Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ESYSCO KT-22X0. We hope that this ESYSCO KT-22X0 user guide will be useful to you.
Lastmanuals help download the user guide ESYSCO KT-22X0.
Detailed instructions for use are in the User's Guide.
[. . . ] COMMUNICATIONS ------------------------------------------------- 6 6. TRANSMISSION PROTOCOL ------------------------------------ 8 7. DIMENSIONS --------------------------------------------------------- 14
ESYSCO AG
www. esysco. com
ESYSCO AG S e n n w e i d s t ra s s e 4 5 CH-6312 Steinhausen
Tel. +41 41 7401330 Fax +41 41 7401335 in fo @ e s y sc o . c h
DOC. [. . . ] Card Feeding Speed : 20 to 120 cm/sec 3. 4. 2. RS-232-C Interface RS-232-C Host PC KT-22X0 Signal Direction Signal Name 9 Pin 9 Pin Host PC KT-22X0 TXD 3 2 >>>>> RXD 2 3 <<<<< RTS 7 7 >>>>> SG 5 5 DTR 4 4 >>>>> - 9 Pin female D-sub connector : KT-22X0 - Transmission Distance : Max. Baud Rates SW2 SW1 Baud Rate On On 9600 Off On 4800 On Off 2400 Off Off 1200 - Default : 9600 Baud Rate 4. 2. 2. Parity Settings SW4 SW3 Parity On Off Odd Parity Off Off Even Parity On On No Parity Off On No Parity - Default : Even Parity 4. 2. 3. Data Length Settings SW5 Data Bits On 8 Bits Off 7 Bits - Default : 7 Bits 4. 2. 4. Model Settings SW8 SW7 SW6 Model On On Off KT-2210 On Off On KT-2220 On Off Off KT-2230 Off On Off KT-2250 Off Off On KT-2260 Off Off Off KT-2280 - These settings should not be changed by the user
ESYSCO AG
www. esysco. com
ESYSCO AG S e n n w e i d s t ra s s e 4 5 CH-6312 Steinhausen
Tel. +41 41 7401330 Fax +41 41 7401335 in fo @ e s y sc o . c h
DOC. NO.
CT-302
KT-2200 SPECIFICATIONS
REV.
C
PAGE
6 OF 14
DATE
2000. 02. 14
5. Transmission Type : Asynchronous, Half duplex 5. 1. 2. Baud rate : 1200, 2400, 4800, and 9600 5. 1. 4. Mode Control The reader operates in two basic modes, READY MODE and HOST CONTROLLED MODE. Upon applying power to the reader, LEDs are lit for 250m secs, and buzzer beeps for 250m secs. READY MODE When power is first applied, the reader defaults to this mode, in which it arms itself to read. When a card is swiped readers send the data ( no start / end sentinel or LRC ) preceded by a track identifier and followed by CR. No data is sent to the host when an error block track is found. The Card Reader transmit the lower track first, which is Track I , Track II, Track III . Single Track Reader Result Buzzer (msec) Good 250 Error ERROR BEEP
Green LED (msec) 250
Red LED (msec) 800
Dual or Triple Track Reader Result Buzzer (msec) Green LED (msec) T1 OR T2 OR T3 Good 250 250 ALL Track error ERROR BEEP * ERROR BEEP : On Off On Off On 200 100 200 100 200 (msec)
Red LED (msec) 800
After terminating the transmission and the LED and buzzer indications, the reader rearms itself to read. Track I Track II Track III : " % " ( 25h ) : " ?" ( 3Fh ) : " ^ " ( 5Eh )
ESYSCO AG
www. esysco. com
ESYSCO AG S e n n w e i d s t ra s s e 4 5 CH-6312 Steinhausen
Tel. +41 41 7401330 Fax +41 41 7401335 in fo @ e s y sc o . c h
DOC. [. . . ] NO.
CT-302
KT-2200 SPECIFICATIONS
REV.
C
PAGE
10 OF 14
DATE
2000. 02. 14
6. 2. 2. Arm to Read (Do not transmit status report)
Host
KT-22X0
<STX>A<ETX><BCC> ----------> <---------- <STX><ACK><ETX><BCC> ( Card Swipe ) <STX>M<ETX><BCC> ----------> <---------- <STX>g<ETX><BCC> <STX>J<ETX><BCC> ----------> <---------- <STX><Track #1 Data><ETX><BCC> or <STX> * <ETX><BCC> <STX><ACK><ETX><BCC> ----------> <STX>K<ETX><BCC> ----------> <---------- <STX><Track #2 Data><ETX><BCC> or <STX> * <ETX><BCC> <STX><ACK><ETX><BCC> ----------> <STX>L<ETX><BCC> ----------> <---------- <STX> <Track #3 Data><ETX><BCC> or <STX> * <ETX><BCC> <STX><ACK><ETX><BCC> ---------->
6. 3. Control LED and BUZZER
Host
KT-22X0
<STX>D<ETX><BCC> or <STX>E<ETX><BCC> ----------> <---------- <STX><EOT><ETX><BCC> ( Turn buzzer on for 250 or 200msec 3 times ) <STX>F<ETX><BCC> or <STX>G<ETX><BCC> ----------> <---------- <STX><EOT><ETX><BCC> ( Turn green/red LED on for 250 or 800msec)
ESYSCO AG
www. esysco. com
ESYSCO AG S e n n w e i d s t ra s s e 4 5 CH-6312 Steinhausen
Tel. +41 41 7401330 Fax +41 41 7401335 in fo @ e s y sc o . c h
DOC. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ESYSCO KT-22X0
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ESYSCO KT-22X0 will begin.