User manual ENERGIZER ER-OF1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ENERGIZER ER-OF1000. We hope that this ENERGIZER ER-OF1000 user guide will be useful to you.

Lastmanuals help download the user guide ENERGIZER ER-OF1000.


Mode d'emploi ENERGIZER ER-OF1000
Download
Manual abstract: user guide ENERGIZER ER-OF1000

Detailed instructions for use are in the User's Guide.

[. . . ] Because the number of computer peripherals increase, additional surge protected outlets are provided to protect your printer, scanner or other peripheral devices from surges, spikes, and electromagnetic interference. Your box should include the following: UPS unit and Input Power Cord User's Manual Telephone Line Communication Connection Cord Remote Monitoring Software Specifications Color Run Time Surge Protected vs. Battery Backup Outlets Warranty Internet Ready/Phone/Fax Modem hookups VA Rating Watts Input/Output Voltage Frequency Interface Port (USB or Serial) Black 5 to 42 minutes 4:4 3 years RJ11/RJ45 1000 400 115 60 RJ48 (USB and Serial) Waveform Type Joules (surge capacity) Overload Protection Recharge Time (typical) Visual Indicators (lights) Audible Indicators Connected Equipment Guarantee Unit Dimensions/Weight Compliance Cord Length Stepped Sinewave 748 Yes <=8hrs of 90% 4 4 3 years 13. 4 x 3. 4 x 6. 1 CUL 6 feet Features: Compact light weight design Intelligent microprocessor control Unparalleled communication with your computer Provides accurate information for control and monitoring power Overload protection and alarm Smart AVR for low and high input line voltage Fax/modem surge suppression port Site-Wiring-Fault indicator Easy battery replacement mechanism 1 2 3 AC BATT Item Panel Indicator On/Off Switch AC Normal/On Battery Indicator (green) Buck Mode Indicator (yellow) Boost Mode Indicator (yellow) Overload/Abnormal Indicator (red) Input Circuit Breaker Description Turns UPS system on & off Indicate the AC is normal or that the UPS is in battery mode Measures and restores normal AC voltage if it is too high Measures and restores normal AC voltage if it is too low Indicates the UPS output is overloaded or that there is UPS failure Protect against UPS system overload Provide output power to computer device Provides a noise filtering function to computer peripherals Allows remote monitoring and control via serial interface ports Suppress the spoke voltage on the telephone line Connects to input utility power through the input power cord. Indicate missing ground or polarity reversed 1 2 3 4 5 6 7 9 12 4 5 BUCK BOOST OVERLOAD 10 SITE WIRE FAULT INTERFACE Backup Power Outlets Surge Protection Outlets IN FAX/MODEM OUT 8 8 SURGE PROTECTION BACKUP POWER OUTLET 9 RF48 port Telephone Surge Protection Port AC Power Input Site Wire Fault Indicator (red) 7 6 CIRCUIT BREAKER AC INPUT 10 11 11 12 Installation 2 SITE WIRE FAULT DATA PORT Plug your modem or fax line into the UPS "OUT" line and your computer into the "IN" line. IN FAX/MODEM OUT 1 Plug your EnergizerÆ ER-OF1000 UPS Power Protection system into a wall outlet. SITE WIRE FAULT DATA PORT SURGE PROTECTION BACKUP POWER OUTLET IN FAX/MODEM OUT SURGE PROTECTION BACKUP POWER OUTLET CIRCUIT BREAKER AC INPUT Computer phone line to UPS IN plug CIRCUIT BREAKER AC INPUT Modem or fax line to UPS OUT plug 3 Plug all equipment to the plugs in the back of the UPS. SITE WIRE FAULT DATA PORT 4 Insert FileSaver software in CD-ROM drive on computer and follow instructions. IN FAX/MODEM OUT SURGE PROTECTION BACKUP POWER OUTLET Use your battery backup sockets for: computer, monitor, and external storage devices (i. e. For surge protection, plug in: non-essential equipment such as printers, scanners, and speakers. printer speaker CIRCUIT BREAKER AC INPUT computer monitor Do NOT use your UPS for: laser printers, vacuums, space heaters, copiers, or shredders. Troubleshooting Problem UPS will not turn on; LED is not lit. Cause Your On/Off switch was not pushed in completely. [. . . ] Available backup time is less than the indicated rating. Your computer input power cord is loose or disconnected. Your battery is not fully charged or your battery is dead. Your UPS system is slightly overloaded. The UPS system is continually beeping. Your UPS system is overloaded. Your UPS system has automatically defaulted to battery mode. The Site Wiring Fault LED is on. Your communication function is not working. Your polarity is reversed or another electrical issue. You are using the wrong interface cable. For any additional questions, or questions concerning the FileSaver software, please visit www. energizerups. com or call 1-877-267-4687 Warranty What does the warranty cover?We warrant this product to be free from defects in material and workmanship during the warranty period. If a product proves to be defective in material or workmanship during the warranty period, we will, at our option, repair or replace the product with an equivalent model. EnergizerÆ Power Protection products are warranted for 3 years for all parts and labor from the date of the first consumer purchase. Any product on which the serial number has been defaced, modified or removed. Damage, deterioration or malfunction resulting from: accident, misuse, neglect, fire, water, lightening, or other acts of nature, unauthorized product modification, or failure to follow instructions supplied with the product. Repair, or attempt to repair, by anyone who is not authorized. Any damage of the product that occurred during shipping. Any damage that results from the installation of the product. Use of supplies or parts not meeting indicated specifications. Any other cause which does not relate to a product defect. Servicing and Replacing the Battery Routine Maintenance: Use dry soft cloths to clean the front panel and plastic parts. Do not use any detergent that contains any alcohol ingredient. [. . . ] For extended storage in moderate climates, the battery should be charged for 12 hours every three (3) months by plugging the power cord into the wall outlet and turning on the main switch. Repeat every two (2) months in high temperature locations. Can I use this product for life support?We do not recommend the use of our products for life support equipment or direct care where failure of the product could cause failure or diminished effectiveness of the life support equipment or patient care. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ENERGIZER ER-OF1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ENERGIZER ER-OF1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag