63 62 62 63 63 60 59 39 T-DAT Save/Load . 92 Temperature ranges Ambient temperature range . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP will begin.